Incident details
Operator, cause, commodity and consequences with raw source fields.
GD incident on 2025-09-18 — GA
Operator
Atlanta Gas Light Co
Cause
Excavation Issue
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$123
Incident datetime
2025-09-18 12:17
Report number
Location
GA, FULTON
Narrative
A third-party party excavator (meer electric) struck and damaged an atlanta gas light company (aglc) 2-inch plastic gas main while horizontal directionally drilling to install a new water service to 22 habersham way, atlanta, ga. The escaping gas traveled along the bore path from the main to the outside building wall of the residence where the gas ignited, resulting in extensive fire damage to the residence. Upon arrival, aglc personnel worked with emergency responders to secure the area and monitor the surrounding area for gas. Gas was shut off to the damaged area by performing two squeeze-off operations on the two-way feed main. The excavator was performing the excavation activities under an emergency locate ticket and did not pothole and spot the natural gas facilities prior to commencing excavation activities. The gas main was correctly marked at the point of damage. On the day of the incident, aglc recognized the potential damage estimates likely met or exceeded the $149,700 threshold and thus met the criteria for being reportable to the nrc. However, the company did not have reason to estimate the damages to meet or exceed the $1 million threshold for csb reporting. As a result, aglc reported this incident to the nrc under report #1443076 and the 48-hr follow up filed under report #1443201 but did not report it to the csb. On october 14, 2024, after learning that the homeowner�s insurance company reserved the property loss at $3 million, agl notified the csb of the incident.
Detailed record list
Occurred At
2025-09-18 12:17:00
Year
2025
Report Received Date
2025-10-18 00:00:00
Iyear
2025.0
Report Number
20250058.0
Supplemental Number
41483.0
Report Type
Original Final
Operator Id
Name
Atlanta Gas Light Co
Operator Street Address
10 Peachtree Place Ne
Operator City Name
Atlanta
Operator State Abbreviation
GA
Operator Postal Code
30309
Local Datetime
2025-09-18 13:37:00
Time Zone
Eastern
Daylight Savings Ind
Yes
Location Street Address
22 Habersham Way Nw
Location City Name
Atlanta
Location County Name
Fulton
Location State Abbreviation
GA
Location Postal Code
30305
Location Latitude
33.834378
Location Longitude
-84.394016
Flow Cont Squeeze Off Ind
Yes
Nrc Rpt Datetime
2025-09-18 14:13:00
Nrc Rpt Num
1443076
Additional Nrc Report Numbers
1443201
Commodity Released Type
Natural Gas
Unintentional Release
5.7
Intentional Release
0.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
Yes
Ignite Datetime
2025-09-18 12:17:00
How Extinguished
Local/state/federal Emergency Responder
Gas Consumed By Fire In Mcf
5.7
Explode Ind
No
Num Pub Evacuated
0.0
Incident Identified Datetime
2025-09-18 12:17:00
On Site Datetime
2025-09-18 12:35:00
Confirmed Discovery Datetime
2025-09-18 12:35:00
Federal
No
Location Type
Public Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
48.0
Other Underground Facilities
No
Crossing
No
Pipe Facility Type
Investor Owned
System Part Involved
Main
Installation Year
2002.0
Pipe Diameter
2.0
Pipe Specification
Astm D2513
Pipe Manufacturer
Unknown
Material Involved
Plastic
Plastic Type
Polyethylene (Pe)
Plastic Sdr
11
Material Pe Pipe Code
2406
Release Type
Mechanical Puncture
Puncture Axial
0.1
Puncture Circum
0.5
Class Location Type
Class 3 Location
Est Cost Oper Paid
3000000.0
Est Cost Prop Damage
123.0
Est Cost Emergency
6542.0
Est Cost Other
0.0
Gas Cost In Mcf
3.39
Est Cost Unintentional Release
19.0
Est Cost Intentional Release
0.0
Prpty
3006684.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
1.0
Num Persons Hosp Not Ovnght
0.0
Num Injured Treated By Emt
0.0
Num Resident Building Affctd
0.0
Num Business Building Affctd
0.0
Accident Psig
40.0
Normal Psig
40.0
Mop Psig
45.0
Mop Cfr Section
192.619(A)(2)
Maop Established Date
2002-01-22 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
Injection Pump
Gas Odorized Level
9.5
Scada In Place Ind
No
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
