HL incident on 2025-10-15 — TX
Operator
Scm Pr, Llc
Cause
Equipment Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$50
Incident datetime
2025-10-15 14:30
Report number
Location
TX
Narrative
Station operator arrived at 14:30 pm on 10/15/2025 for a station check and discovered that release from a needle valve was in progress. This is a 1/2� needle valve on the alternate test port fitting on the tank manifold inlet surge relief valve. Failure resulted in a 36-gal release of crude. As a permanent containment and repair, 1/2� fitting and ball valve was installed to replace the needle valve. Some of the needle valve was missing. Being a small part, it was not found and probably sucked up when the hydrovac operations were being conducted to remove the contaminated soil. Therefore, it is unknow how the needle valve failed. This was not a piece of equipment that is remotely monitored and the small volume of discharge would not have been detected from the operations center.
Detailed record list
Report Received Date
2025-11-11 00:00:00
Iyear
2025
Report Number
20250260
Supplemental Number
41583
Report Type
Supplemental
Operator Id
39822
Name
Scm Pr, Llc
Operator Street Address
909 Lake Carolyn Parkway Suite 650
Operator City Name
Irving
Operator State Abbreviation
TX
Operator Postal Code
75039
Local Datetime
2025-10-15 14:30:00
Time Zone
Mountain
Daylight Savings Ind
Yes
Location Latitude
43.34798
Location Longitude
-105.57534
Commodity Released Type
Crude Oil
Unintentional Release Bbls
0.9
Recovered Bbls
0.9
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2025-10-15 14:30:00
System Part Involved
Onshore Terminal/tank Farm Equipment And Piping
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
No
Shutdown Explain
Shut Down Unnecessary As Leak Was Stopped And Failed Equipment Was Replaced.
Communication State Fed Ind
No
On Site Datetime
2025-10-15 14:30:00
Confirmed Discovery Datetime
2025-10-15 14:30:00
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Notify Qualified Indiv Ind
Yes
Qualified Indiv Notif Datetime
2025-10-15 14:30:00
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Converse Station
Segment Name
Alt Test Port On Surge Relief Valve To Bo Tanks
Onshore State Abbreviation
Wy
Onshore Postal Code
82633
Onshore City Name
Not Within A Municipality
Onshore County Name
Converse
Designated Location
Survey Station No.
Designated Name
Converse Stat
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Valve
Valve Type
Auxiliary Or Other Valve
Installation Year
2018
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Other
Leak Type Other
Alt Test Port Needle Valve
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
54
Est Cost Prop Damage
50
Est Cost Emergency
1345
Est Cost Environmental
0
Est Cost Other
0
Prpty
1449
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
50
Mop Psig
559
Mop Cfr Section
Internal Design Pressure �195.406(A)(1)
Maop Established Date
2021-04-23 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
Yes
Exceed Restriction Ind
No
Phmsa Restriction Ind
Not Mandated
Pipeline Function
< 20% Smys Regulated Transmission
Scada In Place Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
This devices is not designed to be remotely monitored and leak detection would not detect this small amount, so incident did warrant an investigation of the control room.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Other Equipment Failure
Eq Failure Type
Other Equipment Failure
Failure Details
Alternate Test Port Fitting Needle Valve Failed
Additional Erosion Wear Ind
Yes
Eq Additional Other Ind
Yes
Eq Additional Other Details
No Able To Identify Additional Factor-Needle Vlv Part Was Sucked Up By Hydrovac.
Eqf Defective Fitting Ind
Yes
Preparer Name
M*** P*****
Preparer Title
Regulatory And Safety Director
Preparer Email
M******@s**********.com
Preparer Telephone
4696142257
Prepared Date
2025-11-13 00:00:00
Local Contact Name
J****** "***** N******
Local Contact Email
N*******@s**********.com
Local Contact Telephone
307-315-3374
Authorizer Name
M*** P*****
Authorizer Telephone
4696142257
Authorizer Title
Regulatory And Safety Director
Authorizer Email
M******@s**********.com
Narrative
Station operator arrived at 14:30 pm on 10/15/2025 for a station check and discovered that release from a needle valve was in progress. This is a 1/2� needle valve on the alternate test port fitting on the tank manifold inlet surge relief valve. Failure resulted in a 36-gal release of crude. As a permanent containment and repair, 1/2� fitting and ball valve was installed to replace the needle valve. Some of the needle valve was missing. Being a small part, it was not found and probably sucked up when the hydrovac operations were being conducted to remove the contaminated soil. Therefore, it is unknow how the needle valve failed. This was not a piece of equipment that is remotely monitored and the small volume of discharge would not have been detected from the operations center.
| Report Received Date | 2025-11-11 00:00:00 |
|---|---|
| Iyear | 2025 |
| Report Number | 20250260 |
| Supplemental Number | 41583 |
| Report Type | Supplemental |
| Operator Id | 39822 PHMSA Enforcement |
| Name | Scm Pr, Llc |
| Operator Street Address | 909 Lake Carolyn Parkway Suite 650 |
| Operator City Name | Irving |
| Operator State Abbreviation | TX |
| Operator Postal Code | 75039 |
| Local Datetime | 2025-10-15 14:30:00 |
| Time Zone | Mountain |
| Daylight Savings Ind | Yes |
| Location Latitude | 43.34798 Google Maps OpenStreetMap |
| Location Longitude | -105.57534 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 0.9 |
| Recovered Bbls | 0.9 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Local Operating Personnel, Including Contractors |
| Operator Type | Operator Employee |
| Incident Identified Datetime | 2025-10-15 14:30:00 |
| System Part Involved | Onshore Terminal/tank Farm Equipment And Piping |
| On Off Shore | Onshore |
| Status When Identified | Normal Operation, Includes Pauses Between Batches And During Maintenance |
| Shutdown Due Accident Ind | No |
| Shutdown Explain | Shut Down Unnecessary As Leak Was Stopped And Failed Equipment Was Replaced. |
| Communication State Fed Ind | No |
| On Site Datetime | 2025-10-15 14:30:00 |
| Confirmed Discovery Datetime | 2025-10-15 14:30:00 |
| Nrc Rpt Num | Nrc Notification Not Required NRC Report How to search |
| Ignite Ind | No |
| Notify Qualified Indiv Ind | Yes |
| Qualified Indiv Notif Datetime | 2025-10-15 14:30:00 |
| Oil Spill Removal Org Ind | No |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Converse Station |
| Segment Name | Alt Test Port On Surge Relief Valve To Bo Tanks |
| Onshore State Abbreviation | Wy |
| Onshore Postal Code | 82633 |
| Onshore City Name | Not Within A Municipality |
| Onshore County Name | Converse |
| Designated Location | Survey Station No. |
| Designated Name | Converse Stat |
| Federal | No |
| Location Type | Totally Contained On Operator-Controlled Property |
| Incident Area Type | Aboveground |
| Incident Area Subtype | Typical Aboveground Facility Piping Or Appurtenance |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Valve |
| Valve Type | Auxiliary Or Other Valve |
| Installation Year | 2018 |
| Manufactured Year | Unknown |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Other |
| Leak Type Other | Alt Test Port Needle Valve |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | No |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 54 |
| Est Cost Prop Damage | 50 |
| Est Cost Emergency | 1345 |
| Est Cost Environmental | 0 |
| Est Cost Other | 0 |
| Prpty | 1449 |
| Num Persons Hosp Not Ovnght | 0 |
| Num Injured Treated By Emt | 0 |
| Num Resident Building Affctd | 0 |
| Num Business Building Affctd | 0 |
| Accident Psig | 50 |
| Mop Psig | 559 |
| Mop Cfr Section | Internal Design Pressure �195.406(A)(1) View CFR 49 §192 |
| Maop Established Date | 2021-04-23 00:00:00 |
| Maop Reversal Flow Ind | No |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | Yes |
| Exceed Restriction Ind | No |
| Phmsa Restriction Ind | Not Mandated |
| Pipeline Function | < 20% Smys Regulated Transmission |
| Scada In Place Ind | No |
| Cpm In Place Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | This devices is not designed to be remotely monitored and leak detection would not detect this small amount, so incident did warrant an investigation of the control room. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Equipment Failure |
| Cause Details | Other Equipment Failure |
| Eq Failure Type | Other Equipment Failure |
| Failure Details | Alternate Test Port Fitting Needle Valve Failed |
| Additional Erosion Wear Ind | Yes |
| Eq Additional Other Ind | Yes |
| Eq Additional Other Details | No Able To Identify Additional Factor-Needle Vlv Part Was Sucked Up By Hydrovac. |
| Eqf Defective Fitting Ind | Yes |
| Preparer Name | M*** P***** |
| Preparer Title | Regulatory And Safety Director |
| Preparer Email | M******@s**********.com |
| Preparer Telephone | 4696142257 |
| Prepared Date | 2025-11-13 00:00:00 |
| Local Contact Name | J****** "***** N****** |
| Local Contact Email | N*******@s**********.com |
| Local Contact Telephone | 307-315-3374 |
| Authorizer Name | M*** P***** |
| Authorizer Telephone | 4696142257 |
| Authorizer Title | Regulatory And Safety Director |
| Authorizer Email | M******@s**********.com |
| Narrative | Station operator arrived at 14:30 pm on 10/15/2025 for a station check and discovered that release from a needle valve was in progress. This is a 1/2� needle valve on the alternate test port fitting on the tank manifold inlet surge relief valve. Failure resulted in a 36-gal release of crude. As a permanent containment and repair, 1/2� fitting and ball valve was installed to replace the needle valve. Some of the needle valve was missing. Being a small part, it was not found and probably sucked up when the hydrovac operations were being conducted to remove the contaminated soil. Therefore, it is unknow how the needle valve failed. This was not a piece of equipment that is remotely monitored and the small volume of discharge would not have been detected from the operations center. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA