HL incident on 2024-11-27 — TX

Operator
Plains Pipeline Midcon Llc
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$32,230
Incident datetime
2024-11-27 00:00 UTC
Report number
Location
TX
Narrative
Approximately 200 barrels of crude oil were released from the orion to stockholm 8inch pipeline. The date and time of the release (part a q4) are indicative of the earliest possible time the release could have started based on control center data. The cause and preventative measure for the release are under investigation and a supplemental report will be submitted. Supplemental: the date/time provided in part a q4 were determined during the investigation into the release; there were no activities on 10/26/2024 which may have contributed to the release. The potential release was discovered by a controller monitoring the system in the control center, and the release was later confirmed by personnel in the field. The nrc notification was placed within one-hour of discovering estimated costs were expected to exceed $50,000. The cause of the release is attributed to internal corrosion as result of microbiologically induced bacteria (mic). To prevent future incidents, plains cut out, replaced, performed an in-line inspection (ili), and will take further mitigative action as needed based on the ili report.
Detailed record list
Report Received Date
2024-11-27 00:00:00
Iyear
2024
Report Number
20240282
Supplemental Number
40397
Report Type
Supplemental Final
Operator Id
Name
Plains Pipeline Midcon Llc
Operator Street Address
333 Clay Street, Suite 1900
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
200
Recovered Bbls
200
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Controller
Operator Type
Operator Employee
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Nrc Rpt Num
Additional Nrc Report Numbers
1415347
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Type Ind
Remotely Controlled
Downstream Action Taken
Valve Closure
Downstream Valve Type Ind
Manual
Notify Qualified Indiv Ind
Yes
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Orion To Stockholm 8 Inch
Segment Name
Orion To Stockholm 8 Inch
Onshore State Abbreviation
Ok
Onshore Postal Code
73848
Onshore City Name
Laverne
Onshore County Name
Harper
Designated Location
Milepost
Designated Name
0+4.4mi
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
42
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Puddle Weld Ind
No
Pipe Diameter
8
Pipe Wall Thickness
0.188
Pipe Smys
52000
Pipe Specification
Api 5l
Pipe Seam Type
Erw - Low Frequency
Pipe Manufacturer
Unknown
Pipe Coating Type
Coal Tar
Coating Applied Ind
Yes
Installation Year
1960
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
10000
Est Cost Gas Released
12250
Est Cost Prop Damage
32230
Est Cost Emergency
7000
Est Cost Environmental
155500
Est Cost Other
0
Prpty
216980
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
45
Mop Psig
1250
Mop Cfr Section
Subpart E Pressure Test �195.406(A)(3)
Maop Established Date
2016-01-01 00:00:00
Maop Reversal Flow Ind
Bi-Directional
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
96360
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
Yes
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
Yes
Cpm Conf Ind
Yes
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest No Schedule Ind
Yes
Invest No Schedule Ind Details
No Indications That The Controller Contributed To Or Caused The Incident
Invest No Control Room Ind
Yes
Invest No Controller Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
Internal Corrosion
Internal External
Internal Corrosion
Int Visual Exam Results
Localized Pitting
Int Microbiological Ind
Yes
Int Metallurgical Basis Ind
Yes
Int Low Point Pipe Loc Ind
Yes
Corrosion Inhibitors
Yes
Corrosion Lining
No
Cleaning Dewatering
Yes
Corrosion Coupons
Yes
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Axial Recent Year
2021
Axial Rcnt Propul Method
Free Swimming
Axial Rcnt Attuned Detect
Metal Loss
Axial Rcnt Atnd Dtct Metal
High Resolution
Axial Previous Year
2018
Axial Prev Propul Method
Free Swimming
Axial Prev Attuned Detect
Metal Loss
Axial Prev Atnd Dtct Metal
High Resolution
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
2016
Hydrtst Most Rcnt Pressure
1986
Direct Asmnt Conducted
No
Non Destructive Exam Ind
Yes
Exm Handl Ultrasonic Rcnt Year
2021
Exm Handl Ultrasonic Rcnt Ind
Yes
Preparer Name
N****** A G*******
Preparer Title
Hse Regulatory Compliance Supervisor
Preparer Email
N***************@p*****.com
Preparer Telephone
7136464376
Prepared Date
2025-01-10 00:00:00
Local Contact Name
N****** A G*******
Local Contact Email
N***************@p*****.com
Local Contact Telephone
7136464376
Authorizer Name
N****** A G*******
Authorizer Telephone
7136464376
Authorizer Title
Hse Regulatory Compliance Supervisor
Authorizer Email
N***************@p*****.com
Narrative
Approximately 200 barrels of crude oil were released from the orion to stockholm 8inch pipeline. The date and time of the release (part a q4) are indicative of the earliest possible time the release could have started based on control center data. The cause and preventative measure for the release are under investigation and a supplemental report will be submitted. Supplemental: the date/time provided in part a q4 were determined during the investigation into the release; there were no activities on 10/26/2024 which may have contributed to the release. The potential release was discovered by a controller monitoring the system in the control center, and the release was later confirmed by personnel in the field. The nrc notification was placed within one-hour of discovering estimated costs were expected to exceed $50,000. The cause of the release is attributed to internal corrosion as result of microbiologically induced bacteria (mic). To prevent future incidents, plains cut out, replaced, performed an in-line inspection (ili), and will take further mitigative action as needed based on the ili report.
