GTG incident on 2024-06-07 — TX

Operator
Texas Gas Transmission, Llc
Cause
Natural Force Damage
Commodity
Natural Gas
Program
GTG
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$270,000
Incident datetime
2024-06-07 00:00 UTC
Report number
Location
TX
Narrative
On 5/13/2024 at approximately 16:15, texas gas was notified by an evangeline gas employee that texas gas's evangeline delivery meter site had sustained a lightning strike which affected one of the components, resulting in ignition. The highway adjacent to the facility was closed to through traffic on both ends and local emergency services were stationed nearby. Texas gas's operations personnel isolated the bastrop-eunice 26" no. 1 (bae 26-1) pipeline up- and down-stream of the meter facility and reduced pressure through blowdowns. Once the pipeline pressure reached 0 psig and the fire burned out, the bae 26-1 isolation valve was closed. Texas gas has installed 2 flanges and temporary piping to restore service to evangeline. A supplemental report will be submitted once permanent repairs are complete. 1/24/2025 update to submit final report. Permanent repairs include new piping and a new meter skid which were complete on 12/11/2024. Part d, question 7b (estimated cost of operator's property damage & repairs) was also updated.
Detailed record list
Report Received Date
2024-06-07 00:00:00
Iyear
2024
Report Number
20240080
Supplemental Number
40437
Report Type
Supplemental Final
Operator Id
Name
Texas Gas Transmission, Llc
Operator Street Address
9 Greenway Plaza Suite 2800
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77046
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Nrc Rpt Num
Additional Nrc Report Numbers
1398998
Commodity Released Type
Natural Gas
Unintentional Release
2106
Intentional Release
0
Accompanying Liquid
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Status When Identified
Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind
Yes
Communication State Fed Ind
Yes
Party Initiated Communication
Local/state/federal Emergency Responder
Ignite Ind
Yes
How Extinguished
Allowed To Burn Out
Gas Consumed By Fire In Mcf
2106
Explode Ind
No
Num Pub Evacuated
0
On Off Shore
Onshore
Onshore State Abbreviation
La
Onshore Postal Code
70554
Onshore City Name
Mamou
Onshore County Name
Evangeline
Designated Location
Milepost
Designated Name
166+104
Pipe Fac Name
Evangeline Gas Meter Site
Segment Name
Bastrop-Eunice 26-Inch No. 1 (Bae 26-1)
Federal
No
Location Type
Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Interstate
System Part Involved
Onshore Regulator/metering Station Equipment And Piping
Item Involved
Meter
Installation Year
1962
Manufactured Year
1962
Material Involved
Carbon Steel
Release Type
Other
Release Type Details
Lightning Strike Caused Fire And The Release Amount Represents Gas Burned By Fire.
Class Location Type
Class 1 Location
Could Be Hca
No
Pir Radius
551
Heat Damage Ind
No
Non Heat Damage Ind
No
Did Occur In Mca Ind
No
Est Cost Oper Paid
0
Est Cost Unintentional Release
3391
Est Cost Intentional Release
0
Est Cost Prop Damage
270000
Est Cost Emergency
6570
Est Cost Other
0
Gas Cost In Mcf
1.61
Prpty
279961
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
1100
Num Business Building Affctd
8
Wildlife Impact Ind
No
Accident Psig
745
Gas Flow In Pipe In Mcf
321
Mop Psig
810
Mop Cfr Section
Mop Cfr Section Details
192.611(A)(1)(I)
Maop Established Date
2001-10-02 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Maop
Pressure Restriction Ind
No
Gas Required Odorized Ind
No
Pipeline Function
Transmission System
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Accident Identifier
Other
Accident Details
Notification From Evangeline Gas Employee
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest No Control Room Ind
Yes
Invest No Controller Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Natural Force Damage
Cause Details
Lightning
Natural Force Type
Lightning
Lightning Subtype
Direct Hit
Nf Extreme Weather Ind
No
Preparer Name
S****** M********
Preparer Title
Compliance Program Leader
Preparer Email
S****************@b**********.com
Preparer Telephone
(270) 903-5764
Authorizer Name
T*** B****
Authorizer Title
Manager Compliance Services
Authorizer Telephone
(270) 314-6547
Authorizer Email
T*********@b**********.com
Narrative
On 5/13/2024 at approximately 16:15, texas gas was notified by an evangeline gas employee that texas gas's evangeline delivery meter site had sustained a lightning strike which affected one of the components, resulting in ignition. The highway adjacent to the facility was closed to through traffic on both ends and local emergency services were stationed nearby. Texas gas's operations personnel isolated the bastrop-eunice 26" no. 1 (bae 26-1) pipeline up- and down-stream of the meter facility and reduced pressure through blowdowns. Once the pipeline pressure reached 0 psig and the fire burned out, the bae 26-1 isolation valve was closed. Texas gas has installed 2 flanges and temporary piping to restore service to evangeline. A supplemental report will be submitted once permanent repairs are complete. 1/24/2025 update to submit final report. Permanent repairs include new piping and a new meter skid which were complete on 12/11/2024. Part d, question 7b (estimated cost of operator's property damage & repairs) was also updated.
