Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2024-10-08 — TX
Operator
Enterprise Products Operating Llc
Cause
Natural Force Damage
Commodity
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$85,000
Incident datetime
2024-10-08 00:00 UTC
Report number
Location
TX
Narrative
On september 12, 2024, at 11:25 central time, a company technician was notified by a railroad inspector inspecting the railroad from hurricane francine of a possible leak from a pipeline. The company employee arrived on site at 11:55 to verify a leak had occurred and notified the houston control center (hcc). Hcc shut remote valves upstream and downstream of the suspected site. The pipeline technician manually closed the upstream valve closer to the leak site at 12:20. Enterprise determined the event to be reportable at 12:45 due to the anticipated repair cost exceeding $50k resulting in immediate notification to nrc at 13:17. Natural force damage occurred from hurricane francine due to lighting possibly impacting an electrical pole resulting in an electrical discharge damaging the pipeline. A type b sleeve was installed repairing the pipeline. The ldenr was notified on 9/12/2024 at 13:31. The louisiana state police notification took place on 9/12/2024 at 12:54. Revised supplemental/final report in part g2 natural force damage sub-cause from other natural force damage to lightning.
Detailed record list
Report Received Date
2024-10-08 00:00:00
Iyear
2024
Report Number
20240236
Supplemental Number
40244
Report Type
Supplemental Final
Operator Id
31618
Name
Enterprise Products Operating Llc
Operator Street Address
1100 Louisiana Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
29.762314
Location Longitude
-91.472499
Commodity Released Type
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype
Other Hvl
Commodity Details
Y-Grade
Unintentional Release Bbls
138
Intentional Release Bbls
25
Recovered Bbls
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Public
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Nrc Rpt Num
1410637
Additional Nrc Report Numbers
1410825
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Type Ind
Manual
Downstream Action Taken
Valve Closure
Downstream Valve Type Ind
Remotely Controlled
Num Pub Evacuated
0
Pipe Fac Name
Promix Main Line
Segment Name
34706
Onshore State Abbreviation
La
Onshore Postal Code
70540
Onshore City Name
Garden City
Onshore County Name
St. Mary
Designated Location
Milepost
Designated Name
2515+76
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
36
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Body
Puddle Weld Ind
No
Pipe Diameter
8
Pipe Wall Thickness
0.25
Pipe Smys
46000
Pipe Specification
Api-5l
Pipe Seam Type
Other
Pipe Seam Details
No Data
Pipe Manufacturer
Unknown
Pipe Coating Type
Coal Tar
Coating Applied Ind
Unknown
Installation Year
1967
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Crack
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
Commercially Nav Ind
Yes
Commercially Nav Yes No
Yes
Usa Ecological Ind
Yes
Usa Ecological Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
3000
Est Cost Prop Damage
85000
Est Cost Emergency
0
Est Cost Environmental
0
Est Cost Other
0
Prpty
88000
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
711
Mop Psig
1440
Mop Cfr Section
Component Design Pressure �195.406(A)(2)
Maop Established Date
1967-05-01 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
89760
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest No Control Room Ind
Yes
Invest No Controller Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Natural Force Damage
Cause Details
Lightning
Natural Force Type
Lightning
Lightning Subtype
Secondary Impact Such As Resulting Nearby Fires
Nf Extreme Weather Ind
Yes
Nf Hurricane Ind
Yes
Preparer Name
N***** G***
Preparer Title
Lead Pipeline Compliance Specialist
Preparer Email
N****@e****.com
Preparer Telephone
985-493-4629
Prepared Date
2024-11-21 00:00:00
Local Contact Name
N***** G***
Local Contact Email
N****@e****.com
Local Contact Telephone
985-493-4629
Authorizer Name
B**** B****
Authorizer Telephone
713-381-2493
Authorizer Title
Transportation Compliance Manager
Authorizer Email
B******@e****.com
Narrative
On september 12, 2024, at 11:25 central time, a company technician was notified by a railroad inspector inspecting the railroad from hurricane francine of a possible leak from a pipeline. The company employee arrived on site at 11:55 to verify a leak had occurred and notified the houston control center (hcc). Hcc shut remote valves upstream and downstream of the suspected site. The pipeline technician manually closed the upstream valve closer to the leak site at 12:20. Enterprise determined the event to be reportable at 12:45 due to the anticipated repair cost exceeding $50k resulting in immediate notification to nrc at 13:17. Natural force damage occurred from hurricane francine due to lighting possibly impacting an electrical pole resulting in an electrical discharge damaging the pipeline. A type b sleeve was installed repairing the pipeline. The ldenr was notified on 9/12/2024 at 13:31. The louisiana state police notification took place on 9/12/2024 at 12:54. Revised supplemental/final report in part g2 natural force damage sub-cause from other natural force damage to lightning.