Yes
One Call System Ind
Yes
State Law Exempt Ind
No
Notify Cga Dirt
Yes
Public Row Ind
Yes
Public Subtype
City Street
Joint Trench Ind
No
Cross Bore Ind
No
Depth Of Grade
> 36�
Excavator Type
Contractor
Excavator Equipment
Directional Drilling
Work Performed
Water
One Call Notified Ind
Yes
One Call Ticket Num
2.50918e+11
White Lined Ind
No
Locator Type
Contract Locator
Visible Marks
Yes
Service Interruption
Yes
Service Interruption Hours
1.0
Root Cause Category
Excavation Issue
Root Cause Type
Excavator Dug Prior To Verifying Marks By Test-Hole (Pothole)
Preparer Name
R**** M*******
Preparer Title
Principal Compliance Engineer
Preparer Email
R*******@s*********.com
Preparer Telephone
(404) 584-3733
Preparer Fax
(404) 584-4710
Authorizer Name
J** C****
Authorizer Title
Manager Compliance And Qa
Authorizer Telephone
(404) 460-7894
Authorizer Email
J******@s*********.com
Narrative
A third-party party excavator (meer electric) struck and damaged an atlanta gas light company (aglc) 2-inch plastic gas main while horizontal directionally drilling to install a new water service to 22 habersham way, atlanta, ga. The escaping gas traveled along the bore path from the main to the outside building wall of the residence where the gas ignited, resulting in extensive fire damage to the residence. Upon arrival, aglc personnel worked with emergency responders to secure the area and monitor the surrounding area for gas. Gas was shut off to the damaged area by performing two squeeze-off operations on the two-way feed main. The excavator was performing the excavation activities under an emergency locate ticket and did not pothole and spot the natural gas facilities prior to commencing excavation activities. The gas main was correctly marked at the point of damage. On the day of the incident, aglc recognized the potential damage estimates likely met or exceeded the $149,700 threshold and thus met the criteria for being reportable to the nrc. However, the company did not have reason to estimate the damages to meet or exceed the $1 million threshold for csb reporting. As a result, aglc reported this incident to the nrc under report #1443076 and the 48-hr follow up filed under report #1443201 but did not report it to the csb. On october 14, 2024, after learning that the homeowner�s insurance company reserved the property loss at $3 million, agl notified the csb of the incident.
| Occurred At | 2025-09-18 12:17:00 |
|---|---|
| Year | 2025 |
| Report Received Date | 2025-10-18 00:00:00 |
| Iyear | 2025.0 |
| Report Number | 20250058.0 |
| Supplemental Number | 41483.0 |
| Report Type | Original Final |
| Operator Id | 792 PHMSA Enforcement |
| Name | Atlanta Gas Light Co |
| Operator Street Address | 10 Peachtree Place Ne |
| Operator City Name | Atlanta |
| Operator State Abbreviation | GA |
| Operator Postal Code | 30309 |
| Local Datetime | 2025-09-18 13:37:00 |
| Time Zone | Eastern |
| Daylight Savings Ind | Yes |
| Location Street Address | 22 Habersham Way Nw |
| Location City Name | Atlanta |
| Location County Name | Fulton |
| Location State Abbreviation | GA |
| Location Postal Code | 30305 |
| Location Latitude | 33.834378 Google Maps OpenStreetMap |
| Location Longitude | -84.394016 Google Maps OpenStreetMap |
| Flow Cont Squeeze Off Ind | Yes |
| Nrc Rpt Datetime | 2025-09-18 14:13:00 |
| Nrc Rpt Num | 1443076 NRC Report How to search |
| Additional Nrc Report Numbers | 1443201 |
| Commodity Released Type | Natural Gas |
| Unintentional Release | 5.7 |
| Intentional Release | 0.0 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Ignite Ind | Yes |
| Ignite Datetime | 2025-09-18 12:17:00 |
| How Extinguished | Local/state/federal Emergency Responder |
| Gas Consumed By Fire In Mcf | 5.7 |
| Explode Ind | No |
| Num Pub Evacuated | 0.0 |
| Incident Identified Datetime | 2025-09-18 12:17:00 |
| On Site Datetime | 2025-09-18 12:35:00 |
| Confirmed Discovery Datetime | 2025-09-18 12:35:00 |
| Federal | No |
| Location Type | Public Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 48.0 |
| Other Underground Facilities | No |
| Crossing | No |
| Pipe Facility Type | Investor Owned |
