GD incident on 2025-07-06 — IL

Operator
Northern Illinois Gas Co
Cause
Locating Issue
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$17,200
Incident datetime
2025-07-06 00:00 UTC
Report number
Location
IL, KENDALL
Narrative
While grading the area, the grader struck the gas main releasing gas to atmosphere. The released gas ignited damaging the grader and an additional two pieces of construction equipment. The fire service responded to the incident. Nicor gas was contacted and responded to the incident. The fire was contained to area of the damage and was allowed to burn by the fire service. The fire was extinguished soon after nicor gas crews stopped the gas flow at three locations away from the fire.
Detailed record list
Report Received Date
2025-07-06 00:00:00
Iyear
2025.0
Report Number
20250039.0
Supplemental Number
41119.0
Report Type
Original
Operator Id
Name
Northern Illinois Gas Co
Operator Street Address
P.o. Box 190, Rt 59 & I-88
Operator City Name
Aurora
Operator State Abbreviation
IL
Operator Postal Code
60507.0
Time Zone
Central
Daylight Savings Ind
Yes
Location Street Address
Wolf's Crossing Rd And 5th St
Location City Name
Oswego
Location County Name
Kendall
Location State Abbreviation
IL
Location Postal Code
60543.0
Location Latitude
Location Longitude
Flow Cont Squeeze Off Ind
Yes
Flow Cont Stopple Fitng Ind
Yes
Nrc Rpt Num
Additional Nrc Report Numbers
1433523.0
Commodity Released Type
Natural Gas
Unintentional Release
2329.0
Intentional Release
0.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
Yes
How Extinguished
Other
How Extinguished Other Detail
Flow Control Cut Off Fuel (Natural Gas) To The Fire At The Damage Location.
Gas Consumed By Fire In Mcf
2329
Explode Ind
No
Num Pub Evacuated
0.0
Federal
No
Location Type
Public Property
Incident Area Type
Underground
Incident Area Subtype
Exposed Due To Excavation
Depth Of Cover
1.0
Other Underground Facilities
No
Crossing
No
Pipe Facility Type
Investor Owned
System Part Involved
Main
Installation Year
2025.0
Pipe Diameter
6.0
Pipe Specification
Astm D3350
Pipe Manufacturer
Unknown
Material Involved
Plastic
Plastic Type
Polyethylene (Pe)
Plastic Sdr
21
Material Pe Pipe Code
2708
Release Type
Mechanical Puncture
Puncture Axial
36.0
Puncture Circum
10.0
Class Location Type
Class 3 Location
Est Cost Oper Paid
500000.0
Est Cost Prop Damage
17200.0
Est Cost Emergency
16500.0
Est Cost Other
0.0
Gas Cost In Mcf
5.4
Est Cost Unintentional Release
12577.0
Est Cost Intentional Release
0.0
Prpty
546277.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
0.0
Num Persons Hosp Not Ovnght
0.0
Num Injured Treated By Emt
0.0
Num Resident Building Affctd
0.0
Num Business Building Affctd
0.0
Accident Psig
55.0
Normal Psig
55.0
Mop Psig
60.0
Mop Cfr Section
192.619(A)(2)
Maop Established Date
2025-04-18 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
Combination Of Odorization Types
Gas Odorized Lvl Not Msrd Ind
Yes
Scada In Place Ind
No
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
Yes
One Call System Ind
Yes
State Law Exempt Ind
No
Notify Cga Dirt
No
Public Row Ind
Yes
Public Subtype
City Street
Joint Trench Ind
No
Cross Bore Ind
No
Depth Of Grade
< 18�
Excavator Type
Developer
Excavator Equipment
Grader/scraper
Work Performed
Grading
One Call Notified Ind
Yes
One Call Center Name
J.u.l.i.e. (Illinois)
White Lined Ind
Yes
Locator Type
Contract Locator
Visible Marks
No
Service Interruption
No
Root Cause Category
Locating Issue
Root Cause Type
Facility Not Marked Due To Incorrect Facility Records/maps
Preparer Name
J*** L* D******
Preparer Title
Manager - Operations Quality Assurance
Preparer Email
J******@s*********.com
Preparer Telephone
6309184934
Local Contact Name
J*** L* D******
Local Contact Email
J******@s*********.com
Local Contact Telephone
6309184934
Authorizer Name
J*** L* D******
Authorizer Title
Manager - Operations Quality Assurance
Authorizer Telephone
6309184934
Authorizer Email
J******@s*********.com
Narrative
While grading the area, the grader struck the gas main releasing gas to atmosphere. The released gas ignited damaging the grader and an additional two pieces of construction equipment. The fire service responded to the incident. Nicor gas was contacted and responded to the incident. The fire was contained to area of the damage and was allowed to burn by the fire service. The fire was extinguished soon after nicor gas crews stopped the gas flow at three locations away from the fire.
Report Received Date 2025-07-06 00:00:00
Iyear 2025.0
Report Number 20250039.0
Supplemental Number 41119.0
Report Type Original
Operator Id 13710 PHMSA Enforcement
Name Northern Illinois Gas Co
Operator Street Address P.o. Box 190, Rt 59 & I-88
Operator City Name Aurora
Operator State Abbreviation IL
Operator Postal Code 60507.0
Time Zone Central
Daylight Savings Ind Yes
Location Street Address Wolf's Crossing Rd And 5th St
Location City Name Oswego
Location County Name Kendall
Location State Abbreviation IL
Location Postal Code 60543.0
Location Latitude 41.692107 Google Maps OpenStreetMap
Location Longitude -88.292867 Google Maps OpenStreetMap
Flow Cont Squeeze Off Ind Yes
Flow Cont Stopple Fitng Ind Yes
Nrc Rpt Num 1433337.0 NRC Report How to search
Additional Nrc Report Numbers 1433523.0
Commodity Released Type Natural Gas
Unintentional Release 2329.0
Intentional Release 0.0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Ignite Ind Yes
How Extinguished Other
How Extinguished Other Detail Flow Control Cut Off Fuel (Natural Gas) To The Fire At The Damage Location.
Gas Consumed By Fire In Mcf 2329
Explode Ind No
Num Pub Evacuated 0.0
Federal No
Location Type Public Property
Incident Area Type Underground
Incident Area Subtype Exposed Due To Excavation
Depth Of Cover 1.0
Other Underground Facilities No
Crossing No
Pipe Facility Type Investor Owned
System Part Involved Main
Installation Year 2025.0
Pipe Diameter 6.0
Pipe Specification Astm D3350
Pipe Manufacturer Unknown
Material Involved Plastic
Plastic Type Polyethylene (Pe)
Plastic Sdr 21
Material Pe Pipe Code 2708
Release Type Mechanical Puncture
Puncture Axial 36.0
Puncture Circum 10.0
Class Location Type Class 3 Location
Est Cost Oper Paid 500000.0
Est Cost Prop Damage 17200.0
Est Cost Emergency 16500.0
Est Cost Other 0.0
Gas Cost In Mcf 5.4
Est Cost Unintentional Release 12577.0
Est Cost Intentional Release 0.0
Prpty 546277.0
Commercial Affected 0.0
Industrial Affected 0.0
Residences Affected 0.0
Num Persons Hosp Not Ovnght 0.0
Num Injured Treated By Emt 0.0
Num Resident Building Affctd 0.0
Num Business Building Affctd 0.0
Accident Psig 55.0
Normal Psig 55.0
Mop Psig 60.0
Mop Cfr Section 192.619(A)(2) View CFR 49 §192
Maop Established Date 2025-04-18 00:00:00
Accident Pressure Pressure Did Not Exceed Maop
Gas Odorized System Type Combination Of Odorization Types
Gas Odorized Lvl Not Msrd Ind Yes
Scada In Place Ind No
Accident Identifier Notification From Emergency Responder
Investigation Status No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Excavation Damage
Cause Details Excavation Damage By Third Party
Ex Party Type Excavation Damage By Third Party
Prior Notification Ind Yes
One Call System Ind Yes
State Law Exempt Ind No
Notify Cga Dirt No
Public Row Ind Yes
Public Subtype City Street
Joint Trench Ind No
Cross Bore Ind No
Depth Of Grade < 18�
Excavator Type Developer
Excavator Equipment Grader/scraper
Work Performed Grading
One Call Notified Ind Yes
One Call Center Name J.u.l.i.e. (Illinois)
White Lined Ind Yes
Locator Type Contract Locator
Visible Marks No
Service Interruption No
Root Cause Category Locating Issue
Root Cause Type Facility Not Marked Due To Incorrect Facility Records/maps
Preparer Name J*** L* D******
Preparer Title Manager - Operations Quality Assurance
Preparer Email J******@s*********.com
Preparer Telephone 6309184934
Local Contact Name J*** L* D******
Local Contact Email J******@s*********.com
Local Contact Telephone 6309184934
Authorizer Name J*** L* D******
Authorizer Title Manager - Operations Quality Assurance
Authorizer Telephone 6309184934
Authorizer Email J******@s*********.com
Narrative While grading the area, the grader struck the gas main releasing gas to atmosphere. The released gas ignited damaging the grader and an additional two pieces of construction equipment. The fire service responded to the incident. Nicor gas was contacted and responded to the incident. The fire was contained to area of the damage and was allowed to burn by the fire service. The fire was extinguished soon after nicor gas crews stopped the gas flow at three locations away from the fire.

All rights reserved. Copyright © by ClearPHMSA