HL incident on 2025-06-12 — TX
Operator
Energy Transfer Company
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$9,815
Incident datetime
2025-06-12 19:00
Report number
Location
TX
Narrative
On 6/12/2025 at approximately 19:00, while preparing for start-up, local operations discovered a crude oil release coming from the 13002 cmar-ctol-16inch line. The line was between delivery points and already shutdown. Approximately 0.5 barrel of crude oil was released. Osros were mobilized to cleanup free product and contaminated soil. The leak was repaired by cutting out the failed below grade section. The section was replaced and rebuilt above grade. The line was started on 6/13/2025 at 11:35. The cause of the leak is still under investigation. The failed section of pipe will be sent to a third party laboratory for analysis. A supplemental report will be submitted once the investigation is complete. Supplemental & final: the investigation determined that the failure was due to internal corrosion. The cause of the internal corrosion was microbiologically induced corrosion (mic) and under-deposit corrosion. The installation of the kicker line was below grade on a crude line and did not account for prolonged periods of stagnant conditions where the line would be full of product. Line has product moved through it quarterly when maintenance pigging operations are completed. Kicker lines are not drained up and purged between pig runs. To prevent reoccurrence, the below grade kicker line was reconfigured above ground, which will allow for natural drainage and access for inspection as needed.
Detailed record list
Report Received Date
2025-07-03 00:00:00
Iyear
2025
Report Number
20250165
Supplemental Number
41571
Report Type
Supplemental Final
Operator Id
32099
Name
Energy Transfer Company
Operator Street Address
1300 Main Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2025-06-12 19:00:00
Time Zone
Eastern
Daylight Savings Ind
Yes
Location Latitude
41.666291
Location Longitude
-83.471391
Commodity Released Type
Crude Oil
Unintentional Release Bbls
0.5
Recovered Bbls
0.5
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2025-06-12 19:00:00
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
Status When Identified
Routine Start-Up
Shutdown Due Accident Ind
No
Shutdown Explain
Line Located Between Delivery Points
Communication State Fed Ind
No
On Site Datetime
2025-06-12 19:00:00
Confirmed Discovery Datetime
2025-06-12 19:55:00
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Notify Qualified Indiv Ind
Yes
Qualified Indiv Notif Datetime
2025-06-12 19:55:00
Oil Spill Removal Org Ind
Yes
Osro Activated Datetime
2025-06-12 20:24:00
Osro Arrived On Site Dt
6/12/2025 21:00
Num Pub Evacuated
0
Pipe Fac Name
York Street Station
Segment Name
13002 - 16" Marysville-Toledo
Onshore State Abbreviation
Oh
Onshore Postal Code
43605
Onshore City Name
Oregon
Onshore County Name
Lucas
Designated Location
Survey Station No.
Designated Name
0+00
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
30
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Weld, Including Heat-Affected Zone
Weld Subtype
Other Butt Weld
Installation Year
1967
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Leak Type Other
Under Investigation
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
34
Est Cost Prop Damage
9815
Est Cost Emergency
14000
Est Cost Environmental
12500
Est Cost Other
0
Prpty
36349
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
120
Mop Psig
1300
Mop Cfr Section
Subpart E Pressure Test �195.406(A)(3)
Maop Established Date
1987-04-21 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
A review of the accident determined that there were no control room actions that contributed to the event.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
Internal Corrosion
Internal External
Internal Corrosion
Int Visual Exam Results
Localized Pitting
Int Microbiological Ind
Yes
Int Metallurgical Basis Ind
Yes
Int Low Point Pipe Loc Ind
Yes
Corrosion Inhibitors
No
Corrosion Lining
No
Cleaning Dewatering
Not Applicable - Not Mainline Pipe
Corrosion Coupons
Not Applicable - Not Mainline Pipe
Other Type
Unknown
Unknown Subtype
Still Under Investigation, Cause Of Accident To Be Determined* (*supplemental Report Required)
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Pwf Design Ind
Yes
Preparer Name
T*** N*******
Preparer Title
Director - Dot Compliance
Preparer Email
T************@e*************.com
Preparer Telephone
713-989-7126
Prepared Date
2025-11-12 00:00:00
Authorizer Name
T*** N*******
Authorizer Telephone
713-989-7126
Authorizer Title
Director - Dot Compliance
Authorizer Email
T************@e*************.com
Narrative
On 6/12/2025 at approximately 19:00, while preparing for start-up, local operations discovered a crude oil release coming from the 13002 cmar-ctol-16inch line. The line was between delivery points and already shutdown. Approximately 0.5 barrel of crude oil was released. Osros were mobilized to cleanup free product and contaminated soil. The leak was repaired by cutting out the failed below grade section. The section was replaced and rebuilt above grade. The line was started on 6/13/2025 at 11:35. The cause of the leak is still under investigation. The failed section of pipe will be sent to a third party laboratory for analysis. A supplemental report will be submitted once the investigation is complete. Supplemental & final: the investigation determined that the failure was due to internal corrosion. The cause of the internal corrosion was microbiologically induced corrosion (mic) and under-deposit corrosion. The installation of the kicker line was below grade on a crude line and did not account for prolonged periods of stagnant conditions where the line would be full of product. Line has product moved through it quarterly when maintenance pigging operations are completed. Kicker lines are not drained up and purged between pig runs. To prevent reoccurrence, the below grade kicker line was reconfigured above ground, which will allow for natural drainage and access for inspection as needed.
| Report Received Date | 2025-07-03 00:00:00 |
|---|---|
| Iyear | 2025 |
| Report Number | 20250165 |
| Supplemental Number | 41571 |
| Report Type | Supplemental Final |
| Operator Id | 32099 PHMSA Enforcement |
| Name | Energy Transfer Company |
| Operator Street Address | 1300 Main Street |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2025-06-12 19:00:00 |
| Time Zone | Eastern |
| Daylight Savings Ind | Yes |
| Location Latitude | 41.666291 Google Maps OpenStreetMap |
| Location Longitude | -83.471391 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 0.5 |
| Recovered Bbls | 0.5 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Local Operating Personnel, Including Contractors |
| Operator Type | Operator Employee |
| Incident Identified Datetime | 2025-06-12 19:00:00 |
| System Part Involved | Onshore Pump/meter Station Equipment And Piping |
| On Off Shore | Onshore |
| Status When Identified | Routine Start-Up |
| Shutdown Due Accident Ind | No |
| Shutdown Explain | Line Located Between Delivery Points |
| Communication State Fed Ind | No |
| On Site Datetime | 2025-06-12 19:00:00 |
| Confirmed Discovery Datetime | 2025-06-12 19:55:00 |
| Nrc Rpt Num | Nrc Notification Not Required NRC Report How to search |
| Ignite Ind | No |
| Notify Qualified Indiv Ind | Yes |
| Qualified Indiv Notif Datetime | 2025-06-12 19:55:00 |
| Oil Spill Removal Org Ind | Yes |
| Osro Activated Datetime | 2025-06-12 20:24:00 |
| Osro Arrived On Site Dt | 6/12/2025 21:00 |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | York Street Station |
| Segment Name | 13002 - 16" Marysville-Toledo |
| Onshore State Abbreviation | Oh |
| Onshore Postal Code | 43605 |
| Onshore City Name | Oregon |
| Onshore County Name | Lucas |
| Designated Location | Survey Station No. |
| Designated Name | 0+00 |
| Federal | No |
| Location Type | Totally Contained On Operator-Controlled Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 30 |
| Crossing | No |
| Pipe Facility Type | Interstate |
| Item Involved | Weld, Including Heat-Affected Zone |
| Weld Subtype | Other Butt Weld |
| Installation Year | 1967 |
| Manufactured Year | Unknown |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Pinhole |
| Leak Type Other | Under Investigation |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | Yes |
| Soil Remed Ind | Yes |
| Water Contam Ind | No |
| Could Be Hca | Yes |
| Commodity Reached Hca | Yes |
| High Pop Ind | Yes |
| High Pop Yes No | Yes |
| Est Cost Oper Paid | 0 |
| Est Cost Gas Released | 34 |
| Est Cost Prop Damage | 9815 |
| Est Cost Emergency | 14000 |
| Est Cost Environmental | 12500 |
| Est Cost Other | 0 |
| Prpty | 36349 |
| Num Persons Hosp Not Ovnght | 0 |
| Num Injured Treated By Emt | 0 |
| Num Resident Building Affctd | 0 |
| Num Business Building Affctd | 0 |
| Accident Psig | 120 |
| Mop Psig | 1300 |
| Mop Cfr Section | Subpart E Pressure Test �195.406(A)(3) View CFR 49 §192 |
| Maop Established Date | 1987-04-21 00:00:00 |
| Maop Reversal Flow Ind | No |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | Yes |
| Cpm Operating Ind | Yes |
| Cpm Functional Ind | Yes |
| Cpm Detection Ind | No |
| Cpm Conf Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | A review of the accident determined that there were no control room actions that contributed to the event. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Corrosion Failure |
| Cause Details | Internal Corrosion |
| Internal External | Internal Corrosion |
| Int Visual Exam Results | Localized Pitting |
| Int Microbiological Ind | Yes |
| Int Metallurgical Basis Ind | Yes |
| Int Low Point Pipe Loc Ind | Yes |
| Corrosion Inhibitors | No |
| Corrosion Lining | No |
| Cleaning Dewatering | Not Applicable - Not Mainline Pipe |
| Corrosion Coupons | Not Applicable - Not Mainline Pipe |
| Other Type | Unknown |
| Unknown Subtype | Still Under Investigation, Cause Of Accident To Be Determined* (*supplemental Report Required) |
| Collected Data Ind | No |
| Has Hydrtst Conduc Before Ind | No |
| Direct Asmnt Conducted | No |
| Non Destructive Exam Ind | No |
| Pwf Design Ind | Yes |
| Preparer Name | T*** N******* |
| Preparer Title | Director - Dot Compliance |
| Preparer Email | T************@e*************.com |
| Preparer Telephone | 713-989-7126 |
| Prepared Date | 2025-11-12 00:00:00 |
| Authorizer Name | T*** N******* |
| Authorizer Telephone | 713-989-7126 |
| Authorizer Title | Director - Dot Compliance |
| Authorizer Email | T************@e*************.com |
| Narrative | On 6/12/2025 at approximately 19:00, while preparing for start-up, local operations discovered a crude oil release coming from the 13002 cmar-ctol-16inch line. The line was between delivery points and already shutdown. Approximately 0.5 barrel of crude oil was released. Osros were mobilized to cleanup free product and contaminated soil. The leak was repaired by cutting out the failed below grade section. The section was replaced and rebuilt above grade. The line was started on 6/13/2025 at 11:35. The cause of the leak is still under investigation. The failed section of pipe will be sent to a third party laboratory for analysis. A supplemental report will be submitted once the investigation is complete. Supplemental & final: the investigation determined that the failure was due to internal corrosion. The cause of the internal corrosion was microbiologically induced corrosion (mic) and under-deposit corrosion. The installation of the kicker line was below grade on a crude line and did not account for prolonged periods of stagnant conditions where the line would be full of product. Line has product moved through it quarterly when maintenance pigging operations are completed. Kicker lines are not drained up and purged between pig runs. To prevent reoccurrence, the below grade kicker line was reconfigured above ground, which will allow for natural drainage and access for inspection as needed. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA