Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2024-11-14 — TX
Operator
Exxonmobil Pipeline Company Llc
Cause
Equipment Failure
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$700
Incident datetime
2024-11-14 00:00 UTC
Report number
Location
TX
Narrative
On october 17, 2024, a hebert tank farm operator was performing a daily station check and noticed discoloration around the tank valve on tank 3008 (gasoline service). Employees began hydro excavating below grade for observation. At 8:00 a.M. On october 18, 2024, residual could be seen in the pothole. Samples were pulled for analysis and gasoline was determined to be present. Employees then began draining the tank, which was static at the time of the release, as hydro excavation operations continued in order to determine the origin of the leak. On october 19, 2024, at 5:00 p.M. The release source was determined to be a failed valve gasket. During this event, an estimated 7 gallons (0.17 of a barrel) of gasoline were released. Throughout the event, secondary containment was maintained at the leak location. Dike wall drainage valves were locked in the closed position. The valve gasket was replaced, and the valve was reinstalled.
Detailed record list
Report Received Date
2024-11-14 00:00:00
Iyear
2024
Report Number
20240266
Supplemental Number
40220
Report Type
Original Final
Operator Id
4906
Name
Exxonmobil Pipeline Company Llc
Operator Street Address
22777 Springwoods Village Parkway E2.2b-Emp
Operator City Name
Spring
Operator State Abbreviation
TX
Operator Postal Code
77389
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
29.974028
Location Longitude
-94.0568452
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Gasoline (Non-Ethanol)
Unintentional Release Bbls
0.17
Recovered Bbls
0.17
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
System Part Involved
Onshore Breakout Tank Or Storage Vessel, Including Attached Appurtenances
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
No
Shutdown Explain
Drained And Isolated Impacted Tank. Facility Maintained Normal Run Status.
Communication State Fed Ind
No
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Notify Qualified Indiv Ind
Yes
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Hebert Tank Farm
Segment Name
Tank 3008, Valve 8
Onshore State Abbreviation
Tx
Onshore Postal Code
77705
Onshore City Name
Beaumont
Onshore County Name
Jefferson
Designated Location
Survey Station No.
Designated Name
Tk 3008, 0+00
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Tank, Including Attached Appurtenances
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Tank/vessel
Tank Vessel Subtype
Appurtenance
Tank Type
Atmospheric
Safe Fill Level
35.1
Safe Fill Level Exceeded Ind
No
Api Std Out Of Service Year
2019
Api Std In Service Year
2023
Installation Year
2019
Manufactured Year
Unknown
Material Involved
Material Other Than Carbon Steel
Material Details
Flexitallic Stainless Steel Gasket
Release Type
Leak
Leak Type
Connection Failure
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
15
Est Cost Prop Damage
700
Est Cost Emergency
900
Est Cost Environmental
0
Est Cost Other
0
Prpty
1615
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
8.75
Pressure Restriction Ind
No
Pipeline Function
< 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Leak location and volume not detectable by scada
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Non-Threaded Connection Failure
Eq Failure Type
Non-Threaded Connection Failure
Other Non Threaded Ind
Gasket
Additional Defect Ind
Yes
Preparer Name
K**** B******
Preparer Title
Pipeline Safety Advisor
Preparer Email
K************@e*********.com
Preparer Telephone
281-409-2853
Prepared Date
2024-11-13 00:00:00
Authorizer Name
L**** B******
Authorizer Telephone
281-382-6003
Authorizer Title
Regulatory Compliance Supervisor
Authorizer Email
L**************@e*********.com
Narrative
On october 17, 2024, a hebert tank farm operator was performing a daily station check and noticed discoloration around the tank valve on tank 3008 (gasoline service). Employees began hydro excavating below grade for observation. At 8:00 a.M. On october 18, 2024, residual could be seen in the pothole. Samples were pulled for analysis and gasoline was determined to be present. Employees then began draining the tank, which was static at the time of the release, as hydro excavation operations continued in order to determine the origin of the leak. On october 19, 2024, at 5:00 p.M. The release source was determined to be a failed valve gasket. During this event, an estimated 7 gallons (0.17 of a barrel) of gasoline were released. Throughout the event, secondary containment was maintained at the leak location. Dike wall drainage valves were locked in the closed position. The valve gasket was replaced, and the valve was reinstalled.
