HL incident on 2025-10-02 — TX

Operator
Shell Pipeline Co., L.p.
Cause
Material Failure Of Pipe Or Weld
Commodity
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$150,000
Incident datetime
2025-10-02 08:00
Report number
Location
TX
Narrative
On the morning of october 2, a mowing crew saw some bubbles coming up from a puddle of water on the row near our pipeline. They called our staff to come out and evaluate the situation. Out of caution, the pipeline was shut down until further investigation could be conducted. Since the release occurred in a swampy area, mobbing equipment and mats to the work site took some additional time but ultimately was discovered that the line had a pin hole leak in the weld. The repair was made with a clamp and the leak stopped. The pipe was tested and then backfilled. The release was attributed to a pin hole in the girth weld from original construction. The reported amount was just over 21 pounds below the reportable quantity, so the accident report is being made for exceeding the $50,000 threshold.
Detailed record list
Report Received Date
2025-11-07 00:00:00
Iyear
2025
Report Number
20250259
Supplemental Number
41562
Report Type
Original Final
Operator Id
Name
Shell Pipeline Co., L.p.
Operator Street Address
150 North Dairy Ashford Road Wck Bldg. A
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77079
Local Datetime
2025-10-02 08:00:00
Time Zone
Central
Daylight Savings Ind
No
Location Latitude
Location Longitude
Commodity Released Type
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype
Other Hvl
Commodity Details
Ethylene
Unintentional Release Bbls
0.1
Intentional Release Bbls
0
Recovered Bbls
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Contractor Working For The Operator
Incident Identified Datetime
2025-10-02 08:00:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2025-10-02 10:25:00
Restart Datetime
2025-10-05 12:04:00
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2025-10-06 15:40:00
On Site Datetime
2025-10-03 08:00:00
Confirmed Discovery Datetime
2025-10-04 09:00:00
Nrc Rpt Datetime
2025-10-06 15:40:00
Nrc Rpt Num
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2025-10-02 10:25:00
Upstream Valve Type Ind
Automatic
Downstream Action Taken
Operational Control
Downstream Oprtnl Cntrl Detail
The Controller Started The Downstream Pump To In Order To Evacuate The Remaining Ethylene.
Num Pub Evacuated
0
Pipe Fac Name
12" Tlds
Segment Name
Tx-La State Line To Lm05
Onshore State Abbreviation
La
Onshore Postal Code
70668
Onshore City Name
Not Within A Municipality
Onshore County Name
Calcasieu Parish
Designated Location
Milepost
Designated Name
W Of Lm05
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
72
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Weld, Including Heat-Affected Zone
Pipe Diameter
12
Pipe Wall Thickness
0.2
Pipe Smys
65000
Pipe Specification
5l
Pipe Seam Type
Erw - High Frequency
Pipe Manufacturer
American
Pipe Coating Type
Extruded Polyehylene
Coating Applied Ind
No
Weld Subtype
Pipe Girth Weld
Different Girth Weld Ind
No
Installation Year
1979
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
0
Est Cost Prop Damage
150000
Est Cost Emergency
0
Est Cost Environmental
0
Est Cost Other
0
Prpty
150000
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
1135
Mop Psig
1440
Mop Cfr Section
Component Design Pressure �195.406(A)(2)
Maop Established Date
1979-01-01 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The small leak being found by a contractor mowing crew on the right-of-way.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Material Failure Of Pipe Or Weld
Cause Details
Design-, Construction-, Installation-, Or Fabrication-Related
Field Exam Ind
Yes
Failure Type
Design-, Construction-, Installation-, Or Fabrication-Related
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Cir Trn Wave Mgn Flx Lkg Ind
Yes
Geometry Deformation Ind
Yes
Emat Ind
Yes
Axial Recent Year
2022
Axial Rcnt Propul Method
Free Swimming
Axial Rcnt Attuned Detect
Metal Loss
Axial Rcnt Atnd Dtct Metal
High Resolution
Axial Previous Year
2019
Axial Prev Propul Method
Free Swimming
Axial Prev Attuned Detect
Metal Loss
Axial Prev Atnd Dtct Metal
High Resolution
Circ Wave Recent Year
2016
Circ Wv Rcnt Propul Method
Free Swimming
Circ Wv Rcnt Resolution
High Resolution
Circ Wv Previous Year
2016
Geometry Recent Year
2022
Geometry Rcnt Propul Method
Free Swimming
Geometry Rcnt Resolution
High Resolution
Geometrt Rcnt Measur Cups
Inside Ili Cups
Geometry Previous Year
2019
Geometry Prev Propul Method
Free Swimming
Geometry Prev Resolution
High Resolution
Geometrt Prev Measur Cups
Inside Ili Cups
Emat Recent Year
2016
Emat Rcnt Propul Method
Free Swimming
Emat Previous Year
2016
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
J***** H*****
Preparer Title
Regulatory Support Coordinator
Preparer Email
J************@s****.com
Preparer Telephone
409-540-2781
Prepared Date
2025-11-07 00:00:00
Authorizer Name
D****** P****
Authorizer Telephone
936-499-0580
Authorizer Title
Integrity And Regulatory Manager
Authorizer Email
D************@s****.com
Narrative
On the morning of october 2, a mowing crew saw some bubbles coming up from a puddle of water on the row near our pipeline. They called our staff to come out and evaluate the situation. Out of caution, the pipeline was shut down until further investigation could be conducted. Since the release occurred in a swampy area, mobbing equipment and mats to the work site took some additional time but ultimately was discovered that the line had a pin hole leak in the weld. The repair was made with a clamp and the leak stopped. The pipe was tested and then backfilled. The release was attributed to a pin hole in the girth weld from original construction. The reported amount was just over 21 pounds below the reportable quantity, so the accident report is being made for exceeding the $50,000 threshold.
Report Received Date 2025-11-07 00:00:00
Iyear 2025
Report Number 20250259
Supplemental Number 41562
Report Type Original Final
Operator Id 31174 PHMSA Enforcement
Name Shell Pipeline Co., L.p.
Operator Street Address 150 North Dairy Ashford Road Wck Bldg. A
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77079
Local Datetime 2025-10-02 08:00:00
Time Zone Central
Daylight Savings Ind No
Location Latitude 30.07775 Google Maps OpenStreetMap
Location Longitude -93.50181 Google Maps OpenStreetMap
Commodity Released Type Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype Other Hvl
Commodity Details Ethylene
Unintentional Release Bbls 0.1
Intentional Release Bbls 0
Recovered Bbls 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Contractor Working For The Operator
Incident Identified Datetime 2025-10-02 08:00:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind Yes
Shutdown Datetime 2025-10-02 10:25:00
Restart Datetime 2025-10-05 12:04:00
Communication State Fed Ind Yes
Party Initiated Communication Operator
Initial Responder Com Datetime 2025-10-06 15:40:00
On Site Datetime 2025-10-03 08:00:00
Confirmed Discovery Datetime 2025-10-04 09:00:00
Nrc Rpt Datetime 2025-10-06 15:40:00
Nrc Rpt Num 1444774 NRC Report How to search
Ignite Ind No
Upstream Action Taken Valve Closure
Upstream Valve Close Datetime 2025-10-02 10:25:00
Upstream Valve Type Ind Automatic
Downstream Action Taken Operational Control
Downstream Oprtnl Cntrl Detail The Controller Started The Downstream Pump To In Order To Evacuate The Remaining Ethylene.
Num Pub Evacuated 0
Pipe Fac Name 12" Tlds
Segment Name Tx-La State Line To Lm05
Onshore State Abbreviation La
Onshore Postal Code 70668
Onshore City Name Not Within A Municipality
Onshore County Name Calcasieu Parish
Designated Location Milepost
Designated Name W Of Lm05
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 72
Crossing No
Pipe Facility Type Interstate
Item Involved Weld, Including Heat-Affected Zone
Pipe Diameter 12
Pipe Wall Thickness 0.2
Pipe Smys 65000
Pipe Specification 5l
Pipe Seam Type Erw - High Frequency
Pipe Manufacturer American
Pipe Coating Type Extruded Polyehylene
Coating Applied Ind No
Weld Subtype Pipe Girth Weld
Different Girth Weld Ind No
Installation Year 1979
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination No
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca No
Commodity Reached Hca No
Est Cost Oper Paid 0
Est Cost Gas Released 0
Est Cost Prop Damage 150000
Est Cost Emergency 0
Est Cost Environmental 0
Est Cost Other 0
Prpty 150000
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 1135
Mop Psig 1440
Mop Cfr Section Component Design Pressure �195.406(A)(2) View CFR 49 §192
Maop Established Date 1979-01-01 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind No
Cpm Conf Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details The small leak being found by a contractor mowing crew on the right-of-way.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Material Failure Of Pipe Or Weld
Cause Details Design-, Construction-, Installation-, Or Fabrication-Related
Field Exam Ind Yes
Failure Type Design-, Construction-, Installation-, Or Fabrication-Related
Collected Data Ind Yes
Axial Magnetic Flx Lkg Ind Yes
Cir Trn Wave Mgn Flx Lkg Ind Yes
Geometry Deformation Ind Yes
Emat Ind Yes
Axial Recent Year 2022
Axial Rcnt Propul Method Free Swimming
Axial Rcnt Attuned Detect Metal Loss
Axial Rcnt Atnd Dtct Metal High Resolution
Axial Previous Year 2019
Axial Prev Propul Method Free Swimming
Axial Prev Attuned Detect Metal Loss
Axial Prev Atnd Dtct Metal High Resolution
Circ Wave Recent Year 2016
Circ Wv Rcnt Propul Method Free Swimming
Circ Wv Rcnt Resolution High Resolution
Circ Wv Previous Year 2016
Geometry Recent Year 2022
Geometry Rcnt Propul Method Free Swimming
Geometry Rcnt Resolution High Resolution
Geometrt Rcnt Measur Cups Inside Ili Cups
Geometry Previous Year 2019
Geometry Prev Propul Method Free Swimming
Geometry Prev Resolution High Resolution
Geometrt Prev Measur Cups Inside Ili Cups
Emat Recent Year 2016
Emat Rcnt Propul Method Free Swimming
Emat Previous Year 2016
Has Hydrtst Conduc Before Ind No
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name J***** H*****
Preparer Title Regulatory Support Coordinator
Preparer Email J************@s****.com
Preparer Telephone 409-540-2781
Prepared Date 2025-11-07 00:00:00
Authorizer Name D****** P****
Authorizer Telephone 936-499-0580
Authorizer Title Integrity And Regulatory Manager
Authorizer Email D************@s****.com
Narrative On the morning of october 2, a mowing crew saw some bubbles coming up from a puddle of water on the row near our pipeline. They called our staff to come out and evaluate the situation. Out of caution, the pipeline was shut down until further investigation could be conducted. Since the release occurred in a swampy area, mobbing equipment and mats to the work site took some additional time but ultimately was discovered that the line had a pin hole leak in the weld. The repair was made with a clamp and the leak stopped. The pipe was tested and then backfilled. The release was attributed to a pin hole in the girth weld from original construction. The reported amount was just over 21 pounds below the reportable quantity, so the accident report is being made for exceeding the $50,000 threshold.

All rights reserved. Copyright © by ClearPHMSA