HL incident on 2025-08-20 — TX

Operator
Energy Transfer Company
Cause
Notification Issue
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$26,000
Incident datetime
2025-08-20 07:09
Report number
Location
TX
Narrative
On 8/20/2025 at approximately 07:09, a landowner reported they struck the 21001.08 - 10inch zephyr to talpa line with a ripper attachment on their bulldozer while cleaning out a creek for a culvert install. The line was shutdown and valves isolated. The line was exposed and a dent with through-wall puncture was found. Approximately 200 barrels of crude oil was released. Osro and contractors cleaned-up the released product and removed impacted soil. The leak was repaired with a plidco clamp. On 8/21/2025 at approximately 02:00 the line was restarted. The cause of the accident was due to excavation damage by a third party. To prevent reoccurrence, a failure to comply letter was sent to the landowner.
Detailed record list
Report Received Date
2025-09-19 00:00:00
Iyear
2025
Report Number
20250227
Supplemental Number
41390
Report Type
Original Final
Operator Id
Name
Energy Transfer Company
Operator Street Address
1300 Main Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2025-08-20 07:09:00
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
200
Recovered Bbls
200
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Third Party That Caused The Accident
Incident Identified Datetime
2025-08-20 07:09:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2025-08-20 07:20:00
Restart Datetime
2025-08-21 02:00:00
Communication State Fed Ind
No
On Site Datetime
2025-08-20 10:30:00
Confirmed Discovery Datetime
2025-08-20 07:30:00
Nrc Rpt Datetime
2025-08-20 08:17:00
Nrc Rpt Num
Additional Nrc Report Numbers
1440577
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2025-08-20 07:20:00
Upstream Valve Type Ind
Remotely Controlled
Downstream Action Taken
Valve Closure
Downstream Vlv Close Datetime
2025-08-20 07:20:00
Downstream Valve Type Ind
Remotely Controlled
Notify Qualified Indiv Ind
Yes
Qualified Indiv Notif Datetime
2025-08-20 08:00:00
Oil Spill Removal Org Ind
Yes
Osro Activated Datetime
2025-08-20 09:50:00
Osro Arrived On Site Dt
8/20/2025 13:00
Num Pub Evacuated
0
Pipe Fac Name
Amdel Pipeline
Segment Name
21001.08 - 10 Inch Zephyr To Talpa
Onshore State Abbreviation
Tx
Onshore Postal Code
76878
Onshore City Name
Not Within A Municipality
Onshore County Name
Coleman
Designated Location
Survey Station No.
Designated Name
108113.7
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
36
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Puddle Weld Ind
No
Pipe Diameter
10
Pipe Wall Thickness
0.307
Pipe Smys
35000
Pipe Specification
Gr. B
Pipe Seam Type
Seamless
Pipe Manufacturer
Unknown
Pipe Coating Type
Cold Applied Tape
Coating Applied Ind
Yes
Installation Year
1928
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Mechanical Puncture
Puncture Axial
2
Puncture Circum
2
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
3250
Est Cost Prop Damage
26000
Est Cost Emergency
183904
Est Cost Environmental
300000
Est Cost Other
0
Prpty
513154
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
650
Mop Psig
1147
Mop Cfr Section
Subpart E Pressure Test �195.406(A)(3)
Maop Established Date
2024-06-25 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
258720
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
Yes
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
Yes
Cpm Conf Ind
Yes
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
A review of the accident determined that there were no control room actions that contributed to the event.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
No
State Law Exempt Ind
No
Notify Cga Dirt
No
Private Row Ind
Yes
Private Subtype
Private Landowner
Joint Trench Ind
No
Cross Bore Ind
No
Depth Of Grade
18� � 36�
Excavator Type
Farmer
Excavator Equipment
Bulldozer
Work Performed
Storm Drain/culvert
One Call Notified Ind
No
Locator Type
Unknown/other
Visible Marks
No
Service Interruption
Yes
Service Interruption Hours
19
Root Cause Category
Notification Issue
Root Cause Type
No Notification Made To The One-Call Center/811
Preparer Name
T*** N*******
Preparer Title
Director - Dot Compliance
Preparer Email
T************@e*************.com
Preparer Telephone
713-989-7126
Prepared Date
2025-09-19 00:00:00
Authorizer Name
T*** N*******
Authorizer Telephone
713-989-7126
Authorizer Title
Director - Dot Compliance
Authorizer Email
T************@e*************.com
Narrative
On 8/20/2025 at approximately 07:09, a landowner reported they struck the 21001.08 - 10inch zephyr to talpa line with a ripper attachment on their bulldozer while cleaning out a creek for a culvert install. The line was shutdown and valves isolated. The line was exposed and a dent with through-wall puncture was found. Approximately 200 barrels of crude oil was released. Osro and contractors cleaned-up the released product and removed impacted soil. The leak was repaired with a plidco clamp. On 8/21/2025 at approximately 02:00 the line was restarted. The cause of the accident was due to excavation damage by a third party. To prevent reoccurrence, a failure to comply letter was sent to the landowner.