Report Received Date 2024-11-27 00:00:00
Iyear 2024
Report Number 20240282
Supplemental Number 40397
Report Type Supplemental Final
Operator Id 40498 PHMSA Enforcement
Name Plains Pipeline Midcon Llc
Operator Street Address 333 Clay Street, Suite 1900
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77002
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 36.66959 Google Maps OpenStreetMap
Location Longitude -99.64398 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 200
Recovered Bbls 200
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Controller
Operator Type Operator Employee
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind Yes
Communication State Fed Ind Yes
Party Initiated Communication Operator
Nrc Rpt Num 1415230 NRC Report How to search
Additional Nrc Report Numbers 1415347
Ignite Ind No
Upstream Action Taken Valve Closure
Upstream Valve Type Ind Remotely Controlled
Downstream Action Taken Valve Closure
Downstream Valve Type Ind Manual
Notify Qualified Indiv Ind Yes
Oil Spill Removal Org Ind No
Num Pub Evacuated 0
Pipe Fac Name Orion To Stockholm 8 Inch
Segment Name Orion To Stockholm 8 Inch
Onshore State Abbreviation Ok
Onshore Postal Code 73848
Onshore City Name Laverne
Onshore County Name Harper
Designated Location Milepost
Designated Name 0+4.4mi
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 42
Crossing No
Pipe Facility Type Interstate
Item Involved Pipe
Pipe Type Pipe Body
Puddle Weld Ind No
Pipe Diameter 8
Pipe Wall Thickness 0.188
Pipe Smys 52000
Pipe Specification Api 5l
Pipe Seam Type Erw - Low Frequency
Pipe Manufacturer Unknown
Pipe Coating Type Coal Tar
Coating Applied Ind Yes
Installation Year 1960
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca No
Commodity Reached Hca No
Est Cost Oper Paid 10000
Est Cost Gas Released 12250
Est Cost Prop Damage 32230
Est Cost Emergency 7000
Est Cost Environmental 155500
Est Cost Other 0
Prpty 216980
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 45
Mop Psig 1250
Mop Cfr Section Subpart E Pressure Test �195.406(A)(3) View CFR 49 §192
Maop Established Date 2016-01-01 00:00:00
Maop Reversal Flow Ind Bi-Directional
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 96360
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind Yes
Scada Conf Ind Yes
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind Yes
Cpm Conf Ind Yes
Investigation Status Yes, specify investigation result(s): (select all that apply)
Invest No Schedule Ind Yes
Invest No Schedule Ind Details No Indications That The Controller Contributed To Or Caused The Incident
Invest No Control Room Ind Yes
Invest No Controller Ind Yes
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details Internal Corrosion
Internal External Internal Corrosion
Int Visual Exam Results Localized Pitting
Int Microbiological Ind Yes
Int Metallurgical Basis Ind Yes
Int Low Point Pipe Loc Ind Yes
Corrosion Inhibitors Yes
Corrosion Lining No
Cleaning Dewatering Yes
Corrosion Coupons Yes
Collected Data Ind Yes
Axial Magnetic Flx Lkg Ind Yes
Axial Recent Year 2021
Axial Rcnt Propul Method Free Swimming
Axial Rcnt Attuned Detect Metal Loss
Axial Rcnt Atnd Dtct Metal High Resolution
Axial Previous Year 2018
Axial Prev Propul Method Free Swimming
Axial Prev Attuned Detect Metal Loss
Axial Prev Atnd Dtct Metal High Resolution
Has Hydrtst Conduc Before Ind Yes
Hydrtst Most Rcnt Year 2016
Hydrtst Most Rcnt Pressure 1986
Direct Asmnt Conducted No
Non Destructive Exam Ind Yes
Exm Handl Ultrasonic Rcnt Year 2021
Exm Handl Ultrasonic Rcnt Ind Yes
Preparer Name N****** A G*******
Preparer Title Hse Regulatory Compliance Supervisor
Preparer Email N***************@p*****.com
Preparer Telephone 7136464376
Prepared Date 2025-01-10 00:00:00
Local Contact Name N****** A G*******
Local Contact Email N***************@p*****.com
Local Contact Telephone 7136464376
Authorizer Name N****** A G*******
Authorizer Telephone 7136464376
Authorizer Title Hse Regulatory Compliance Supervisor
Authorizer Email N***************@p*****.com
Narrative Approximately 200 barrels of crude oil were released from the orion to stockholm 8inch pipeline. The date and time of the release (part a q4) are indicative of the earliest possible time the release could have started based on control center data. The cause and preventative measure for the release are under investigation and a supplemental report will be submitted. Supplemental: the date/time provided in part a q4 were determined during the investigation into the release; there were no activities on 10/26/2024 which may have contributed to the release. The potential release was discovered by a controller monitoring the system in the control center, and the release was later confirmed by personnel in the field. The nrc notification was placed within one-hour of discovering estimated costs were expected to exceed $50,000. The cause of the release is attributed to internal corrosion as result of microbiologically induced bacteria (mic). To prevent future incidents, plains cut out, replaced, performed an in-line inspection (ili), and will take further mitigative action as needed based on the ili report.

All rights reserved. Copyright © by ClearPHMSA