Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2025-08-26 — TX
Operator
Exxonmobil Pipeline Company Llc
Cause
Incorrect Operation
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$0
Incident datetime
2025-08-26 03:45
Report number
Location
TX
Narrative
A release of gasoline/diesel occurred at zachary product station between the evening of august 25th and morning of august 26th, 2025. The event was first identified when a technician responded to a gas detector alarm around 2:45 am. Upon arrival at 3:45am, the technician observed product coming from a 1/2-inch ball valve located at the 12 o�clock position of the scraper trap. The technician immediately closed the valve. Appropriate notifications were made to agencies and site remediation efforts have concluded. The investigation determined that the 1/2-inch valve was inadvertently left open after completing maintenance activities on august 25th.
Detailed record list
Report Received Date
2025-09-24 00:00:00
Iyear
2025
Report Number
20250229
Supplemental Number
41400
Report Type
Original Final
Operator Id
4906
Name
Exxonmobil Pipeline Company Llc
Operator Street Address
22777 Springwoods Village Parkway E2.2b-Emp
Operator City Name
Spring
Operator State Abbreviation
TX
Operator Postal Code
77389
Local Datetime
2025-08-25 19:47:00
Time Zone
Central
Daylight Savings Ind
No
Location Latitude
30.71153
Location Longitude
-91.28
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Other
Commodity Details
Gasoline And Diesel
Unintentional Release Bbls
2.26
Recovered Bbls
0.9
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations)
Incident Identified Datetime
2025-08-26 03:45:00
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
No
Shutdown Explain
Release Could Safely Be Stopped Without Shutting Down The Pipeline.
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2025-08-26 08:42:00
On Site Datetime
2025-08-26 05:30:00
Confirmed Discovery Datetime
2025-08-26 08:15:00
Nrc Rpt Datetime
2025-08-26 09:03:00
Nrc Rpt Num
1440907
Additional Nrc Report Numbers
1441319
Ignite Ind
No
Notify Qualified Indiv Ind
Yes
Qualified Indiv Notif Datetime
2025-08-26 04:18:00
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Zachary Products Station
Segment Name
La-90 Baton Rouge Refinery - Zachary Product
Onshore State Abbreviation
La
Onshore Postal Code
70748
Onshore City Name
Jackson
Onshore County Name
East Feliciana
Designated Location
Survey Station No.
Designated Name
167+56
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Valve
Valve Type
Auxiliary Or Other Valve
Installation Year
2025
Manufactured Year
Unknown
Material Involved
Material Other Than Carbon Steel
Material Details
Stainless Steel
Release Type
Other
Release Type Details
Half Inch Quarter Turn Ball Valve Left In The Open Position.
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
210
Est Cost Prop Damage
0
Est Cost Emergency
0
Est Cost Environmental
5000
Est Cost Other
0
Prpty
5210
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
21
Mop Psig
1440
Mop Cfr Section
Subpart E Pressure Test �195.406(A)(3)
Maop Established Date
1993-08-21 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Not applicable to this incident.
Employee Drug Test Ind
Yes
Contractor Drug Test Ind
No
Num Employees Tested
1
Num Employees Failed
0
Cause
Incorrect Operation
Cause Details
Valve Left Or Placed In Wrong Position, But Not Resulting In A Tank, Vessel, Or Sump/separator Overflow Or Facility Overpressure
Operation Type
Valve Left Or Placed In Wrong Position, But Not Resulting In A Tank, Vessel, Or Sump/separator Overflow Or Facility Overpressure
Related Inadequate Proc Ind
Yes
Category Type
Routine Maintenance
Operator Qualification Ind
Yes
Qualified Individuals
Yes, They Were Qualified For The Task(S)
Preparer Name
A***** M*****
Preparer Title
Regulatory Compliance Advisor
Preparer Email
A**************@e*********.com
Preparer Telephone
281-755-3984
Prepared Date
2025-09-24 00:00:00
Authorizer Name
L**** B******
Authorizer Telephone
346-474-9151
Authorizer Title
Regulatory Compliance Supervisor
Authorizer Email
L**************@e*********.com
Narrative
A release of gasoline/diesel occurred at zachary product station between the evening of august 25th and morning of august 26th, 2025. The event was first identified when a technician responded to a gas detector alarm around 2:45 am. Upon arrival at 3:45am, the technician observed product coming from a 1/2-inch ball valve located at the 12 o�clock position of the scraper trap. The technician immediately closed the valve. Appropriate notifications were made to agencies and site remediation efforts have concluded. The investigation determined that the 1/2-inch valve was inadvertently left open after completing maintenance activities on august 25th.
| Report Received Date | 2025-09-24 00:00:00 |
|---|---|
| Iyear | 2025 |
| Report Number | 20250229 |
| Supplemental Number | 41400 |
| Report Type | Original Final |
| Operator Id | 4906 PHMSA Enforcement |
| Name | Exxonmobil Pipeline Company Llc |
| Operator Street Address | 22777 Springwoods Village Parkway E2.2b-Emp |
| Operator City Name | Spring |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77389 |
| Local Datetime | 2025-08-25 19:47:00 |
| Time Zone | Central |
| Daylight Savings Ind | No |
| Location Latitude | 30.71153 Google Maps OpenStreetMap |
| Location Longitude | -91.28 Google Maps OpenStreetMap |
| Commodity Released Type | Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions |
| Commodity Subtype | Other |
| Commodity Details | Gasoline And Diesel |
| Unintentional Release Bbls | 2.26 |
| Recovered Bbls | 0.9 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations) |
| Incident Identified Datetime | 2025-08-26 03:45:00 |
| System Part Involved | Onshore Pump/meter Station Equipment And Piping |
| On Off Shore | Onshore |
| Status When Identified | Normal Operation, Includes Pauses Between Batches And During Maintenance |
| Shutdown Due Accident Ind | No |
| Shutdown Explain | Release Could Safely Be Stopped Without Shutting Down The Pipeline. |
| Communication State Fed Ind | Yes |
| Party Initiated Communication | Operator |
| Initial Responder Com Datetime | 2025-08-26 08:42:00 |
| On Site Datetime | 2025-08-26 05:30:00 |
| Confirmed Discovery Datetime | 2025-08-26 08:15:00 |
| Nrc Rpt Datetime | 2025-08-26 09:03:00 |
| Nrc Rpt Num | 1440907 NRC Report How to search |
| Additional Nrc Report Numbers | 1441319 |
| Ignite Ind | No |
| Notify Qualified Indiv Ind | Yes |
| Qualified Indiv Notif Datetime | 2025-08-26 04:18:00 |
| Oil Spill Removal Org Ind | No |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Zachary Products Station |
| Segment Name | La-90 Baton Rouge Refinery - Zachary Product |
| Onshore State Abbreviation | La |
| Onshore Postal Code | 70748 |
| Onshore City Name | Jackson |
| Onshore County Name | East Feliciana |
| Designated Location | Survey Station No. |
| Designated Name | 167+56 |
| Federal | No |
| Location Type | Totally Contained On Operator-Controlled Property |
| Incident Area Type | Aboveground |
| Incident Area Subtype | Typical Aboveground Facility Piping Or Appurtenance |
| Crossing | No |
| Pipe Facility Type | Interstate |
| Item Involved | Valve |
| Valve Type | Auxiliary Or Other Valve |
| Installation Year | 2025 |
| Manufactured Year | Unknown |
| Material Involved | Material Other Than Carbon Steel |
| Material Details | Stainless Steel |
| Release Type | Other |
| Release Type Details | Half Inch Quarter Turn Ball Valve Left In The Open Position. |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | No |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 210 |
| Est Cost Prop Damage | 0 |
| Est Cost Emergency | 0 |
| Est Cost Environmental | 5000 |
| Est Cost Other | 0 |
| Prpty | 5210 |
| Num Persons Hosp Not Ovnght | 0 |
| Num Injured Treated By Emt | 0 |
| Num Resident Building Affctd | 0 |
| Num Business Building Affctd | 0 |
| Accident Psig | 21 |
| Mop Psig | 1440 |
| Mop Cfr Section | Subpart E Pressure Test �195.406(A)(3) View CFR 49 §192 |
| Maop Established Date | 1993-08-21 00:00:00 |
| Maop Reversal Flow Ind | No |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | Yes |
| Scada Conf Ind | No |
| Cpm In Place Ind | Yes |
| Cpm Operating Ind | Yes |
| Cpm Functional Ind | Yes |
| Cpm Detection Ind | No |
| Cpm Conf Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | Not applicable to this incident. |
| Employee Drug Test Ind | Yes |
| Contractor Drug Test Ind | No |
| Num Employees Tested | 1 |
| Num Employees Failed | 0 |
| Cause | Incorrect Operation |
| Cause Details | Valve Left Or Placed In Wrong Position, But Not Resulting In A Tank, Vessel, Or Sump/separator Overflow Or Facility Overpressure |
| Operation Type | Valve Left Or Placed In Wrong Position, But Not Resulting In A Tank, Vessel, Or Sump/separator Overflow Or Facility Overpressure |
| Related Inadequate Proc Ind | Yes |
| Category Type | Routine Maintenance |
| Operator Qualification Ind | Yes |
| Qualified Individuals | Yes, They Were Qualified For The Task(S) |
| Preparer Name | A***** M***** |
| Preparer Title | Regulatory Compliance Advisor |
| Preparer Email | A**************@e*********.com |
| Preparer Telephone | 281-755-3984 |
| Prepared Date | 2025-09-24 00:00:00 |
| Authorizer Name | L**** B****** |
| Authorizer Telephone | 346-474-9151 |
| Authorizer Title | Regulatory Compliance Supervisor |
| Authorizer Email | L**************@e*********.com |
| Narrative | A release of gasoline/diesel occurred at zachary product station between the evening of august 25th and morning of august 26th, 2025. The event was first identified when a technician responded to a gas detector alarm around 2:45 am. Upon arrival at 3:45am, the technician observed product coming from a 1/2-inch ball valve located at the 12 o�clock position of the scraper trap. The technician immediately closed the valve. Appropriate notifications were made to agencies and site remediation efforts have concluded. The investigation determined that the 1/2-inch valve was inadvertently left open after completing maintenance activities on august 25th. |