| System Part Involved | Main |
| Installation Year | 2002.0 |
| Pipe Diameter | 2.0 |
| Pipe Specification | Astm D2513 |
| Pipe Manufacturer | Unknown |
| Material Involved | Plastic |
| Plastic Type | Polyethylene (Pe) |
| Plastic Sdr | 11 |
| Material Pe Pipe Code | 2406 |
| Release Type | Mechanical Puncture |
| Puncture Axial | 0.1 |
| Puncture Circum | 0.5 |
| Class Location Type | Class 3 Location |
| Est Cost Oper Paid | 3000000.0 |
| Est Cost Prop Damage | 123.0 |
| Est Cost Emergency | 6542.0 |
| Est Cost Other | 0.0 |
| Gas Cost In Mcf | 3.39 |
| Est Cost Unintentional Release | 19.0 |
| Est Cost Intentional Release | 0.0 |
| Prpty | 3006684.0 |
| Commercial Affected | 0.0 |
| Industrial Affected | 0.0 |
| Residences Affected | 1.0 |
| Num Persons Hosp Not Ovnght | 0.0 |
| Num Injured Treated By Emt | 0.0 |
| Num Resident Building Affctd | 0.0 |
| Num Business Building Affctd | 0.0 |
| Accident Psig | 40.0 |
| Normal Psig | 40.0 |
| Mop Psig | 45.0 |
| Mop Cfr Section | 192.619(A)(2) View CFR 49 §192 |
| Maop Established Date | 2002-01-22 00:00:00 |
| Accident Pressure | Pressure Did Not Exceed Maop |
| Gas Odorized System Type | Injection Pump |
| Gas Odorized Level | 9.5 |
| Scada In Place Ind | No |
| Accident Identifier | Notification From Emergency Responder |
| Investigation Status | No, the facility was not monitored by a controller(s) at the time of the incident |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Excavation Damage |
| Cause Details | Excavation Damage By Third Party |
| Ex Party Type | Excavation Damage By Third Party |
| Prior Notification Ind | Yes |
| One Call System Ind | Yes |
| State Law Exempt Ind | No |
| Notify Cga Dirt | Yes |
| Public Row Ind | Yes |
| Public Subtype | City Street |
| Joint Trench Ind | No |
| Cross Bore Ind | No |
| Depth Of Grade | > 36� |
| Excavator Type | Contractor |
| Excavator Equipment | Directional Drilling |
| Work Performed | Water |
| One Call Notified Ind | Yes |
| One Call Ticket Num | 2.50918e+11 |
| White Lined Ind | No |
| Locator Type | Contract Locator |
| Visible Marks | Yes |
| Service Interruption | Yes |
| Service Interruption Hours | 1.0 |
| Root Cause Category | Excavation Issue |
| Root Cause Type | Excavator Dug Prior To Verifying Marks By Test-Hole (Pothole) |
| Preparer Name | R**** M******* |
| Preparer Title | Principal Compliance Engineer |
| Preparer Email | R*******@s*********.com |
| Preparer Telephone | (404) 584-3733 |
| Preparer Fax | (404) 584-4710 |
| Authorizer Name | J** C**** |
| Authorizer Title | Manager Compliance And Qa |
| Authorizer Telephone | (404) 460-7894 |
| Authorizer Email | J******@s*********.com |
| Narrative | A third-party party excavator (meer electric) struck and damaged an atlanta gas light company (aglc) 2-inch plastic gas main while horizontal directionally drilling to install a new water service to 22 habersham way, atlanta, ga. The escaping gas traveled along the bore path from the main to the outside building wall of the residence where the gas ignited, resulting in extensive fire damage to the residence. Upon arrival, aglc personnel worked with emergency responders to secure the area and monitor the surrounding area for gas. Gas was shut off to the damaged area by performing two squeeze-off operations on the two-way feed main. The excavator was performing the excavation activities under an emergency locate ticket and did not pothole and spot the natural gas facilities prior to commencing excavation activities. The gas main was correctly marked at the point of damage. On the day of the incident, aglc recognized the potential damage estimates likely met or exceeded the $149,700 threshold and thus met the criteria for being reportable to the nrc. However, the company did not have reason to estimate the damages to meet or exceed the $1 million threshold for csb reporting. As a result, aglc reported this incident to the nrc under report #1443076 and the 48-hr follow up filed under report #1443201 but did not report it to the csb. On october 14, 2024, after learning that the homeowner�s insurance company reserved the property loss at $3 million, agl notified the csb of the incident. |