HL incident on 2025-08-02 — TX

Operator
Nustar Pipeline Operating Partnership L.p.
Cause
Material Failure Of Pipe Or Weld
Commodity
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$64,000
Incident datetime
2025-08-02 12:14
Report number
Location
TX
Narrative
On saturday august 2, 2025, a hunting club member called the sunoco control center reporting some dead vegetation near our pipeline marker near farmerville, la on the sterlington 6-inch lateral in union parish louisiana. Sunoco local operations then verified an ammonia odor in the area of dead vegetation and notified management, and the pipeline was shut down. Valve 43-14 was closed, and the line was allowed to drain into a delivery site at the end of the lateral. Sunoco maintenance arrived on site and uncovered the pipe to discover what appears to be an erw seam failure leaking vapor only. A clamp was put on to stop the leak and a double stopple was performed to cut out the leak point and repair the line. The cut-out portion of the pipe has been sent for metallurgical analysis to determine the cause of the leak. **update** metallurgical analysis: the leak originated from a defect in the weld seam on the inner wall. The primary failure mechanism was a manufacturing linear defect in the weld.
Detailed record list
Report Received Date
2025-08-28 00:00:00
Iyear
2025
Report Number
20250202
Supplemental Number
41585
Report Type
Supplemental Final
Operator Id
Name
Nustar Pipeline Operating Partnership L.p.
Operator Street Address
8111 Westchester Drive
Operator City Name
Dallas
Operator State Abbreviation
TX
Operator Postal Code
75225
Local Datetime
2025-08-02 10:44:00
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype
Anhydrous Ammonia
Unintentional Release Bbls
2.48
Intentional Release Bbls
0
Recovered Bbls
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Public
Incident Identified Datetime
2025-08-02 12:14:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2025-08-02 12:14:00
Restart Datetime
2025-08-06 17:00:00
Communication State Fed Ind
No
On Site Datetime
2025-08-02 12:14:00
Confirmed Discovery Datetime
2025-08-02 12:14:00
Nrc Rpt Datetime
2025-08-02 13:38:00
Nrc Rpt Num
Additional Nrc Report Numbers
1438856
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2025-08-02 12:14:00
Upstream Valve Type Ind
Manual
Downstream Action Taken
Operational Control
Downstream Oprtnl Cntrl Detail
The Line Was Allowed To Bleed Off To Downstream Customer Site.
Num Pub Evacuated
0
Pipe Fac Name
Ammonia Mainline
Segment Name
Sterlington 6-Inch Lateral
Onshore State Abbreviation
La
Onshore Postal Code
71241
Onshore City Name
Farmerville
Onshore County Name
Union
Designated Location
Milepost
Designated Name
14.3
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
54
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Seam
Pipe Diameter
6.625
Pipe Wall Thickness
0.188
Pipe Smys
42000
Pipe Specification
Api 5lx-42
Pipe Seam Type
Erw - High Frequency
Pipe Manufacturer
Unknown
Pipe Coating Type
Cold Applied Tape
Coating Applied Ind
No
Installation Year
1981
Manufactured Year
1981
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Leak Type Other
Sent Metallurgical Analysis
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
75
Est Cost Prop Damage
64000
Est Cost Emergency
0
Est Cost Environmental
0
Est Cost Other
0
Prpty
64075
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
650
Mop Psig
1340
Mop Cfr Section
Subpart E Pressure Test �195.406(A)(3)
Maop Established Date
1981-08-17 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Internal Inspection Ind
Yes
Operation Complications Ind
Yes
Incompat Commod Ind
Yes
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The leak from the pipeline was small enough that it rendered the leak un-detectable by the control center (scada/crm)
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Material Failure Of Pipe Or Weld
Cause Details
Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Metallurgical Ind
Yes
Failure Type
Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Other Factor
Yes
Other Factor Details
The Primary Failure Mechanism Was A Manufacturing Linear Defect In The Weld.
Other Type
Unknown
Unknown Subtype
Still Under Investigation, Cause Of Accident To Be Determined* (*supplemental Report Required)
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
D** T******
Preparer Title
Sr Manager - Health And Safety
Preparer Email
D**********@s*****.com
Preparer Telephone
3167217056
Prepared Date
2025-11-13 00:00:00
Local Contact Name
D** T******
Local Contact Email
D**********@s*****.com
Local Contact Telephone
3167217056
Authorizer Name
D** T******
Authorizer Telephone
3167217056
Authorizer Title
Sr Manager - Health And Safety
Authorizer Email
D**********@s*****.com
Narrative
On saturday august 2, 2025, a hunting club member called the sunoco control center reporting some dead vegetation near our pipeline marker near farmerville, la on the sterlington 6-inch lateral in union parish louisiana. Sunoco local operations then verified an ammonia odor in the area of dead vegetation and notified management, and the pipeline was shut down. Valve 43-14 was closed, and the line was allowed to drain into a delivery site at the end of the lateral. Sunoco maintenance arrived on site and uncovered the pipe to discover what appears to be an erw seam failure leaking vapor only. A clamp was put on to stop the leak and a double stopple was performed to cut out the leak point and repair the line. The cut-out portion of the pipe has been sent for metallurgical analysis to determine the cause of the leak. **update** metallurgical analysis: the leak originated from a defect in the weld seam on the inner wall. The primary failure mechanism was a manufacturing linear defect in the weld.
Report Received Date 2025-08-28 00:00:00
Iyear 2025
Report Number 20250202
Supplemental Number 41585
Report Type Supplemental Final
Operator Id 10012 PHMSA Enforcement
Name Nustar Pipeline Operating Partnership L.p.
Operator Street Address 8111 Westchester Drive
Operator City Name Dallas
Operator State Abbreviation TX
Operator Postal Code 75225
Local Datetime 2025-08-02 10:44:00
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 32.77793 Google Maps OpenStreetMap
Location Longitude -92.28436 Google Maps OpenStreetMap
Commodity Released Type Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype Anhydrous Ammonia
Unintentional Release Bbls 2.48
Intentional Release Bbls 0
Recovered Bbls 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Notification From Public
Incident Identified Datetime 2025-08-02 12:14:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind Yes
Shutdown Datetime 2025-08-02 12:14:00
Restart Datetime 2025-08-06 17:00:00
Communication State Fed Ind No
On Site Datetime 2025-08-02 12:14:00
Confirmed Discovery Datetime 2025-08-02 12:14:00
Nrc Rpt Datetime 2025-08-02 13:38:00
Nrc Rpt Num 1438668 NRC Report How to search
Additional Nrc Report Numbers 1438856
Ignite Ind No
Upstream Action Taken Valve Closure
Upstream Valve Close Datetime 2025-08-02 12:14:00
Upstream Valve Type Ind Manual
Downstream Action Taken Operational Control
Downstream Oprtnl Cntrl Detail The Line Was Allowed To Bleed Off To Downstream Customer Site.
Num Pub Evacuated 0
Pipe Fac Name Ammonia Mainline
Segment Name Sterlington 6-Inch Lateral
Onshore State Abbreviation La
Onshore Postal Code 71241
Onshore City Name Farmerville
Onshore County Name Union
Designated Location Milepost
Designated Name 14.3
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 54
Crossing No
Pipe Facility Type Interstate
Item Involved Pipe
Pipe Type Pipe Seam
Pipe Diameter 6.625
Pipe Wall Thickness 0.188
Pipe Smys 42000
Pipe Specification Api 5lx-42
Pipe Seam Type Erw - High Frequency
Pipe Manufacturer Unknown
Pipe Coating Type Cold Applied Tape
Coating Applied Ind No
Installation Year 1981
Manufactured Year 1981
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Leak Type Other Sent Metallurgical Analysis
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca No
Est Cost Oper Paid 0
Est Cost Gas Released 75
Est Cost Prop Damage 64000
Est Cost Emergency 0
Est Cost Environmental 0
Est Cost Other 0
Prpty 64075
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 650
Mop Psig 1340
Mop Cfr Section Subpart E Pressure Test �195.406(A)(3) View CFR 49 §192
Maop Established Date 1981-08-17 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Internal Inspection Ind Yes
Operation Complications Ind Yes
Incompat Commod Ind Yes
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind No
Cpm Conf Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details The leak from the pipeline was small enough that it rendered the leak un-detectable by the control center (scada/crm)
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Material Failure Of Pipe Or Weld
Cause Details Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Metallurgical Ind Yes
Failure Type Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Other Factor Yes
Other Factor Details The Primary Failure Mechanism Was A Manufacturing Linear Defect In The Weld.
Other Type Unknown
Unknown Subtype Still Under Investigation, Cause Of Accident To Be Determined* (*supplemental Report Required)
Collected Data Ind No
Has Hydrtst Conduc Before Ind No
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name D** T******
Preparer Title Sr Manager - Health And Safety
Preparer Email D**********@s*****.com
Preparer Telephone 3167217056
Prepared Date 2025-11-13 00:00:00
Local Contact Name D** T******
Local Contact Email D**********@s*****.com
Local Contact Telephone 3167217056
Authorizer Name D** T******
Authorizer Telephone 3167217056
Authorizer Title Sr Manager - Health And Safety
Authorizer Email D**********@s*****.com
Narrative On saturday august 2, 2025, a hunting club member called the sunoco control center reporting some dead vegetation near our pipeline marker near farmerville, la on the sterlington 6-inch lateral in union parish louisiana. Sunoco local operations then verified an ammonia odor in the area of dead vegetation and notified management, and the pipeline was shut down. Valve 43-14 was closed, and the line was allowed to drain into a delivery site at the end of the lateral. Sunoco maintenance arrived on site and uncovered the pipe to discover what appears to be an erw seam failure leaking vapor only. A clamp was put on to stop the leak and a double stopple was performed to cut out the leak point and repair the line. The cut-out portion of the pipe has been sent for metallurgical analysis to determine the cause of the leak. **update** metallurgical analysis: the leak originated from a defect in the weld seam on the inner wall. The primary failure mechanism was a manufacturing linear defect in the weld.