HL incident on 2024-06-14 — TX

Operator
Enbridge Energy, Limited Partnership
Cause
Equipment Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$26,411
Incident datetime
2024-06-14 00:00 UTC
Report number
Location
TX
Narrative
On may 17, 2024, at approximately 7:52 pm cdt, an enbridge technician at the walworth station discovered crude oil had misted onto the line 14 unit pump 3 as well as the surrounding equipment and nearby gravel. The technician contacted the edmonton control center, and the unit was isolated. At approximately 8:03 pm cdt the manager on call and the technical supervisor were notified. It was determined at this time that the cleanup and repair costs would exceed the $50,000 nrc reporting threshold. Operations personnel were dispatched to the site for clean-up and remediation. It is estimated that approximately 15 gallons of crude oil was released from a pinhole in the 1/2" stainless steel tubing on the seal flush line of the unit pump. The unit was locked out and isolated until repairs could be made. All impacted gravel has been removed from the release site. The nrc was notified on may 17, 2024, at 8:56 pm cdt (nrc # 1399286). A 48-hour update to the nrc was made on may 19, 2024, at 12:03 pm cdt (nrc# 1399381). The unit motor was sent in for internal cleaning with a third party, tubing was replaced and went back into service on september 12, 2024. The cause of the release was due to abrasive wear in the tubing from solids in the process flow allowing the tubing to thin over time. This caused localized thinning around the 90-degree bend, ending in a small rupture point in the tubing. Due to the excessive wear within the tubing and absence of orifices, thicker wall tubing and orifices will be installed.
Detailed record list
Report Received Date
2024-06-14 00:00:00
Iyear
2024
Report Number
20240144
Supplemental Number
40049
Report Type
Supplemental Final
Operator Id
Name
Enbridge Energy, Limited Partnership
Operator Street Address
915 N Eldridge Parkway, Suite 1100
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77079
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
0.36
Recovered Bbls
0.36
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
No
Shutdown Explain
Unit Was Isolated
Communication State Fed Ind
No
Nrc Rpt Num
Additional Nrc Report Numbers
1399381
Ignite Ind
No
Notify Qualified Indiv Ind
No
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Walworth Station
Segment Name
Line 14 Unit 3 Pump
Onshore State Abbreviation
Wi
Onshore Postal Code
53184
Onshore City Name
Walworth
Onshore County Name
Walworth
Designated Location
Milepost
Designated Name
341.35
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Tubing
Tubing Material
Stainless Steel
Tubing Type
Rigid
Installation Year
2009
Manufactured Year
2009
Material Involved
Material Other Than Carbon Steel
Material Details
Stainless Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
30
Est Cost Prop Damage
26411
Est Cost Emergency
6647
Est Cost Environmental
62890
Est Cost Other
0
Prpty
95978
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
865
Mop Psig
1440
Mop Cfr Section
Component Design Pressure �195.406(A)(2)
Maop Established Date
2007-08-19 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Lack of control center involvement. Release was discovered by field personnel.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Defective Or Loose Tubing Or Fitting
Eq Failure Type
Defective Or Loose Tubing Or Fitting
Additional Erosion Wear Ind
Yes
Preparer Name
S**** S****
Preparer Title
Advisor Regulatory Compliance
Preparer Email
S**********@e*******.com
Preparer Telephone
7153953620
Prepared Date
2024-09-27 00:00:00
Authorizer Name
L*** S**********
Authorizer Telephone
7153941584
Authorizer Title
Supervisor Regulatory Compliance
Authorizer Email
L***************@e*******.com
Narrative
On may 17, 2024, at approximately 7:52 pm cdt, an enbridge technician at the walworth station discovered crude oil had misted onto the line 14 unit pump 3 as well as the surrounding equipment and nearby gravel. The technician contacted the edmonton control center, and the unit was isolated. At approximately 8:03 pm cdt the manager on call and the technical supervisor were notified. It was determined at this time that the cleanup and repair costs would exceed the $50,000 nrc reporting threshold. Operations personnel were dispatched to the site for clean-up and remediation. It is estimated that approximately 15 gallons of crude oil was released from a pinhole in the 1/2" stainless steel tubing on the seal flush line of the unit pump. The unit was locked out and isolated until repairs could be made. All impacted gravel has been removed from the release site. The nrc was notified on may 17, 2024, at 8:56 pm cdt (nrc # 1399286). A 48-hour update to the nrc was made on may 19, 2024, at 12:03 pm cdt (nrc# 1399381). The unit motor was sent in for internal cleaning with a third party, tubing was replaced and went back into service on september 12, 2024. The cause of the release was due to abrasive wear in the tubing from solids in the process flow allowing the tubing to thin over time. This caused localized thinning around the 90-degree bend, ending in a small rupture point in the tubing. Due to the excessive wear within the tubing and absence of orifices, thicker wall tubing and orifices will be installed.
