HL incident on 2025-06-30 — TX

Operator
Crestwood Midstream Partners Lp
Cause
Other Accident Cause
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$25,000
Incident datetime
2025-06-30 00:00 UTC
Report number
Location
TX
Narrative
On 06/06/25 at approximately 17:35, an operator employee discovered a small fire on pump c3 in the pump room. The fire was immediately extinguished with a fire extinguisher. Operations discovered crude oil leaking from a seal on the 8inch 100 line inside arrow central delivery point (cdp). Approximately 1 gallon of crude oil was released. A small amount of product was consumed by the fire. The remaining product was cleaned-up by local personnel. The pump was removed and flanges blinded. The pump has been sent to a third party for analysis, inspection and repair. The line was restarted on 06/07/25 at 07:50. The cause of the accident is still under investigation by a third party. A supplemental report will be submitted once the investigation is complete.
Detailed record list
Report Received Date
2025-06-30 00:00:00
Iyear
2025
Report Number
20250158
Supplemental Number
41089
Report Type
Original
Operator Id
Name
Crestwood Midstream Partners Lp
Operator Street Address
1300 Main Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
0.1
Recovered Bbls
0.1
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Communication State Fed Ind
No
Nrc Rpt Num
Additional Nrc Report Numbers
1433488
Ignite Ind
Yes
How Extinguished
Operator/contractor
Consumed By Fire In Barrels
0.1
Explode Ind
No
Notify Qualified Indiv Ind
Yes
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Arrow Central Delivery Point
Segment Name
8-Inch 100 Line
Onshore State Abbreviation
Nd
Onshore Postal Code
58847
Onshore City Name
Not Within A Municipality
Onshore County Name
Mckenzie
Designated Location
Survey Station No.
Designated Name
0+00
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Inside A Building
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pump
Pump Type
Centrifugal
Pump Service Type
Injection
Installation Year
2018
Manufactured Year
2018
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Seal Or Packing
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
5
Est Cost Prop Damage
25000
Est Cost Emergency
100
Est Cost Environmental
0
Est Cost Other
0
Prpty
25105
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
256
Mop Psig
740
Mop Cfr Section
Four Hour Test Or Operation �195.406(A)(5)
Maop Established Date
2017-04-13 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
A review of the accident determined that there were no control room actions that contributed to the event.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Other Accident Cause
Cause Details
Unknown
Other Type
Unknown
Unknown Subtype
Still Under Investigation, Cause Of Accident To Be Determined* (*supplemental Report Required)
Preparer Name
T*** N*******
Preparer Title
Director - Dot Compliance
Preparer Email
T************@e*************.com
Preparer Telephone
713-989-7126
Prepared Date
2025-06-30 00:00:00
Authorizer Name
T*** N*******
Authorizer Telephone
713-989-7126
Authorizer Title
Director - Dot Compliance
Authorizer Email
T************@e*************.com
Narrative
On 06/06/25 at approximately 17:35, an operator employee discovered a small fire on pump c3 in the pump room. The fire was immediately extinguished with a fire extinguisher. Operations discovered crude oil leaking from a seal on the 8inch 100 line inside arrow central delivery point (cdp). Approximately 1 gallon of crude oil was released. A small amount of product was consumed by the fire. The remaining product was cleaned-up by local personnel. The pump was removed and flanges blinded. The pump has been sent to a third party for analysis, inspection and repair. The line was restarted on 06/07/25 at 07:50. The cause of the accident is still under investigation by a third party. A supplemental report will be submitted once the investigation is complete.
Report Received Date 2025-06-30 00:00:00
Iyear 2025
Report Number 20250158
Supplemental Number 41089
Report Type Original
Operator Id 39368 PHMSA Enforcement
Name Crestwood Midstream Partners Lp
Operator Street Address 1300 Main Street
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77002
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 47.80288 Google Maps OpenStreetMap
Location Longitude -102.8753 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 0.1
Recovered Bbls 0.1
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Operator Employee
System Part Involved Onshore Pump/meter Station Equipment And Piping
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind Yes
Communication State Fed Ind No
Nrc Rpt Num 1433356 NRC Report How to search
Additional Nrc Report Numbers 1433488
Ignite Ind Yes
How Extinguished Operator/contractor
Consumed By Fire In Barrels 0.1
Explode Ind No
Notify Qualified Indiv Ind Yes
Oil Spill Removal Org Ind No
Num Pub Evacuated 0
Pipe Fac Name Arrow Central Delivery Point
Segment Name 8-Inch 100 Line
Onshore State Abbreviation Nd
Onshore Postal Code 58847
Onshore City Name Not Within A Municipality
Onshore County Name Mckenzie
Designated Location Survey Station No.
Designated Name 0+00
Federal No
Location Type Totally Contained On Operator-Controlled Property
Incident Area Type Aboveground
Incident Area Subtype Inside A Building
Crossing No
Pipe Facility Type Intrastate
Item Involved Pump
Pump Type Centrifugal
Pump Service Type Injection
Installation Year 2018
Manufactured Year 2018
Material Involved Carbon Steel
Release Type Leak
Leak Type Seal Or Packing
Wildlife Impact Ind No
Soil Contamination No
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca No
Commodity Reached Hca No
Est Cost Oper Paid 0
Est Cost Gas Released 5
Est Cost Prop Damage 25000
Est Cost Emergency 100
Est Cost Environmental 0
Est Cost Other 0
Prpty 25105
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 256
Mop Psig 740
Mop Cfr Section Four Hour Test Or Operation �195.406(A)(5) View CFR 49 §192
Maop Established Date 2017-04-13 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind Yes
Scada Conf Ind No
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind No
Cpm Conf Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details A review of the accident determined that there were no control room actions that contributed to the event.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Other Accident Cause
Cause Details Unknown
Other Type Unknown
Unknown Subtype Still Under Investigation, Cause Of Accident To Be Determined* (*supplemental Report Required)
Preparer Name T*** N*******
Preparer Title Director - Dot Compliance
Preparer Email T************@e*************.com
Preparer Telephone 713-989-7126
Prepared Date 2025-06-30 00:00:00
Authorizer Name T*** N*******
Authorizer Telephone 713-989-7126
Authorizer Title Director - Dot Compliance
Authorizer Email T************@e*************.com
Narrative On 06/06/25 at approximately 17:35, an operator employee discovered a small fire on pump c3 in the pump room. The fire was immediately extinguished with a fire extinguisher. Operations discovered crude oil leaking from a seal on the 8inch 100 line inside arrow central delivery point (cdp). Approximately 1 gallon of crude oil was released. A small amount of product was consumed by the fire. The remaining product was cleaned-up by local personnel. The pump was removed and flanges blinded. The pump has been sent to a third party for analysis, inspection and repair. The line was restarted on 06/07/25 at 07:50. The cause of the accident is still under investigation by a third party. A supplemental report will be submitted once the investigation is complete.

All rights reserved. Copyright © by ClearPHMSA