Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2024-12-20 — TX
Operator
Enterprise Products Operating Llc
Cause
Incorrect Operation
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$300,000
Incident datetime
2024-12-20 00:00 UTC
Report number
Location
TX
Narrative
At approximately 19:45 cst, enterprise operator at eldorado terminal observed the receipt header psv was relieving during a delivery from the p80 pipeline. The valve at the tank into which p80 was supposed to deliver was closed. The tank booster pump was damaged and caused the release of estimated 3 gallons of gasoline. Nrc was notified on the basis of estimated pump repair costs exceeding $50,000. This accident is still under investigation. Nrc #1417552, 48-hour update #1417628
Detailed record list
Report Received Date
2024-12-20 00:00:00
Iyear
2024
Report Number
20240296
Supplemental Number
40347
Report Type
Original
Operator Id
31618
Name
Enterprise Products Operating Llc
Operator Street Address
1100 Louisiana Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Time Zone
Central
Daylight Savings Ind
No
Location Latitude
33.251808
Location Longitude
-92.617642
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Gasoline (Non-Ethanol)
Unintentional Release Bbls
0.1
Recovered Bbls
0.1
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
System Part Involved
Onshore Terminal/tank Farm Equipment And Piping
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
No
Shutdown Explain
Pipeline Delivery Was Rerouted To A Different Tank, Avoiding Damaged Pump.
Communication State Fed Ind
No
Nrc Rpt Num
1417552
Additional Nrc Report Numbers
1417628
Ignite Ind
No
Notify Qualified Indiv Ind
No
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Eldorado Terminal
Segment Name
Lid P80 Fitch To Eldorado #1
Onshore State Abbreviation
Ar
Onshore Postal Code
71730
Onshore City Name
Eldorado
Onshore County Name
Union
Designated Location
Milepost
Designated Name
53.979
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pump
Pump Type
Centrifugal
Pump Service Type
Other
Pump Service Type Details
Terminal Tank Booster Pump
Installation Year
Unknown
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Other
Release Type Details
Overpressure
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
Usa Drinking Ind
Yes
Usa Drinking Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
6
Est Cost Prop Damage
300000
Est Cost Emergency
500
Est Cost Environmental
0
Est Cost Other
0
Prpty
300506
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
125
Mop Psig
285
Mop Cfr Section
Subpart E Pressure Test �195.406(A)(3)
Maop Established Date
1996-12-19 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Neither controller nor control room contributed to the accident.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Incorrect Operation
Cause Details
Pipeline Or Equipment Overpressured
Operation Type
Pipeline Or Equipment Overpressured
Related Other Ind
Yes
Operation Related Details
Incomplete Training
Category Type
Normal Operating Conditions
Operator Qualification Ind
Yes
Qualified Individuals
No, But They Were Performing The Task(S) Under The Direction And Observation Of A Qualified Individual
Preparer Name
T****** A**********
Preparer Title
Senior Staff Pipeline Compliance Engineer
Preparer Email
T**********@e****.com
Preparer Telephone
713-381-6433
Prepared Date
2024-12-20 00:00:00
Local Contact Name
T****** A* G********
Local Contact Email
T**********@e****.com
Local Contact Telephone
713-381-6433
Authorizer Name
T****** A* G********
Authorizer Telephone
713-381-6433
Authorizer Title
Senior Staff Pipeline Compliance Engineer
Authorizer Email
T**********@e****.com
Narrative
At approximately 19:45 cst, enterprise operator at eldorado terminal observed the receipt header psv was relieving during a delivery from the p80 pipeline. The valve at the tank into which p80 was supposed to deliver was closed. The tank booster pump was damaged and caused the release of estimated 3 gallons of gasoline. Nrc was notified on the basis of estimated pump repair costs exceeding $50,000. This accident is still under investigation. Nrc #1417552, 48-hour update #1417628
Report Received Date | 2024-12-20 00:00:00 |
---|---|
Iyear | 2024 |
Report Number | 20240296 |
Supplemental Number | 40347 |
Report Type | Original |
Operator Id | 31618 PHMSA Enforcement |
Name | Enterprise Products Operating Llc |
Operator Street Address | 1100 Louisiana Street |
Operator City Name | Houston |
Operator State Abbreviation | TX |
Operator Postal Code | 77002 |
Time Zone | Central |
Daylight Savings Ind | No |
Location Latitude | 33.251808 Google Maps OpenStreetMap |
