Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2025-08-14 — OK
Operator
Enlink Permian, Llc
Cause
Equipment Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$20
Incident datetime
2025-08-14 00:00 UTC
Report number
Location
OK
Narrative
At 4:10 pcc received a call from a third party contractor about a potential leak at raptor station. Pcc began to trend data and noticed a drop in pressure then notified the local operator. Operator asked pcc to shut in the upstream and downstream valves and to shut down the station. Operator arrived on site at 6:30 and began to investigate the release. While investigating the operator discovered a broken threaded nipple fitting off the transmitter. Once pump was isolated and blocked in the operator removed the broken nipple and installed a new nipple. The transmitter was reinstalled on the new nipple and the station placed back into normal operations at 7:00. It is believed that the release was the result of vibration due to misalignment of the pump. To prevent recurrence, operations is in the process of relocating transmitters from the pipe to a nearby setting. A supplemental will be submitted once final invoices have been submitted.
Detailed record list
Report Received Date
2025-08-14 00:00:00
Iyear
2025
Report Number
20250187
Supplemental Number
41254
Report Type
Original
Operator Id
32634
Name
Enlink Permian, Llc
Operator Street Address
100 West 5th St.
Operator City Name
Tulsa
Operator State Abbreviation
OK
Operator Postal Code
74103
Time Zone
Mountain
Daylight Savings Ind
Yes
Location Latitude
32.2985317
Location Longitude
-103.6774169
Commodity Released Type
Crude Oil
Unintentional Release Bbls
3
Recovered Bbls
0.5
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Contractor Working For The Operator
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Communication State Fed Ind
No
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Upstream Action Taken
Operational Control
Upstream Oprtnl Cntrl Detail
Gas Control Shut In Remotely
Downstream Action Taken
Operational Control
Downstream Oprtnl Cntrl Detail
Gas Control Shut In Remotely
Notify Qualified Indiv Ind
Yes
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Raptor Cdp
Segment Name
Pressure Transmitter On Station Pipe
Onshore State Abbreviation
Nm
Onshore Postal Code
88252
Onshore City Name
Jal
Onshore County Name
Lea
Designated Location
Survey Station No.
Designated Name
Raptor Cdp
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Other
Item Involved Details
Pressure Transmitter Threaded Nipple
Installation Year
2024
Manufactured Year
2024
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Other
Leak Type Other
Leaking Threaded Nipple
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
204
Est Cost Prop Damage
20
Est Cost Emergency
1000
Est Cost Environmental
45000
Est Cost Other
0
Prpty
46224
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
60
Mop Psig
1400
Mop Cfr Section
Component Design Pressure �195.406(A)(2)
Maop Established Date
2019-05-28 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Internal Inspection Ind
No
Other Inspection Ind
Yes
Internal Inspection Details
Threaded Nipple On Station Piping Not On Pipeline Row
Operation Complications Ind
Yes
Other Complications Ind
Yes
Inspect Comp Details
Not Designed For Tool Run
Pipeline Function
> 20% Smys Regulated Gathering
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
Yes
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
No controller actions took place prior to the release
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Threaded Connection/coupling Failure
Eq Failure Type
Threaded Connection/coupling Failure
Other Stripped Ind
Pipe Nipple
Additional Vibration Ind
Yes
Preparer Name
G*** C*********
Preparer Title
Regulatory Compliance Specialist Ii
Preparer Email
G**************@o****.com
Preparer Telephone
9183818066
Prepared Date
2025-08-14 00:00:00
Authorizer Name
G*** C*********
Authorizer Telephone
5807410185
Authorizer Title
Regulatory Compliance Manager
Authorizer Email
R*********@o****.com
Narrative
At 4:10 pcc received a call from a third party contractor about a potential leak at raptor station. Pcc began to trend data and noticed a drop in pressure then notified the local operator. Operator asked pcc to shut in the upstream and downstream valves and to shut down the station. Operator arrived on site at 6:30 and began to investigate the release. While investigating the operator discovered a broken threaded nipple fitting off the transmitter. Once pump was isolated and blocked in the operator removed the broken nipple and installed a new nipple. The transmitter was reinstalled on the new nipple and the station placed back into normal operations at 7:00. It is believed that the release was the result of vibration due to misalignment of the pump. To prevent recurrence, operations is in the process of relocating transmitters from the pipe to a nearby setting. A supplemental will be submitted once final invoices have been submitted.
Report Received Date | 2025-08-14 00:00:00 |
---|---|
Iyear | 2025 |
Report Number | 20250187 |
Supplemental Number | 41254 |
Report Type | Original |
Operator Id | 32634 PHMSA Enforcement |
Name | Enlink Permian, Llc |
Operator Street Address | 100 West 5th St. |
Operator City Name | Tulsa |
Operator State Abbreviation | OK |
Operator Postal Code | 74103 |
Time Zone | Mountain |
Daylight Savings Ind | Yes |
Location Latitude | 32.2985317 Google Maps OpenStreetMap |
Location Longitude | -103.6774169 Google Maps OpenStreetMap |
Commodity Released Type | Crude Oil |
Unintentional Release Bbls | 3 |
Recovered Bbls | 0.5 |
Fatality Ind | No |
Fatal | 0 |
Injury Ind | No |
Injure | 0 |
Accident Identifier | Local Operating Personnel, Including Contractors |
Operator Type | Contractor Working For The Operator |
System Part Involved | Onshore Pipeline, Including Valve Sites |
On Off Shore | Onshore |
Status When Identified | Normal Operation, Includes Pauses Between Batches And During Maintenance |
Shutdown Due Accident Ind | Yes |
Communication State Fed Ind | No |
Nrc Rpt Num | Nrc Notification Not Required NRC Report How to search |
Ignite Ind | No |
Upstream Action Taken | Operational Control |
Upstream Oprtnl Cntrl Detail | Gas Control Shut In Remotely |
Downstream Action Taken | Operational Control |
Downstream Oprtnl Cntrl Detail | Gas Control Shut In Remotely |
Notify Qualified Indiv Ind | Yes |
Oil Spill Removal Org Ind | No |
Num Pub Evacuated | 0 |
Pipe Fac Name | Raptor Cdp |
Segment Name | Pressure Transmitter On Station Pipe |
Onshore State Abbreviation | Nm |
Onshore Postal Code | 88252 |
Onshore City Name | Jal |
Onshore County Name | Lea |
Designated Location | Survey Station No. |
Designated Name | Raptor Cdp |
Federal | No |
Location Type | Totally Contained On Operator-Controlled Property |
Incident Area Type | Aboveground |
Incident Area Subtype | Typical Aboveground Facility Piping Or Appurtenance |
Crossing | No |
Pipe Facility Type | Interstate |
Item Involved | Other |
Item Involved Details | Pressure Transmitter Threaded Nipple |
Installation Year | 2024 |
Manufactured Year | 2024 |
Material Involved | Carbon Steel |
Release Type | Leak |
Leak Type | Other |
Leak Type Other | Leaking Threaded Nipple |
Wildlife Impact Ind | No |
Soil Contamination | No |
Long Term Assessment | No |
Remediation Ind | No |
Water Contam Ind | No |
Could Be Hca | No |
Commodity Reached Hca | No |
Est Cost Oper Paid | 0 |
Est Cost Gas Released | 204 |
Est Cost Prop Damage | 20 |
Est Cost Emergency | 1000 |
Est Cost Environmental | 45000 |
Est Cost Other | 0 |
Prpty | 46224 |
Num Persons Hosp Not Ovnght | 0 |
Num Injured Treated By Emt | 0 |
Num Resident Building Affctd | 0 |
Num Business Building Affctd | 0 |
Accident Psig | 60 |
Mop Psig | 1400 |
Mop Cfr Section | Component Design Pressure �195.406(A)(2) View CFR 49 §192 |
Maop Established Date | 2019-05-28 00:00:00 |
Maop Reversal Flow Ind | No |
Accident Pressure | Pressure Did Not Exceed Mop |
Pressure Restriction Ind | No |
Internal Inspection Ind | No |
Other Inspection Ind | Yes |
Internal Inspection Details | Threaded Nipple On Station Piping Not On Pipeline Row |
Operation Complications Ind | Yes |
Other Complications Ind | Yes |
Inspect Comp Details | Not Designed For Tool Run |
Pipeline Function | > 20% Smys Regulated Gathering |
Scada In Place Ind | Yes |
Scada Operating Ind | Yes |
Scada Functional Ind | Yes |
Scada Detection Ind | Yes |
Scada Conf Ind | Yes |
Cpm In Place Ind | No |
Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
Investigation Status Details | No controller actions took place prior to the release |
Employee Drug Test Ind | No |
Contractor Drug Test Ind | No |
Cause | Equipment Failure |
Cause Details | Threaded Connection/coupling Failure |
Eq Failure Type | Threaded Connection/coupling Failure |
Other Stripped Ind | Pipe Nipple |
Additional Vibration Ind | Yes |
Preparer Name | G*** C********* |
Preparer Title | Regulatory Compliance Specialist Ii |
Preparer Email | G**************@o****.com |
Preparer Telephone | 9183818066 |
Prepared Date | 2025-08-14 00:00:00 |
Authorizer Name | G*** C********* |
Authorizer Telephone | 5807410185 |
Authorizer Title | Regulatory Compliance Manager |
Authorizer Email | R*********@o****.com |
Narrative | At 4:10 pcc received a call from a third party contractor about a potential leak at raptor station. Pcc began to trend data and noticed a drop in pressure then notified the local operator. Operator asked pcc to shut in the upstream and downstream valves and to shut down the station. Operator arrived on site at 6:30 and began to investigate the release. While investigating the operator discovered a broken threaded nipple fitting off the transmitter. Once pump was isolated and blocked in the operator removed the broken nipple and installed a new nipple. The transmitter was reinstalled on the new nipple and the station placed back into normal operations at 7:00. It is believed that the release was the result of vibration due to misalignment of the pump. To prevent recurrence, operations is in the process of relocating transmitters from the pipe to a nearby setting. A supplemental will be submitted once final invoices have been submitted. |