Report Received Date 2024-06-07 00:00:00
Iyear 2024
Report Number 20240080
Supplemental Number 40437
Report Type Supplemental Final
Operator Id 19270 PHMSA Enforcement
Name Texas Gas Transmission, Llc
Operator Street Address 9 Greenway Plaza Suite 2800
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77046
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 30.678911 Google Maps OpenStreetMap
Location Longitude -92.449279 Google Maps OpenStreetMap
Nrc Rpt Num 1398843 NRC Report How to search
Additional Nrc Report Numbers 1398998
Commodity Released Type Natural Gas
Unintentional Release 2106
Intentional Release 0
Accompanying Liquid 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Status When Identified Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind Yes
Communication State Fed Ind Yes
Party Initiated Communication Local/state/federal Emergency Responder
Ignite Ind Yes
How Extinguished Allowed To Burn Out
Gas Consumed By Fire In Mcf 2106
Explode Ind No
Num Pub Evacuated 0
On Off Shore Onshore
Onshore State Abbreviation La
Onshore Postal Code 70554
Onshore City Name Mamou
Onshore County Name Evangeline
Designated Location Milepost
Designated Name 166+104
Pipe Fac Name Evangeline Gas Meter Site
Segment Name Bastrop-Eunice 26-Inch No. 1 (Bae 26-1)
Federal No
Location Type Operator-Controlled Property
Incident Area Type Aboveground
Incident Area Subtype Typical Aboveground Facility Piping Or Appurtenance
Crossing No
Pipe Facility Type Interstate
System Part Involved Onshore Regulator/metering Station Equipment And Piping
Item Involved Meter
Installation Year 1962
Manufactured Year 1962
Material Involved Carbon Steel
Release Type Other
Release Type Details Lightning Strike Caused Fire And The Release Amount Represents Gas Burned By Fire.
Class Location Type Class 1 Location
Could Be Hca No
Pir Radius 551
Heat Damage Ind No
Non Heat Damage Ind No
Did Occur In Mca Ind No
Est Cost Oper Paid 0
Est Cost Unintentional Release 3391
Est Cost Intentional Release 0
Est Cost Prop Damage 270000
Est Cost Emergency 6570
Est Cost Other 0
Gas Cost In Mcf 1.61
Prpty 279961
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 1100
Num Business Building Affctd 8
Wildlife Impact Ind No
Accident Psig 745
Gas Flow In Pipe In Mcf 321
Mop Psig 810
Mop Cfr Section Other View CFR 49 §192
Mop Cfr Section Details 192.611(A)(1)(I)
Maop Established Date 2001-10-02 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Maop
Pressure Restriction Ind No
Gas Required Odorized Ind No
Pipeline Function Transmission System
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Accident Identifier Other
Accident Details Notification From Evangeline Gas Employee
Investigation Status Yes, specify investigation result(s): (select all that apply)
Invest No Control Room Ind Yes
Invest No Controller Ind Yes
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Natural Force Damage
Cause Details Lightning
Natural Force Type Lightning
Lightning Subtype Direct Hit
Nf Extreme Weather Ind No
Preparer Name S****** M********
Preparer Title Compliance Program Leader
Preparer Email S****************@b**********.com
Preparer Telephone (270) 903-5764
Authorizer Name T*** B****
Authorizer Title Manager Compliance Services
Authorizer Telephone (270) 314-6547
Authorizer Email T*********@b**********.com
Narrative On 5/13/2024 at approximately 16:15, texas gas was notified by an evangeline gas employee that texas gas's evangeline delivery meter site had sustained a lightning strike which affected one of the components, resulting in ignition. The highway adjacent to the facility was closed to through traffic on both ends and local emergency services were stationed nearby. Texas gas's operations personnel isolated the bastrop-eunice 26" no. 1 (bae 26-1) pipeline up- and down-stream of the meter facility and reduced pressure through blowdowns. Once the pipeline pressure reached 0 psig and the fire burned out, the bae 26-1 isolation valve was closed. Texas gas has installed 2 flanges and temporary piping to restore service to evangeline. A supplemental report will be submitted once permanent repairs are complete. 1/24/2025 update to submit final report. Permanent repairs include new piping and a new meter skid which were complete on 12/11/2024. Part d, question 7b (estimated cost of operator's property damage & repairs) was also updated.

All rights reserved. Copyright © by ClearPHMSA