HL incident on 2025-06-16 — TX

Operator
Holly Energy Partners - Operating, L.p.
Cause
Corrosion Failure
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$5
Incident datetime
2025-06-16 00:00 UTC
Report number
Location
TX
Narrative
On 5/15/25 air patrol reported a dark spot over a segment of piping on the trust 6/8 pipeline system. 32.750259, -99.673802 estimated size 40 feet x 10 feet. At 15:20 cst, the technician confirmed that gasoline was present on the ground surface at that location. The control room was immediately notified and shutdown and blocked in the system. Additional local operations personnel were dispatched by the assets qi. Shorty thereafter the osro was activated and was deployed to the location. Once safe conditions were met - excavation was started and the pipe was uncovered, field examination uncovered a pinhole leak in between the 12 & 11 o'clock position of the pipe. A clamp was applied to further isolate the leak.
Detailed record list
Report Received Date
2025-06-16 00:00:00
Iyear
2025
Report Number
20250146
Supplemental Number
41026
Report Type
Original
Operator Id
Name
Holly Energy Partners - Operating, L.p.
Operator Street Address
2323 Victory Ave. Suite 1400
Operator City Name
Dallas
Operator State Abbreviation
TX
Operator Postal Code
75219
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Gasoline (Non-Ethanol)
Unintentional Release Bbls
25
Recovered Bbls
10
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Air Patrol
Operator Type
Contractor Working For The Operator
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Communication State Fed Ind
No
Nrc Rpt Num
Additional Nrc Report Numbers
1431369
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Type Ind
Manual
Downstream Action Taken
Valve Closure
Downstream Valve Type Ind
Manual
Notify Qualified Indiv Ind
Yes
Oil Spill Removal Org Ind
Yes
Osro Arrived On Site Dt
5/15/2025 22:50
Num Pub Evacuated
0
Pipe Fac Name
Trust 6/8
Segment Name
Hwy 180
Onshore State Abbreviation
Tx
Onshore Postal Code
79533
Onshore City Name
Not Within A Municipality
Onshore County Name
Jones
Designated Location
Milepost
Designated Name
218
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
5
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Body
Puddle Weld Ind
No
Pipe Diameter
6.625
Pipe Wall Thickness
0.188
Pipe Smys
42000
Pipe Specification
X42
Pipe Seam Type
Erw - Low Frequency
Pipe Manufacturer
Unknown
Pipe Coating Type
Fusion Bonded Epoxy(Fbe)
Coating Applied Ind
Unknown
Installation Year
Unknown
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
5
Est Cost Gas Released
5
Est Cost Prop Damage
5
Est Cost Emergency
5
Est Cost Environmental
5
Est Cost Other
5
Est Cost Other Details
Tbd - Unknown At This Time
Prpty
30
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
770
Mop Psig
1440
Mop Cfr Section
Subpart E Pressure Test �195.406(A)(3)
Maop Established Date
2006-04-26 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
41184
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Corrosion was the cause not operator error
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Galvanic Corrosion Ind
Yes
Field Exam Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
1960
Shielding Evident
Yes
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Close Interval Survey Ind
Yes
Cp Annual Survey Year
2024
Close Interval Survey Year
2020
Prior Damage
Yes
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Cir Trn Wave Mgn Flx Lkg Ind
Yes
Axial Recent Year
2025
Axial Rcnt Propul Method
Free Swimming
Axial Rcnt Attuned Detect
Metal Loss
Axial Rcnt Atnd Dtct Metal
High Resolution
Axial Previous Year
2022
Axial Prev Propul Method
Free Swimming
Axial Prev Attuned Detect
Metal Loss
Axial Prev Atnd Dtct Metal
High Resolution
Circ Wave Recent Year
2025
Circ Wv Rcnt Propul Method
Free Swimming
Circ Wv Rcnt Resolution
High Resolution
Circ Wv Previous Year
2022
Circ Wv Prev Propul Method
Free Swimming
Circ Wv Prev Resolution
High Resolution
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
2006
Hydrtst Most Rcnt Pressure
1515
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Extrnl Cor Galvanic Ind
Yes
Preparer Name
C****** C***
Preparer Title
Director Pipeline Excellence And Compliance
Preparer Email
C***********@h*********.com
Preparer Telephone
505-273-0339
Prepared Date
2025-06-16 00:00:00
Authorizer Name
C****** C***
Authorizer Telephone
505-273-0339
Authorizer Email
C***********@h*********.com
Narrative
On 5/15/25 air patrol reported a dark spot over a segment of piping on the trust 6/8 pipeline system. 32.750259, -99.673802 estimated size 40 feet x 10 feet. At 15:20 cst, the technician confirmed that gasoline was present on the ground surface at that location. The control room was immediately notified and shutdown and blocked in the system. Additional local operations personnel were dispatched by the assets qi. Shorty thereafter the osro was activated and was deployed to the location. Once safe conditions were met - excavation was started and the pipe was uncovered, field examination uncovered a pinhole leak in between the 12 & 11 o'clock position of the pipe. A clamp was applied to further isolate the leak.