Location Longitude | -92.617642 Google Maps OpenStreetMap |
Commodity Released Type | Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions |
Commodity Subtype | Gasoline (Non-Ethanol) |
Unintentional Release Bbls | 0.1 |
Recovered Bbls | 0.1 |
Fatality Ind | No |
Fatal | 0 |
Injury Ind | No |
Injure | 0 |
Accident Identifier | Local Operating Personnel, Including Contractors |
Operator Type | Operator Employee |
System Part Involved | Onshore Terminal/tank Farm Equipment And Piping |
On Off Shore | Onshore |
Status When Identified | Normal Operation, Includes Pauses Between Batches And During Maintenance |
Shutdown Due Accident Ind | No |
Shutdown Explain | Pipeline Delivery Was Rerouted To A Different Tank, Avoiding Damaged Pump. |
Communication State Fed Ind | No |
Nrc Rpt Num | 1417552 NRC Report How to search |
Additional Nrc Report Numbers | 1417628 |
Ignite Ind | No |
Notify Qualified Indiv Ind | No |
Oil Spill Removal Org Ind | No |
Num Pub Evacuated | 0 |
Pipe Fac Name | Eldorado Terminal |
Segment Name | Lid P80 Fitch To Eldorado #1 |
Onshore State Abbreviation | Ar |
Onshore Postal Code | 71730 |
Onshore City Name | Eldorado |
Onshore County Name | Union |
Designated Location | Milepost |
Designated Name | 53.979 |
Federal | No |
Location Type | Totally Contained On Operator-Controlled Property |
Incident Area Type | Aboveground |
Incident Area Subtype | Typical Aboveground Facility Piping Or Appurtenance |
Crossing | No |
Pipe Facility Type | Interstate |
Item Involved | Pump |
Pump Type | Centrifugal |
Pump Service Type | Other |
Pump Service Type Details | Terminal Tank Booster Pump |
Installation Year | Unknown |
Manufactured Year | Unknown |
Material Involved | Carbon Steel |
Release Type | Other |
Release Type Details | Overpressure |
Wildlife Impact Ind | No |
Soil Contamination | No |
Long Term Assessment | No |
Remediation Ind | No |
Water Contam Ind | No |
Could Be Hca | Yes |
Commodity Reached Hca | Yes |
Usa Drinking Ind | Yes |
Usa Drinking Yes No | Yes |
Est Cost Oper Paid | 0 |
Est Cost Gas Released | 6 |
Est Cost Prop Damage | 300000 |
Est Cost Emergency | 500 |
Est Cost Environmental | 0 |
Est Cost Other | 0 |
Prpty | 300506 |
Num Persons Hosp Not Ovnght | 0 |
Num Injured Treated By Emt | 0 |
Num Resident Building Affctd | 0 |
Num Business Building Affctd | 0 |
Accident Psig | 125 |
Mop Psig | 285 |
Mop Cfr Section | Subpart E Pressure Test �195.406(A)(3) View CFR 49 §192 |
Maop Established Date | 1996-12-19 00:00:00 |
Maop Reversal Flow Ind | No |
Accident Pressure | Pressure Did Not Exceed Mop |
Pressure Restriction Ind | No |
Pipeline Function | > 20% Smys Regulated Transmission |
Scada In Place Ind | Yes |
Scada Operating Ind | Yes |
Scada Functional Ind | Yes |
Scada Detection Ind | No |
Scada Conf Ind | No |
Cpm In Place Ind | Yes |
Cpm Operating Ind | Yes |
Cpm Functional Ind | Yes |
Cpm Detection Ind | No |
Cpm Conf Ind | No |
Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
Investigation Status Details | Neither controller nor control room contributed to the accident. |
Employee Drug Test Ind | No |
Contractor Drug Test Ind | No |
Cause | Incorrect Operation |
Cause Details | Pipeline Or Equipment Overpressured |
Operation Type | Pipeline Or Equipment Overpressured |
Related Other Ind | Yes |
Operation Related Details | Incomplete Training |
Category Type | Normal Operating Conditions |
Operator Qualification Ind | Yes |
Qualified Individuals | No, But They Were Performing The Task(S) Under The Direction And Observation Of A Qualified Individual |
Preparer Name | T****** A********** |
Preparer Title | Senior Staff Pipeline Compliance Engineer |
Preparer Email | T**********@e****.com |
Preparer Telephone | 713-381-6433 |
Prepared Date | 2024-12-20 00:00:00 |
Local Contact Name | T****** A* G******** |
Local Contact Email | T**********@e****.com |
Local Contact Telephone | 713-381-6433 |
Authorizer Name | T****** A* G******** |
Authorizer Telephone | 713-381-6433 |
Authorizer Title | Senior Staff Pipeline Compliance Engineer |
Authorizer Email | T**********@e****.com |
Narrative | At approximately 19:45 cst, enterprise operator at eldorado terminal observed the receipt header psv was relieving during a delivery from the p80 pipeline. The valve at the tank into which p80 was supposed to deliver was closed. The tank booster pump was damaged and caused the release of estimated 3 gallons of gasoline. Nrc was notified on the basis of estimated pump repair costs exceeding $50,000. This accident is still under investigation. Nrc #1417552, 48-hour update #1417628 |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA