GTG incident on 2025-08-01 — MI

Operator
Dtm Appalachia Gathering, Llc
Cause
Equipment Failure
Commodity
Natural Gas
Program
GTG
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$0
Incident datetime
2025-08-01 00:00 UTC
Report number
Location
MI
Narrative
A significant operational change occurred at dt midstream�s major delivery point for ags. Flow was cut significantly with no notification to dtm which caused ags pressure to rise. The relief valve on the discharge of the cooper�s run dehy lifted when the pressure reached 1160 psig (setpoint 1218 psig per previous inspection). The relief functioned properly other than the slightly early lift. Dtm was alerted by a production contractor working in the area. Dtm's on-call technician went to site, verified system pressure was under maop, and shut the relief block valve to reset the relief. They then monitored the relief to ensure no repeat releases occurred. The relief was function tested and confirmed to be lifting at 1160 psig. The setpoint was reset to 1218 psig and successfully function tested and returned to service.
Detailed record list
Report Received Date
2025-08-01 00:00:00
Iyear
2025
Report Number
20250084
Supplemental Number
41200
Report Type
Supplemental Final
Operator Id
Name
Dtm Appalachia Gathering, Llc
Operator Street Address
500 Woodward Ave Suite 2900
Operator City Name
Detroit
Operator State Abbreviation
MI
Operator Postal Code
48226
Time Zone
Eastern
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Nrc Rpt Num
Additional Nrc Report Numbers
1436930
Commodity Released Type
Natural Gas
Unintentional Release
7400
Intentional Release
0
Accompanying Liquid
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Status When Identified
Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind
No
Shutdown Explain
Relief Valve Was Reset. System Still Operating Below Maop.
Communication State Fed Ind
No
Ignite Ind
No
Upstream Oprtnl Cntrl Detail
Relief Which Lifted Early Was Shut In And Reset. Maop Was Not Exceeded.
Downstream Oprtnl Cntrl Detail
Relief Which Lifted Early Was Shut In And Reset. Maop Was Not Exceeded.
Num Pub Evacuated
0
On Off Shore
Onshore
Onshore State Abbreviation
Wv
Onshore Postal Code
26521
Onshore City Name
Not Within A Municipality
Onshore County Name
Monongalia
Designated Location
Not Applicable
Pipe Fac Name
Cooper's Run Dehy
Segment Name
Appalachia Gathering System
Federal
No
Location Type
Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Intrastate
System Part Involved
Onshore Compressor Station Equipment And Piping
Item Involved
Dehydrator/drier/treater/scrubber
Installation Year
Unknown
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Other
Release Type Details
Relief Valve Actuation.
Class Location Type
Class 1 Location
Could Be Hca
No
Pir Radius
578
Heat Damage Ind
No
Non Heat Damage Ind
No
Did Occur In Mca Ind
No
Est Cost Oper Paid
0
Est Cost Unintentional Release
25012
Est Cost Intentional Release
0
Est Cost Prop Damage
0
Est Cost Emergency
1580
Est Cost Other
0
Gas Cost In Mcf
3.38
Prpty
26592
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Wildlife Impact Ind
No
Accident Psig
1160
Gas Flow In Pipe In Mcf
60000
Mop Psig
1218
Mop Cfr Section
192.619(A)(2)
Maop Established Date
2013-11-13 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Maop
Pressure Restriction Ind
No
Gas Required Odorized Ind
No
Pipeline Function
Type C Gathering
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Accident Identifier
Notification From Public
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
No visibility over relief valve position. System pressure was under alarm limits.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Malfunction Of Control/relief Equipment
Eq Failure Type
Malfunction Of Control/relief Equipment
Relief Valve Ind
Yes
Eq Additional Other Ind
Yes
Eq Additional Other Details
Setpoint Drift.
Preparer Name
K*** D********
Preparer Title
Specialist
Preparer Email
K*************@d**********.com
Preparer Telephone
8107282233
Local Contact Name
S**** W*********
Local Contact Email
S****************@d**********.com
Local Contact Telephone
3042762929
Authorizer Name
P***** C******
Authorizer Title
Director Of Codes And Regulatory
Authorizer Telephone
(313) 774-2406
Authorizer Email
P*************@d**********.com
Narrative
A significant operational change occurred at dt midstream�s major delivery point for ags. Flow was cut significantly with no notification to dtm which caused ags pressure to rise. The relief valve on the discharge of the cooper�s run dehy lifted when the pressure reached 1160 psig (setpoint 1218 psig per previous inspection). The relief functioned properly other than the slightly early lift. Dtm was alerted by a production contractor working in the area. Dtm's on-call technician went to site, verified system pressure was under maop, and shut the relief block valve to reset the relief. They then monitored the relief to ensure no repeat releases occurred. The relief was function tested and confirmed to be lifting at 1160 psig. The setpoint was reset to 1218 psig and successfully function tested and returned to service.
Report Received Date 2025-08-01 00:00:00
Iyear 2025
Report Number 20250084
Supplemental Number 41200
Report Type Supplemental Final
Operator Id 39003 PHMSA Enforcement
Name Dtm Appalachia Gathering, Llc
Operator Street Address 500 Woodward Ave Suite 2900
Operator City Name Detroit
Operator State Abbreviation MI
Operator Postal Code 48226
Time Zone Eastern
Daylight Savings Ind Yes
Location Latitude 39.702296 Google Maps OpenStreetMap
Location Longitude -80.19848 Google Maps OpenStreetMap
Nrc Rpt Num 1436736 NRC Report How to search
Additional Nrc Report Numbers 1436930
Commodity Released Type Natural Gas
Unintentional Release 7400
Intentional Release 0
Accompanying Liquid 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Status When Identified Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind No
Shutdown Explain Relief Valve Was Reset. System Still Operating Below Maop.
Communication State Fed Ind No
Ignite Ind No
Upstream Oprtnl Cntrl Detail Relief Which Lifted Early Was Shut In And Reset. Maop Was Not Exceeded.
Downstream Oprtnl Cntrl Detail Relief Which Lifted Early Was Shut In And Reset. Maop Was Not Exceeded.
Num Pub Evacuated 0
On Off Shore Onshore
Onshore State Abbreviation Wv
Onshore Postal Code 26521
Onshore City Name Not Within A Municipality
Onshore County Name Monongalia
Designated Location Not Applicable
Pipe Fac Name Cooper's Run Dehy
Segment Name Appalachia Gathering System
Federal No
Location Type Operator-Controlled Property
Incident Area Type Aboveground
Incident Area Subtype Typical Aboveground Facility Piping Or Appurtenance
Crossing No
Pipe Facility Type Intrastate
System Part Involved Onshore Compressor Station Equipment And Piping
Item Involved Dehydrator/drier/treater/scrubber
Installation Year Unknown
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Other
Release Type Details Relief Valve Actuation.
Class Location Type Class 1 Location
Could Be Hca No
Pir Radius 578
Heat Damage Ind No
Non Heat Damage Ind No
Did Occur In Mca Ind No
Est Cost Oper Paid 0
Est Cost Unintentional Release 25012
Est Cost Intentional Release 0
Est Cost Prop Damage 0
Est Cost Emergency 1580
Est Cost Other 0
Gas Cost In Mcf 3.38
Prpty 26592
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Wildlife Impact Ind No
Accident Psig 1160
Gas Flow In Pipe In Mcf 60000
Mop Psig 1218
Mop Cfr Section 192.619(A)(2) View CFR 49 §192
Maop Established Date 2013-11-13 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Maop
Pressure Restriction Ind No
Gas Required Odorized Ind No
Pipeline Function Type C Gathering
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Accident Identifier Notification From Public
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details No visibility over relief valve position. System pressure was under alarm limits.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Equipment Failure
Cause Details Malfunction Of Control/relief Equipment
Eq Failure Type Malfunction Of Control/relief Equipment
Relief Valve Ind Yes
Eq Additional Other Ind Yes
Eq Additional Other Details Setpoint Drift.
Preparer Name K*** D********
Preparer Title Specialist
Preparer Email K*************@d**********.com
Preparer Telephone 8107282233
Local Contact Name S**** W*********
Local Contact Email S****************@d**********.com
Local Contact Telephone 3042762929
Authorizer Name P***** C******
Authorizer Title Director Of Codes And Regulatory
Authorizer Telephone (313) 774-2406
Authorizer Email P*************@d**********.com
Narrative A significant operational change occurred at dt midstream�s major delivery point for ags. Flow was cut significantly with no notification to dtm which caused ags pressure to rise. The relief valve on the discharge of the cooper�s run dehy lifted when the pressure reached 1160 psig (setpoint 1218 psig per previous inspection). The relief functioned properly other than the slightly early lift. Dtm was alerted by a production contractor working in the area. Dtm's on-call technician went to site, verified system pressure was under maop, and shut the relief block valve to reset the relief. They then monitored the relief to ensure no repeat releases occurred. The relief was function tested and confirmed to be lifting at 1160 psig. The setpoint was reset to 1218 psig and successfully function tested and returned to service.

All rights reserved. Copyright © by ClearPHMSA