HL incident on 2025-08-04 — CA

Operator
Dcor, Llc
Cause
Natural Force Damage
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$0
Incident datetime
2025-08-04 18:30
Report number
Location
CA
Narrative
A tree branch along spinnaker drive, outside of the harbor station property boundary, broke off and hit the dcor pipeline asset within the station. The branch broke off a 1/2" fitting (pressure sensing line) on the 6" mosf tie-in line near to where it enter the 22" vps pipeline (mop of 285 psig). The line was shut down at the time but was under approximately 227 psig static head. The pressure alarm low (pal) switch that was sheared off by the tree branch was set at 185 psig, triggering a scada and audible alarm at the vps controller who immediately shut all remote-controlled valves through the scada and performed an emergency row inspection to identify if there was a release. Upon arriving at harbor station, the operator supported police and fire, and communicated the accident to dcor management. Emergency crews (police and fire) were already on site, having been notified by a community member driving past the location. Dcor personnel notified cal oes (#25 3868) and nrc (# 1438900). Both reports were made within 1hour of identifying the accident. Dcor called out their response contractor. By the following morning, contractor had removed 3 roll-off boxes with soiled material, had backfilled with clean gravel, and cleaned spinnaker drive allowing the roadway to be reopen. The pal switch was reinstalled by the 7th. And the line restarted. No other damage was noted. Dcor personnel notified nrc prior to the 48-hour update requirement (nrc #1439048).
Detailed record list
Report Received Date
2025-09-10 00:00:00
Iyear
2025
Report Number
20250212
Supplemental Number
41542
Report Type
Supplemental
Operator Id
Name
Dcor, Llc
Operator Street Address
1000 Town Center Drive Suite 600
Operator City Name
Oxnard
Operator State Abbreviation
CA
Operator Postal Code
93036
Local Datetime
2025-08-04 18:00:00
Time Zone
Pacific
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
5.61
Recovered Bbls
5.61
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations)
Incident Identified Datetime
2025-08-04 18:30:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Idle
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2025-08-04 19:00:00
On Site Datetime
2025-08-04 19:00:00
Confirmed Discovery Datetime
2025-08-04 19:00:00
Nrc Rpt Datetime
2025-08-04 19:40:00
Nrc Rpt Num
Additional Nrc Report Numbers
1439048
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2025-08-04 19:00:00
Upstream Valve Type Ind
Remotely Controlled
Downstream Action Taken
Valve Closure
Downstream Vlv Close Datetime
2025-08-04 19:00:00
Downstream Valve Type Ind
Manual
Notify Qualified Indiv Ind
Yes
Qualified Indiv Notif Datetime
2025-08-04 19:00:00
Oil Spill Removal Org Ind
Yes
Osro Activated Datetime
2025-08-04 19:00:00
Osro Arrived On Site Dt
8/4/2025 20:00
Num Pub Evacuated
0
Pipe Fac Name
Ventura Pipeline System (Vps)
Segment Name
Vps 22" M-143
Onshore State Abbreviation
Ca
Onshore Postal Code
93001
Onshore City Name
Ventura
Onshore County Name
Ventura County
Designated Location
Milepost
Designated Name
14.03
Federal
No
Location Type
Originated On Operator-Controlled Property, But Then Flowed Or Migrated Off The Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Tubing
Tubing Material
Carbon Steel
Tubing Type
Rigid
Installation Year
Unknown
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Other
Release Type Details
Accident Was Caused By A Tree Branch Falling Onto A 1/2" Sensing Line.
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Usa Ecological Ind
Yes
Usa Ecological Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
500
Est Cost Prop Damage
0
Est Cost Emergency
20000
Est Cost Environmental
30000
Est Cost Other
0
Prpty
50500
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
227
Mop Psig
285
Mop Cfr Section
Component Design Pressure �195.406(A)(2)
Maop Established Date
1990-01-01 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
5926
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
< 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
Yes
Cpm In Place Ind
Yes
Cpm Operating Ind
No
Cpm Functional Ind
Yes
Cpm Detection Ind
Yes
Cpm Conf Ind
Yes
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest Schedule Ind
Yes
Invest No Control Room Ind
Yes
Invest No Controller Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Natural Force Damage
Cause Details
Trees/vegetation Roots
Natural Force Type
Trees/vegetation Roots
Nf Extreme Weather Ind
No
Outside Force Type
Other Outside Force Damage
Osf Other Details
Accident Was Caused By A Tree Branch Falling Onto A 1/2" Sensing Line.
Nf Vegitation Root Ind
Yes
Preparer Name
A***** K*******
Preparer Title
Director Of Pipelines
Preparer Email
A********@d******.com
Preparer Telephone
4126574788
Prepared Date
2025-11-03 00:00:00
Local Contact Name
A***** K*******
Local Contact Email
A********@d******.com
Local Contact Telephone
4126574788
Authorizer Name
A***** K*******
Authorizer Telephone
4126574788
Authorizer Title
Director Of Pipelines
Authorizer Email
A********@d******.com
Narrative
A tree branch along spinnaker drive, outside of the harbor station property boundary, broke off and hit the dcor pipeline asset within the station. The branch broke off a 1/2" fitting (pressure sensing line) on the 6" mosf tie-in line near to where it enter the 22" vps pipeline (mop of 285 psig). The line was shut down at the time but was under approximately 227 psig static head. The pressure alarm low (pal) switch that was sheared off by the tree branch was set at 185 psig, triggering a scada and audible alarm at the vps controller who immediately shut all remote-controlled valves through the scada and performed an emergency row inspection to identify if there was a release. Upon arriving at harbor station, the operator supported police and fire, and communicated the accident to dcor management. Emergency crews (police and fire) were already on site, having been notified by a community member driving past the location. Dcor personnel notified cal oes (#25 3868) and nrc (# 1438900). Both reports were made within 1hour of identifying the accident. Dcor called out their response contractor. By the following morning, contractor had removed 3 roll-off boxes with soiled material, had backfilled with clean gravel, and cleaned spinnaker drive allowing the roadway to be reopen. The pal switch was reinstalled by the 7th. And the line restarted. No other damage was noted. Dcor personnel notified nrc prior to the 48-hour update requirement (nrc #1439048).
Report Received Date 2025-09-10 00:00:00
Iyear 2025
Report Number 20250212
Supplemental Number 41542
Report Type Supplemental
Operator Id 32083 PHMSA Enforcement
Name Dcor, Llc
Operator Street Address 1000 Town Center Drive Suite 600
Operator City Name Oxnard
Operator State Abbreviation CA
Operator Postal Code 93036
Local Datetime 2025-08-04 18:00:00
Time Zone Pacific
Daylight Savings Ind Yes
Location Latitude 34.243333 Google Maps OpenStreetMap
Location Longitude -119.259036 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 5.61
Recovered Bbls 5.61
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations)
Incident Identified Datetime 2025-08-04 18:30:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Status When Identified Idle
Communication State Fed Ind Yes
Party Initiated Communication Operator
Initial Responder Com Datetime 2025-08-04 19:00:00
On Site Datetime 2025-08-04 19:00:00
Confirmed Discovery Datetime 2025-08-04 19:00:00
Nrc Rpt Datetime 2025-08-04 19:40:00
Nrc Rpt Num 1438900 NRC Report How to search
Additional Nrc Report Numbers 1439048
Ignite Ind No
Upstream Action Taken Valve Closure
Upstream Valve Close Datetime 2025-08-04 19:00:00
Upstream Valve Type Ind Remotely Controlled
Downstream Action Taken Valve Closure
Downstream Vlv Close Datetime 2025-08-04 19:00:00
Downstream Valve Type Ind Manual
Notify Qualified Indiv Ind Yes
Qualified Indiv Notif Datetime 2025-08-04 19:00:00
Oil Spill Removal Org Ind Yes
Osro Activated Datetime 2025-08-04 19:00:00
Osro Arrived On Site Dt 8/4/2025 20:00
Num Pub Evacuated 0
Pipe Fac Name Ventura Pipeline System (Vps)
Segment Name Vps 22" M-143
Onshore State Abbreviation Ca
Onshore Postal Code 93001
Onshore City Name Ventura
Onshore County Name Ventura County
Designated Location Milepost
Designated Name 14.03
Federal No
Location Type Originated On Operator-Controlled Property, But Then Flowed Or Migrated Off The Property
Incident Area Type Aboveground
Incident Area Subtype Typical Aboveground Facility Piping Or Appurtenance
Crossing No
Pipe Facility Type Intrastate
Item Involved Tubing
Tubing Material Carbon Steel
Tubing Type Rigid
Installation Year Unknown
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Other
Release Type Details Accident Was Caused By A Tree Branch Falling Onto A 1/2" Sensing Line.