Report Received Date 2025-06-16 00:00:00
Iyear 2025
Report Number 20250146
Supplemental Number 41026
Report Type Original
Operator Id 32011 PHMSA Enforcement
Name Holly Energy Partners - Operating, L.p.
Operator Street Address 2323 Victory Ave. Suite 1400
Operator City Name Dallas
Operator State Abbreviation TX
Operator Postal Code 75219
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 32.750259 Google Maps OpenStreetMap
Location Longitude -99.673802 Google Maps OpenStreetMap
Commodity Released Type Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype Gasoline (Non-Ethanol)
Unintentional Release Bbls 25
Recovered Bbls 10
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Air Patrol
Operator Type Contractor Working For The Operator
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind Yes
Communication State Fed Ind No
Nrc Rpt Num 1431192 NRC Report How to search
Additional Nrc Report Numbers 1431369
Ignite Ind No
Upstream Action Taken Valve Closure
Upstream Valve Type Ind Manual
Downstream Action Taken Valve Closure
Downstream Valve Type Ind Manual
Notify Qualified Indiv Ind Yes
Oil Spill Removal Org Ind Yes
Osro Arrived On Site Dt 5/15/2025 22:50
Num Pub Evacuated 0
Pipe Fac Name Trust 6/8
Segment Name Hwy 180
Onshore State Abbreviation Tx
Onshore Postal Code 79533
Onshore City Name Not Within A Municipality
Onshore County Name Jones
Designated Location Milepost
Designated Name 218
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 5
Crossing No
Pipe Facility Type Intrastate
Item Involved Pipe
Pipe Type Pipe Body
Puddle Weld Ind No
Pipe Diameter 6.625
Pipe Wall Thickness 0.188
Pipe Smys 42000
Pipe Specification X42
Pipe Seam Type Erw - Low Frequency
Pipe Manufacturer Unknown
Pipe Coating Type Fusion Bonded Epoxy(Fbe)
Coating Applied Ind Unknown
Installation Year Unknown
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind Yes
Soil Remed Ind Yes
Water Contam Ind No
Could Be Hca No
Commodity Reached Hca No
Est Cost Oper Paid 5
Est Cost Gas Released 5
Est Cost Prop Damage 5
Est Cost Emergency 5
Est Cost Environmental 5
Est Cost Other 5
Est Cost Other Details Tbd - Unknown At This Time
Prpty 30
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 770
Mop Psig 1440
Mop Cfr Section Subpart E Pressure Test �195.406(A)(3) View CFR 49 §192
Maop Established Date 2006-04-26 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 41184
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind No
Cpm Conf Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details Corrosion was the cause not operator error
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details External Corrosion
Internal External External Corrosion
Visual Exam Results Localized Pitting
Galvanic Corrosion Ind Yes
Field Exam Basis Ind Yes
Underground Location Yes
Under Cathodic Protection Ind Yes
Cathodic Pro Start Year 1960
Shielding Evident Yes
Cathodic Survey Type Yes
Cp Annual Survey Ind Yes
Close Interval Survey Ind Yes
Cp Annual Survey Year 2024
Close Interval Survey Year 2020
Prior Damage Yes
Collected Data Ind Yes
Axial Magnetic Flx Lkg Ind Yes
Cir Trn Wave Mgn Flx Lkg Ind Yes
Axial Recent Year 2025
Axial Rcnt Propul Method Free Swimming
Axial Rcnt Attuned Detect Metal Loss
Axial Rcnt Atnd Dtct Metal High Resolution
Axial Previous Year 2022
Axial Prev Propul Method Free Swimming
Axial Prev Attuned Detect Metal Loss
Axial Prev Atnd Dtct Metal High Resolution
Circ Wave Recent Year 2025
Circ Wv Rcnt Propul Method Free Swimming
Circ Wv Rcnt Resolution High Resolution
Circ Wv Previous Year 2022
Circ Wv Prev Propul Method Free Swimming
Circ Wv Prev Resolution High Resolution
Has Hydrtst Conduc Before Ind Yes
Hydrtst Most Rcnt Year 2006
Hydrtst Most Rcnt Pressure 1515
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Extrnl Cor Galvanic Ind Yes
Preparer Name C****** C***
Preparer Title Director Pipeline Excellence And Compliance
Preparer Email C***********@h*********.com
Preparer Telephone 505-273-0339
Prepared Date 2025-06-16 00:00:00
Authorizer Name C****** C***
Authorizer Telephone 505-273-0339
Authorizer Email C***********@h*********.com
Narrative On 5/15/25 air patrol reported a dark spot over a segment of piping on the trust 6/8 pipeline system. 32.750259, -99.673802 estimated size 40 feet x 10 feet. At 15:20 cst, the technician confirmed that gasoline was present on the ground surface at that location. The control room was immediately notified and shutdown and blocked in the system. Additional local operations personnel were dispatched by the assets qi. Shorty thereafter the osro was activated and was deployed to the location. Once safe conditions were met - excavation was started and the pipe was uncovered, field examination uncovered a pinhole leak in between the 12 & 11 o'clock position of the pipe. A clamp was applied to further isolate the leak.

All rights reserved. Copyright © by ClearPHMSA