Report Received Date | 2024-10-08 00:00:00 |
---|---|
Iyear | 2024 |
Report Number | 20240236 |
Supplemental Number | 40244 |
Report Type | Supplemental Final |
Operator Id | 31618 PHMSA Enforcement |
Name | Enterprise Products Operating Llc |
Operator Street Address | 1100 Louisiana Street |
Operator City Name | Houston |
Operator State Abbreviation | TX |
Operator Postal Code | 77002 |
Time Zone | Central |
Daylight Savings Ind | Yes |
Location Latitude | 29.762314 Google Maps OpenStreetMap |
Location Longitude | -91.472499 Google Maps OpenStreetMap |
Commodity Released Type | Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions |
Commodity Subtype | Other Hvl |
Commodity Details | Y-Grade |
Unintentional Release Bbls | 138 |
Intentional Release Bbls | 25 |
Recovered Bbls | 0 |
Fatality Ind | No |
Fatal | 0 |
Injury Ind | No |
Injure | 0 |
Accident Identifier | Notification From Public |
System Part Involved | Onshore Pipeline, Including Valve Sites |
On Off Shore | Onshore |
Status When Identified | Normal Operation, Includes Pauses Between Batches And During Maintenance |
Shutdown Due Accident Ind | Yes |
Communication State Fed Ind | Yes |
Party Initiated Communication | Operator |
Nrc Rpt Num | 1410637 NRC Report How to search |
Additional Nrc Report Numbers | 1410825 |
Ignite Ind | No |
Upstream Action Taken | Valve Closure |
Upstream Valve Type Ind | Manual |
Downstream Action Taken | Valve Closure |
Downstream Valve Type Ind | Remotely Controlled |
Num Pub Evacuated | 0 |
Pipe Fac Name | Promix Main Line |
Segment Name | 34706 |
Onshore State Abbreviation | La |
Onshore Postal Code | 70540 |
Onshore City Name | Garden City |
Onshore County Name | St. Mary |
Designated Location | Milepost |
Designated Name | 2515+76 |
Federal | No |
Location Type | Pipeline Right-Of-Way |
Incident Area Type | Underground |
Incident Area Subtype | Under Soil |
Depth Of Cover | 36 |
Crossing | No |
Pipe Facility Type | Intrastate |
Item Involved | Pipe |
Pipe Type | Pipe Body |
Puddle Weld Ind | No |
Pipe Diameter | 8 |
Pipe Wall Thickness | 0.25 |
Pipe Smys | 46000 |
Pipe Specification | Api-5l |
Pipe Seam Type | Other |
Pipe Seam Details | No Data |
Pipe Manufacturer | Unknown |
Pipe Coating Type | Coal Tar |
Coating Applied Ind | Unknown |
Installation Year | 1967 |
Manufactured Year | Unknown |
Material Involved | Carbon Steel |
Release Type | Leak |
Leak Type | Crack |
Wildlife Impact Ind | No |
Soil Contamination | No |
Long Term Assessment | No |
Remediation Ind | No |
Water Contam Ind | No |
Could Be Hca | Yes |
Commodity Reached Hca | Yes |
Commercially Nav Ind | Yes |
Commercially Nav Yes No | Yes |
Usa Ecological Ind | Yes |
Usa Ecological Yes No | Yes |
Est Cost Oper Paid | 0 |
Est Cost Gas Released | 3000 |
Est Cost Prop Damage | 85000 |
Est Cost Emergency | 0 |
Est Cost Environmental | 0 |
Est Cost Other | 0 |
Prpty | 88000 |
Num Persons Hosp Not Ovnght | 0 |
Num Injured Treated By Emt | 0 |
Num Resident Building Affctd | 0 |
Num Business Building Affctd | 0 |
Accident Psig | 711 |
Mop Psig | 1440 |
Mop Cfr Section | Component Design Pressure �195.406(A)(2) View CFR 49 §192 |
Maop Established Date | 1967-05-01 00:00:00 |
Maop Reversal Flow Ind | No |
Accident Pressure | Pressure Did Not Exceed Mop |
Pressure Restriction Ind | No |
Length Segment Isolated | 89760 |
Internal Inspection Ind | Yes |
Operation Complications Ind | No |
Pipeline Function | > 20% Smys Regulated Transmission |
Scada In Place Ind | Yes |
Scada Operating Ind | Yes |
Scada Functional Ind | Yes |
Scada Detection Ind | No |
Scada Conf Ind | No |
Cpm In Place Ind | Yes |
Cpm Operating Ind | Yes |
Cpm Functional Ind | Yes |
Cpm Detection Ind | No |
Cpm Conf Ind | No |
Investigation Status | Yes, specify investigation result(s): (select all that apply) |
Invest No Control Room Ind | Yes |
Invest No Controller Ind | Yes |
Employee Drug Test Ind | No |
Contractor Drug Test Ind | No |
Cause | Natural Force Damage |
Cause Details | Lightning |
Natural Force Type | Lightning |
Lightning Subtype | Secondary Impact Such As Resulting Nearby Fires |
Nf Extreme Weather Ind | Yes |
Nf Hurricane Ind | Yes |
Preparer Name | N***** G*** |
Preparer Title | Lead Pipeline Compliance Specialist |
Preparer Email | N****@e****.com |
Preparer Telephone | 985-493-4629 |
Prepared Date | 2024-11-21 00:00:00 |
Local Contact Name | N***** G*** |
Local Contact Email | N****@e****.com |
Local Contact Telephone | 985-493-4629 |
Authorizer Name | B**** B**** |
Authorizer Telephone | 713-381-2493 |
Authorizer Title | Transportation Compliance Manager |
Authorizer Email | B******@e****.com |
Narrative | On september 12, 2024, at 11:25 central time, a company technician was notified by a railroad inspector inspecting the railroad from hurricane francine of a possible leak from a pipeline. The company employee arrived on site at 11:55 to verify a leak had occurred and notified the houston control center (hcc). Hcc shut remote valves upstream and downstream of the suspected site. The pipeline technician manually closed the upstream valve closer to the leak site at 12:20. Enterprise determined the event to be reportable at 12:45 due to the anticipated repair cost exceeding $50k resulting in immediate notification to nrc at 13:17. Natural force damage occurred from hurricane francine due to lighting possibly impacting an electrical pole resulting in an electrical discharge damaging the pipeline. A type b sleeve was installed repairing the pipeline. The ldenr was notified on 9/12/2024 at 13:31. The louisiana state police notification took place on 9/12/2024 at 12:54. Revised supplemental/final report in part g2 natural force damage sub-cause from other natural force damage to lightning. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA