Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2025-03-20 — TX
Operator
Enterprise Products Operating Llc
Cause
Equipment Failure
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$78,000
Incident datetime
2025-03-20 00:00 UTC
Report number
Location
TX
Narrative
On 2/18/2025 at approximately 14:00 cst, an enterprise permian terminal control room operator received an alarm of the sump tank level rising. Enterprise pipeline technician was dispatched to investigate and discovered the psv on the discharge piping unseated and 2 bbls of diesel released on the ground. The psv was lo/to and placed out of service. Nrc reportable on 3/19/2025 based on cost of replacement. Operations made a decision to purchase a new valve in order to regain operational status.
Detailed record list
Report Received Date
2025-03-20 00:00:00
Iyear
2025
Report Number
20250068
Supplemental Number
40891
Report Type
Supplemental Final
Operator Id
31618
Name
Enterprise Products Operating Llc
Operator Street Address
1100 Louisiana Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Time Zone
Central
Daylight Savings Ind
No
Location Latitude
32.77148
Location Longitude
-102.96029
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Diesel, Fuel Oil, Kerosene, Jet Fuel
Unintentional Release Bbls
2
Recovered Bbls
2
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
System Part Involved
Onshore Terminal/tank Farm Equipment And Piping
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
No
Shutdown Explain
Stayed Within Safe Operation
Communication State Fed Ind
No
Nrc Rpt Num
1426304
Additional Nrc Report Numbers
1426371
Ignite Ind
No
Notify Qualified Indiv Ind
No
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
South Leg
Segment Name
Permian Terminal
Onshore State Abbreviation
Tx
Onshore Postal Code
79360
Onshore City Name
Semiole
Onshore County Name
Gaines
Designated Location
Milepost
Designated Name
Mp 0
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Valve
Valve Type
Relief Valve
Installation Year
2024
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Other
Release Type Details
Psv Was Leaking Due To A Missing O-Ring
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
10
Est Cost Prop Damage
78000
Est Cost Emergency
0
Est Cost Environmental
0
Est Cost Other
0
Prpty
78010
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
1350
Mop Psig
1480
Mop Cfr Section
Internal Design Pressure �195.406(A)(1)
Maop Established Date
1980-01-01 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
No actions were taken for an investigation of the control room
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Malfunction Of Control/relief Equipment
Eq Failure Type
Malfunction Of Control/relief Equipment
Relief Valve Ind
Yes
Eq Additional Other Ind
Yes
Eq Additional Other Details
Post Accident Review Showed Missing O-Ring
Preparer Name
A***** A******** I*
Preparer Title
Pipeline Compliance Engineer
Preparer Email
A***********@e****.com
Preparer Telephone
7133813659
Prepared Date
2025-05-14 00:00:00
Authorizer Name
A***** A******** I*
Authorizer Telephone
7133813659
Authorizer Title
Pipeline Compliance Engineer
Authorizer Email
A***********@e****.com
Narrative
On 2/18/2025 at approximately 14:00 cst, an enterprise permian terminal control room operator received an alarm of the sump tank level rising. Enterprise pipeline technician was dispatched to investigate and discovered the psv on the discharge piping unseated and 2 bbls of diesel released on the ground. The psv was lo/to and placed out of service. Nrc reportable on 3/19/2025 based on cost of replacement. Operations made a decision to purchase a new valve in order to regain operational status.
Report Received Date | 2025-03-20 00:00:00 |
---|---|
Iyear | 2025 |
Report Number | 20250068 |
Supplemental Number | 40891 |
Report Type | Supplemental Final |
Operator Id | 31618 PHMSA Enforcement |
Name | Enterprise Products Operating Llc |
Operator Street Address | 1100 Louisiana Street |
Operator City Name | Houston |
Operator State Abbreviation | TX |
Operator Postal Code | 77002 |
Time Zone | Central |
Daylight Savings Ind | No |
Location Latitude | 32.77148 Google Maps OpenStreetMap |
Location Longitude | -102.96029 Google Maps OpenStreetMap |
Commodity Released Type | Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions |
Commodity Subtype | Diesel, Fuel Oil, Kerosene, Jet Fuel |
Unintentional Release Bbls | 2 |
Recovered Bbls | 2 |
Fatality Ind | No |
Fatal | 0 |
Injury Ind | No |
Injure | 0 |
Accident Identifier | Local Operating Personnel, Including Contractors |
Operator Type | Operator Employee |
System Part Involved | Onshore Terminal/tank Farm Equipment And Piping |
On Off Shore | Onshore |
Status When Identified | Normal Operation, Includes Pauses Between Batches And During Maintenance |
Shutdown Due Accident Ind | No |
Shutdown Explain | Stayed Within Safe Operation |
Communication State Fed Ind | No |
Nrc Rpt Num | 1426304 NRC Report How to search |
Additional Nrc Report Numbers | 1426371 |
Ignite Ind | No |
Notify Qualified Indiv Ind | No |
Oil Spill Removal Org Ind | No |
Num Pub Evacuated | 0 |
Pipe Fac Name | South Leg |
Segment Name | Permian Terminal |
Onshore State Abbreviation | Tx |
Onshore Postal Code | 79360 |
Onshore City Name | Semiole |
Onshore County Name | Gaines |
Designated Location | Milepost |
Designated Name | Mp 0 |
Federal | No |
Location Type | Totally Contained On Operator-Controlled Property |
Incident Area Type | Aboveground |
Incident Area Subtype | Typical Aboveground Facility Piping Or Appurtenance |
Crossing | No |
Pipe Facility Type | Interstate |
Item Involved | Valve |
Valve Type | Relief Valve |
Installation Year | 2024 |
Manufactured Year | Unknown |
Material Involved | Carbon Steel |
Release Type | Other |
Release Type Details | Psv Was Leaking Due To A Missing O-Ring |
Wildlife Impact Ind | No |
Soil Contamination | No |
Long Term Assessment | No |
Remediation Ind | No |
Water Contam Ind | No |
Could Be Hca | No |
Commodity Reached Hca | No |
Est Cost Oper Paid | 0 |
Est Cost Gas Released | 10 |
Est Cost Prop Damage | 78000 |
Est Cost Emergency | 0 |
Est Cost Environmental | 0 |
Est Cost Other | 0 |
Prpty | 78010 |
Num Persons Hosp Not Ovnght | 0 |
Num Injured Treated By Emt | 0 |
Num Resident Building Affctd | 0 |
Num Business Building Affctd | 0 |
Accident Psig | 1350 |
Mop Psig | 1480 |
Mop Cfr Section | Internal Design Pressure �195.406(A)(1) View CFR 49 §192 |
Maop Established Date | 1980-01-01 00:00:00 |
Maop Reversal Flow Ind | No |
Accident Pressure | Pressure Did Not Exceed Mop |
Pressure Restriction Ind | No |
Pipeline Function | > 20% Smys Regulated Transmission |
Scada In Place Ind | Yes |
Scada Operating Ind | Yes |
Scada Functional Ind | Yes |
Scada Detection Ind | No |
Scada Conf Ind | No |
Cpm In Place Ind | Yes |
Cpm Operating Ind | Yes |
Cpm Functional Ind | Yes |
Cpm Detection Ind | No |
Cpm Conf Ind | No |
Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
Investigation Status Details | No actions were taken for an investigation of the control room |
Employee Drug Test Ind | No |
Contractor Drug Test Ind | No |
Cause | Equipment Failure |
Cause Details | Malfunction Of Control/relief Equipment |
Eq Failure Type | Malfunction Of Control/relief Equipment |
Relief Valve Ind | Yes |
Eq Additional Other Ind | Yes |
Eq Additional Other Details | Post Accident Review Showed Missing O-Ring |
Preparer Name | A***** A******** I* |
Preparer Title | Pipeline Compliance Engineer |
Preparer Email | A***********@e****.com |
Preparer Telephone | 7133813659 |
Prepared Date | 2025-05-14 00:00:00 |
Authorizer Name | A***** A******** I* |
Authorizer Telephone | 7133813659 |
Authorizer Title | Pipeline Compliance Engineer |
Authorizer Email | A***********@e****.com |
Narrative | On 2/18/2025 at approximately 14:00 cst, an enterprise permian terminal control room operator received an alarm of the sump tank level rising. Enterprise pipeline technician was dispatched to investigate and discovered the psv on the discharge piping unseated and 2 bbls of diesel released on the ground. The psv was lo/to and placed out of service. Nrc reportable on 3/19/2025 based on cost of replacement. Operations made a decision to purchase a new valve in order to regain operational status. |
External Resources