Report Received Date 2025-09-19 00:00:00
Iyear 2025
Report Number 20250227
Supplemental Number 41390
Report Type Original Final
Operator Id 32099 PHMSA Enforcement
Name Energy Transfer Company
Operator Street Address 1300 Main Street
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77002
Local Datetime 2025-08-20 07:09:00
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 31.692377 Google Maps OpenStreetMap
Location Longitude -99.294433 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 200
Recovered Bbls 200
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Notification From Third Party That Caused The Accident
Incident Identified Datetime 2025-08-20 07:09:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind Yes
Shutdown Datetime 2025-08-20 07:20:00
Restart Datetime 2025-08-21 02:00:00
Communication State Fed Ind No
On Site Datetime 2025-08-20 10:30:00
Confirmed Discovery Datetime 2025-08-20 07:30:00
Nrc Rpt Datetime 2025-08-20 08:17:00
Nrc Rpt Num 1440378 NRC Report How to search
Additional Nrc Report Numbers 1440577
Ignite Ind No
Upstream Action Taken Valve Closure
Upstream Valve Close Datetime 2025-08-20 07:20:00
Upstream Valve Type Ind Remotely Controlled
Downstream Action Taken Valve Closure
Downstream Vlv Close Datetime 2025-08-20 07:20:00
Downstream Valve Type Ind Remotely Controlled
Notify Qualified Indiv Ind Yes
Qualified Indiv Notif Datetime 2025-08-20 08:00:00
Oil Spill Removal Org Ind Yes
Osro Activated Datetime 2025-08-20 09:50:00
Osro Arrived On Site Dt 8/20/2025 13:00
Num Pub Evacuated 0
Pipe Fac Name Amdel Pipeline
Segment Name 21001.08 - 10 Inch Zephyr To Talpa
Onshore State Abbreviation Tx
Onshore Postal Code 76878
Onshore City Name Not Within A Municipality
Onshore County Name Coleman
Designated Location Survey Station No.
Designated Name 108113.7
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 36
Crossing No
Pipe Facility Type Interstate
Item Involved Pipe
Pipe Type Pipe Body
Puddle Weld Ind No
Pipe Diameter 10
Pipe Wall Thickness 0.307
Pipe Smys 35000
Pipe Specification Gr. B
Pipe Seam Type Seamless
Pipe Manufacturer Unknown
Pipe Coating Type Cold Applied Tape
Coating Applied Ind Yes
Installation Year 1928
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Mechanical Puncture
Puncture Axial 2
Puncture Circum 2
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind Yes
Soil Remed Ind Yes
Water Contam Ind No
Could Be Hca No
Commodity Reached Hca No
Est Cost Oper Paid 0
Est Cost Gas Released 3250
Est Cost Prop Damage 26000
Est Cost Emergency 183904
Est Cost Environmental 300000
Est Cost Other 0
Prpty 513154
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 650
Mop Psig 1147
Mop Cfr Section Subpart E Pressure Test �195.406(A)(3) View CFR 49 §192
Maop Established Date 2024-06-25 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 258720
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind Yes
Scada Conf Ind Yes
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind Yes
Cpm Conf Ind Yes
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details A review of the accident determined that there were no control room actions that contributed to the event.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Excavation Damage
Cause Details Excavation Damage By Third Party
Ex Party Type Excavation Damage By Third Party
Prior Notification Ind No
State Law Exempt Ind No
Notify Cga Dirt No
Private Row Ind Yes
Private Subtype Private Landowner
Joint Trench Ind No
Cross Bore Ind No
Depth Of Grade 18� � 36�
Excavator Type Farmer
Excavator Equipment Bulldozer
Work Performed Storm Drain/culvert
One Call Notified Ind No
Locator Type Unknown/other
Visible Marks No
Service Interruption Yes
Service Interruption Hours 19
Root Cause Category Notification Issue
Root Cause Type No Notification Made To The One-Call Center/811
Preparer Name T*** N*******
Preparer Title Director - Dot Compliance
Preparer Email T************@e*************.com
Preparer Telephone 713-989-7126
Prepared Date 2025-09-19 00:00:00
Authorizer Name T*** N*******
Authorizer Telephone 713-989-7126
Authorizer Title Director - Dot Compliance
Authorizer Email T************@e*************.com
Narrative On 8/20/2025 at approximately 07:09, a landowner reported they struck the 21001.08 - 10inch zephyr to talpa line with a ripper attachment on their bulldozer while cleaning out a creek for a culvert install. The line was shutdown and valves isolated. The line was exposed and a dent with through-wall puncture was found. Approximately 200 barrels of crude oil was released. Osro and contractors cleaned-up the released product and removed impacted soil. The leak was repaired with a plidco clamp. On 8/21/2025 at approximately 02:00 the line was restarted. The cause of the accident was due to excavation damage by a third party. To prevent reoccurrence, a failure to comply letter was sent to the landowner.

All rights reserved. Copyright © by ClearPHMSA