Report Received Date 2024-06-14 00:00:00
Iyear 2024
Report Number 20240144
Supplemental Number 40049
Report Type Supplemental Final
Operator Id 11169 PHMSA Enforcement
Name Enbridge Energy, Limited Partnership
Operator Street Address 915 N Eldridge Parkway, Suite 1100
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77079
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 42.538949 Google Maps OpenStreetMap
Location Longitude -88.634333 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 0.36
Recovered Bbls 0.36
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Operator Employee
System Part Involved Onshore Pump/meter Station Equipment And Piping
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind No
Shutdown Explain Unit Was Isolated
Communication State Fed Ind No
Nrc Rpt Num 1399286 NRC Report How to search
Additional Nrc Report Numbers 1399381
Ignite Ind No
Notify Qualified Indiv Ind No
Oil Spill Removal Org Ind No
Num Pub Evacuated 0
Pipe Fac Name Walworth Station
Segment Name Line 14 Unit 3 Pump
Onshore State Abbreviation Wi
Onshore Postal Code 53184
Onshore City Name Walworth
Onshore County Name Walworth
Designated Location Milepost
Designated Name 341.35
Federal No
Location Type Totally Contained On Operator-Controlled Property
Incident Area Type Aboveground
Incident Area Subtype Typical Aboveground Facility Piping Or Appurtenance
Crossing No
Pipe Facility Type Interstate
Item Involved Tubing
Tubing Material Stainless Steel
Tubing Type Rigid
Installation Year 2009
Manufactured Year 2009
Material Involved Material Other Than Carbon Steel
Material Details Stainless Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca No
Commodity Reached Hca No
Est Cost Oper Paid 0
Est Cost Gas Released 30
Est Cost Prop Damage 26411
Est Cost Emergency 6647
Est Cost Environmental 62890
Est Cost Other 0
Prpty 95978
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 865
Mop Psig 1440
Mop Cfr Section Component Design Pressure �195.406(A)(2) View CFR 49 §192
Maop Established Date 2007-08-19 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind No
Cpm Conf Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details Lack of control center involvement. Release was discovered by field personnel.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Equipment Failure
Cause Details Defective Or Loose Tubing Or Fitting
Eq Failure Type Defective Or Loose Tubing Or Fitting
Additional Erosion Wear Ind Yes
Preparer Name S**** S****
Preparer Title Advisor Regulatory Compliance
Preparer Email S**********@e*******.com
Preparer Telephone 7153953620
Prepared Date 2024-09-27 00:00:00
Authorizer Name L*** S**********
Authorizer Telephone 7153941584
Authorizer Title Supervisor Regulatory Compliance
Authorizer Email L***************@e*******.com
Narrative On may 17, 2024, at approximately 7:52 pm cdt, an enbridge technician at the walworth station discovered crude oil had misted onto the line 14 unit pump 3 as well as the surrounding equipment and nearby gravel. The technician contacted the edmonton control center, and the unit was isolated. At approximately 8:03 pm cdt the manager on call and the technical supervisor were notified. It was determined at this time that the cleanup and repair costs would exceed the $50,000 nrc reporting threshold. Operations personnel were dispatched to the site for clean-up and remediation. It is estimated that approximately 15 gallons of crude oil was released from a pinhole in the 1/2" stainless steel tubing on the seal flush line of the unit pump. The unit was locked out and isolated until repairs could be made. All impacted gravel has been removed from the release site. The nrc was notified on may 17, 2024, at 8:56 pm cdt (nrc # 1399286). A 48-hour update to the nrc was made on may 19, 2024, at 12:03 pm cdt (nrc# 1399381). The unit motor was sent in for internal cleaning with a third party, tubing was replaced and went back into service on september 12, 2024. The cause of the release was due to abrasive wear in the tubing from solids in the process flow allowing the tubing to thin over time. This caused localized thinning around the 90-degree bend, ending in a small rupture point in the tubing. Due to the excessive wear within the tubing and absence of orifices, thicker wall tubing and orifices will be installed.