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca Yes
High Pop Ind Yes
High Pop Yes No Yes
Usa Ecological Ind Yes
Usa Ecological Yes No Yes
Est Cost Oper Paid 0
Est Cost Gas Released 500
Est Cost Prop Damage 0
Est Cost Emergency 20000
Est Cost Environmental 30000
Est Cost Other 0
Prpty 50500
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 227
Mop Psig 285
Mop Cfr Section Component Design Pressure �195.406(A)(2) View CFR 49 §192
Maop Established Date 1990-01-01 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 5926
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function < 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind Yes
Scada Conf Ind Yes
Cpm In Place Ind Yes
Cpm Operating Ind No
Cpm Functional Ind Yes
Cpm Detection Ind Yes
Cpm Conf Ind Yes
Investigation Status Yes, specify investigation result(s): (select all that apply)
Invest Schedule Ind Yes
Invest No Control Room Ind Yes
Invest No Controller Ind Yes
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Natural Force Damage
Cause Details Trees/vegetation Roots
Natural Force Type Trees/vegetation Roots
Nf Extreme Weather Ind No
Outside Force Type Other Outside Force Damage
Osf Other Details Accident Was Caused By A Tree Branch Falling Onto A 1/2" Sensing Line.
Nf Vegitation Root Ind Yes
Preparer Name A***** K*******
Preparer Title Director Of Pipelines
Preparer Email A********@d******.com
Preparer Telephone 4126574788
Prepared Date 2025-11-03 00:00:00
Local Contact Name A***** K*******
Local Contact Email A********@d******.com
Local Contact Telephone 4126574788
Authorizer Name A***** K*******
Authorizer Telephone 4126574788
Authorizer Title Director Of Pipelines
Authorizer Email A********@d******.com
Narrative A tree branch along spinnaker drive, outside of the harbor station property boundary, broke off and hit the dcor pipeline asset within the station. The branch broke off a 1/2" fitting (pressure sensing line) on the 6" mosf tie-in line near to where it enter the 22" vps pipeline (mop of 285 psig). The line was shut down at the time but was under approximately 227 psig static head. The pressure alarm low (pal) switch that was sheared off by the tree branch was set at 185 psig, triggering a scada and audible alarm at the vps controller who immediately shut all remote-controlled valves through the scada and performed an emergency row inspection to identify if there was a release. Upon arriving at harbor station, the operator supported police and fire, and communicated the accident to dcor management. Emergency crews (police and fire) were already on site, having been notified by a community member driving past the location. Dcor personnel notified cal oes (#25 3868) and nrc (# 1438900). Both reports were made within 1hour of identifying the accident. Dcor called out their response contractor. By the following morning, contractor had removed 3 roll-off boxes with soiled material, had backfilled with clean gravel, and cleaned spinnaker drive allowing the roadway to be reopen. The pal switch was reinstalled by the 7th. And the line restarted. No other damage was noted. Dcor personnel notified nrc prior to the 48-hour update requirement (nrc #1439048).

All rights reserved. Copyright © by ClearPHMSA