HL incident on 2025-07-03 — TX

Operator
Energy Transfer Company
Cause
Other Accident Cause
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$4,135
Incident datetime
2025-07-03 00:00 UTC
Report number
Location
TX
Narrative
On 6/11/2025 at approximately 09:30, while operations personnel were onsite excavating for previously planned work, they discovered crude oil weeping from the 13002 cmar-ctol-16inch line. The leak was contained to the excavation site. Approximately 1 barrel of crude oil was released. Released product and contaminated soil was removed from the site. The leak was immediately repaired with a weld reinforcement sleeve and the line was returned to normal service. The failed section of pipe was cutout and replaced on 6/18. The cause of the leak is still under investigation. The failed section of pipe with the reinforcement sleeve will be sent to a third party laboratory for analysis. A supplemental report will be submitted once the investigation is complete.
Detailed record list
Report Received Date
2025-07-03 00:00:00
Iyear
2025
Report Number
20250164
Supplemental Number
41114
Report Type
Original
Operator Id
Name
Energy Transfer Company
Operator Street Address
1300 Main Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Time Zone
Eastern
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
1
Recovered Bbls
1
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
No
Shutdown Explain
Leak Was Contained To Excavation Site
Communication State Fed Ind
No
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Upstream Action Taken
Operational Control
Upstream Oprtnl Cntrl Detail
Low Level Release Was Contained And Observed In Ditch Until Repair Was Facilitated.
Downstream Action Taken
Operational Control
Downstream Oprtnl Cntrl Detail
Low Level Release Was Contained And Observed In Ditch Until Repair Was Facilitated.
Notify Qualified Indiv Ind
No
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Marysville To Toledo
Segment Name
13002 Cmar-Ctol-16inch
Onshore State Abbreviation
Mi
Onshore Postal Code
48314
Onshore City Name
Sterling Heights
Onshore County Name
Macomb
Designated Location
Survey Station No.
Designated Name
1977+25
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Exposed Due To Excavation
Depth Of Cover
120
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Repair Sleeve Or Clamp
Installation Year
1967
Manufactured Year
1967
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Other
Leak Type Other
Under Investigation
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
67
Est Cost Prop Damage
4135
Est Cost Emergency
20000
Est Cost Environmental
24799
Est Cost Other
0
Prpty
49001
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
1250
Mop Psig
1440
Mop Cfr Section
Subpart E Pressure Test �195.406(A)(3)
Maop Established Date
1987-04-21 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
A review of the accident determined that there were no control room actions that contributed to the event.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Other Accident Cause
Cause Details
Unknown
Other Type
Unknown
Unknown Subtype
Still Under Investigation, Cause Of Accident To Be Determined* (*supplemental Report Required)
Preparer Name
T*** N*******
Preparer Title
Director - Dot Compliance
Preparer Email
T************@e*************.com
Preparer Telephone
713-989-7126
Prepared Date
2025-07-03 00:00:00
Authorizer Name
T*** N*******
Authorizer Telephone
713-989-7126
Authorizer Title
Director - Dot Compliance
Authorizer Email
T************@e*************.com
Narrative
On 6/11/2025 at approximately 09:30, while operations personnel were onsite excavating for previously planned work, they discovered crude oil weeping from the 13002 cmar-ctol-16inch line. The leak was contained to the excavation site. Approximately 1 barrel of crude oil was released. Released product and contaminated soil was removed from the site. The leak was immediately repaired with a weld reinforcement sleeve and the line was returned to normal service. The failed section of pipe was cutout and replaced on 6/18. The cause of the leak is still under investigation. The failed section of pipe with the reinforcement sleeve will be sent to a third party laboratory for analysis. A supplemental report will be submitted once the investigation is complete.
Report Received Date 2025-07-03 00:00:00
Iyear 2025
Report Number 20250164
Supplemental Number 41114
Report Type Original
Operator Id 32099 PHMSA Enforcement
Name Energy Transfer Company
Operator Street Address 1300 Main Street
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77002
Time Zone Eastern
Daylight Savings Ind Yes
Location Latitude 42.607071 Google Maps OpenStreetMap
Location Longitude -83.041651 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 1
Recovered Bbls 1
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Operator Employee
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind No
Shutdown Explain Leak Was Contained To Excavation Site
Communication State Fed Ind No
Nrc Rpt Num Nrc Notification Not Required NRC Report How to search
Ignite Ind No
Upstream Action Taken Operational Control
Upstream Oprtnl Cntrl Detail Low Level Release Was Contained And Observed In Ditch Until Repair Was Facilitated.
Downstream Action Taken Operational Control
Downstream Oprtnl Cntrl Detail Low Level Release Was Contained And Observed In Ditch Until Repair Was Facilitated.
Notify Qualified Indiv Ind No
Oil Spill Removal Org Ind No
Num Pub Evacuated 0
Pipe Fac Name Marysville To Toledo
Segment Name 13002 Cmar-Ctol-16inch
Onshore State Abbreviation Mi
Onshore Postal Code 48314
Onshore City Name Sterling Heights
Onshore County Name Macomb
Designated Location Survey Station No.
Designated Name 1977+25
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Exposed Due To Excavation
Depth Of Cover 120
Crossing No
Pipe Facility Type Interstate
Item Involved Repair Sleeve Or Clamp
Installation Year 1967
Manufactured Year 1967
Material Involved Carbon Steel
Release Type Leak
Leak Type Other
Leak Type Other Under Investigation
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind Yes
Soil Remed Ind Yes
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca Yes
High Pop Ind Yes
High Pop Yes No Yes
Est Cost Oper Paid 0
Est Cost Gas Released 67
Est Cost Prop Damage 4135
Est Cost Emergency 20000
Est Cost Environmental 24799
Est Cost Other 0
Prpty 49001
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 1250
Mop Psig 1440
Mop Cfr Section Subpart E Pressure Test �195.406(A)(3) View CFR 49 §192
Maop Established Date 1987-04-21 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind No
Cpm Conf Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details A review of the accident determined that there were no control room actions that contributed to the event.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Other Accident Cause
Cause Details Unknown
Other Type Unknown
Unknown Subtype Still Under Investigation, Cause Of Accident To Be Determined* (*supplemental Report Required)
Preparer Name T*** N*******
Preparer Title Director - Dot Compliance
Preparer Email T************@e*************.com
Preparer Telephone 713-989-7126
Prepared Date 2025-07-03 00:00:00
Authorizer Name T*** N*******
Authorizer Telephone 713-989-7126
Authorizer Title Director - Dot Compliance
Authorizer Email T************@e*************.com
Narrative On 6/11/2025 at approximately 09:30, while operations personnel were onsite excavating for previously planned work, they discovered crude oil weeping from the 13002 cmar-ctol-16inch line. The leak was contained to the excavation site. Approximately 1 barrel of crude oil was released. Released product and contaminated soil was removed from the site. The leak was immediately repaired with a weld reinforcement sleeve and the line was returned to normal service. The failed section of pipe was cutout and replaced on 6/18. The cause of the leak is still under investigation. The failed section of pipe with the reinforcement sleeve will be sent to a third party laboratory for analysis. A supplemental report will be submitted once the investigation is complete.