Report Received Date | 2024-11-14 00:00:00 |
---|---|
Iyear | 2024 |
Report Number | 20240266 |
Supplemental Number | 40220 |
Report Type | Original Final |
Operator Id | 4906 PHMSA Enforcement |
Name | Exxonmobil Pipeline Company Llc |
Operator Street Address | 22777 Springwoods Village Parkway E2.2b-Emp |
Operator City Name | Spring |
Operator State Abbreviation | TX |
Operator Postal Code | 77389 |
Time Zone | Central |
Daylight Savings Ind | Yes |
Location Latitude | 29.974028 Google Maps OpenStreetMap |
Location Longitude | -94.0568452 Google Maps OpenStreetMap |
Commodity Released Type | Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions |
Commodity Subtype | Gasoline (Non-Ethanol) |
Unintentional Release Bbls | 0.17 |
Recovered Bbls | 0.17 |
Fatality Ind | No |
Fatal | 0 |
Injury Ind | No |
Injure | 0 |
Accident Identifier | Local Operating Personnel, Including Contractors |
Operator Type | Operator Employee |
System Part Involved | Onshore Breakout Tank Or Storage Vessel, Including Attached Appurtenances |
On Off Shore | Onshore |
Status When Identified | Normal Operation, Includes Pauses Between Batches And During Maintenance |
Shutdown Due Accident Ind | No |
Shutdown Explain | Drained And Isolated Impacted Tank. Facility Maintained Normal Run Status. |
Communication State Fed Ind | No |
Nrc Rpt Num | Nrc Notification Not Required NRC Report How to search |
Ignite Ind | No |
Notify Qualified Indiv Ind | Yes |
Oil Spill Removal Org Ind | No |
Num Pub Evacuated | 0 |
Pipe Fac Name | Hebert Tank Farm |
Segment Name | Tank 3008, Valve 8 |
Onshore State Abbreviation | Tx |
Onshore Postal Code | 77705 |
Onshore City Name | Beaumont |
Onshore County Name | Jefferson |
Designated Location | Survey Station No. |
Designated Name | Tk 3008, 0+00 |
Federal | No |
Location Type | Totally Contained On Operator-Controlled Property |
Incident Area Type | Tank, Including Attached Appurtenances |
Crossing | No |
Pipe Facility Type | Interstate |
Item Involved | Tank/vessel |
Tank Vessel Subtype | Appurtenance |
Tank Type | Atmospheric |
Safe Fill Level | 35.1 |
Safe Fill Level Exceeded Ind | No |
Api Std Out Of Service Year | 2019 |
Api Std In Service Year | 2023 |
Installation Year | 2019 |
Manufactured Year | Unknown |
Material Involved | Material Other Than Carbon Steel |
Material Details | Flexitallic Stainless Steel Gasket |
Release Type | Leak |
Leak Type | Connection Failure |
Wildlife Impact Ind | No |
Soil Contamination | Yes |
Long Term Assessment | No |
Remediation Ind | No |
Water Contam Ind | No |
Could Be Hca | No |
Commodity Reached Hca | No |
Est Cost Oper Paid | 0 |
Est Cost Gas Released | 15 |
Est Cost Prop Damage | 700 |
Est Cost Emergency | 900 |
Est Cost Environmental | 0 |
Est Cost Other | 0 |
Prpty | 1615 |
Num Persons Hosp Not Ovnght | 0 |
Num Injured Treated By Emt | 0 |
Num Resident Building Affctd | 0 |
Num Business Building Affctd | 0 |
Accident Psig | 8.75 |
Pressure Restriction Ind | No |
Pipeline Function | < 20% Smys Regulated Transmission |
Scada In Place Ind | Yes |
Scada Operating Ind | Yes |
Scada Functional Ind | Yes |
Scada Detection Ind | No |
Scada Conf Ind | No |
Cpm In Place Ind | No |
Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
Investigation Status Details | Leak location and volume not detectable by scada |
Employee Drug Test Ind | No |
Contractor Drug Test Ind | No |
Cause | Equipment Failure |
Cause Details | Non-Threaded Connection Failure |
Eq Failure Type | Non-Threaded Connection Failure |
Other Non Threaded Ind | Gasket |
Additional Defect Ind | Yes |
Preparer Name | K**** B****** |
Preparer Title | Pipeline Safety Advisor |
Preparer Email | K************@e*********.com |
Preparer Telephone | 281-409-2853 |
Prepared Date | 2024-11-13 00:00:00 |
Authorizer Name | L**** B****** |
Authorizer Telephone | 281-382-6003 |
Authorizer Title | Regulatory Compliance Supervisor |
Authorizer Email | L**************@e*********.com |
Narrative | On october 17, 2024, a hebert tank farm operator was performing a daily station check and noticed discoloration around the tank valve on tank 3008 (gasoline service). Employees began hydro excavating below grade for observation. At 8:00 a.M. On october 18, 2024, residual could be seen in the pothole. Samples were pulled for analysis and gasoline was determined to be present. Employees then began draining the tank, which was static at the time of the release, as hydro excavation operations continued in order to determine the origin of the leak. On october 19, 2024, at 5:00 p.M. The release source was determined to be a failed valve gasket. During this event, an estimated 7 gallons (0.17 of a barrel) of gasoline were released. Throughout the event, secondary containment was maintained at the leak location. Dike wall drainage valves were locked in the closed position. The valve gasket was replaced, and the valve was reinstalled. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA