Incident details
Operator, cause, commodity and consequences with raw source fields.
GD incident on 2024-11-14 — VA
Operator
Washington Gas Light Co
Cause
Excavation Issue
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$542
Incident datetime
2024-11-14 00:00 UTC
Report number
Location
VA, PRINCE WILLIAM
Narrative
On october 15, 2024, at approximately 1617, blankenship utilities, a contractor directionally drilling a water line, struck a 2" main located at 5992 colby hunt court, haymarket virginia. Washington gas was notified at 1632 via fireboard of the third party damage. The resulting damage, which was a mechanical puncture of the main, caused a gas leak. The first washington gas crew arrived at 1714. Subsequently, gas migrated into the house located at 5992 colby hunt court, found an unknown ignition source, and at approximately 1736 an explosion occurred at 5992 colby hunt court. Washington gas stopped the flow of gas by squeezing off the main at 1847, creating an outage of 8 customers. Crews have restored gas service to the area. There were no injuries from this incident.
Detailed record list
Report Received Date
2024-11-14 00:00:00
Iyear
2024.0
Report Number
20240058.0
Supplemental Number
40217.0
Report Type
Original Final
Operator Id
22182
Name
Washington Gas Light Co
Operator Street Address
1000 Maine Avenue, Sw
Operator City Name
Washington
Operator State Abbreviation
DC
Operator Postal Code
20024.0
Time Zone
Eastern
Daylight Savings Ind
Yes
Location Street Address
5992 Colby Hunt Court
Location City Name
Haymarket
Location County Name
Prince William
Location State Abbreviation
VA
Location Postal Code
20169.0
Location Latitude
38.8284
Location Longitude
-77.62413
Flow Cont Squeeze Off Ind
Yes
Nrc Rpt Num
1413814.0
Additional Nrc Report Numbers
1413954.0
Commodity Released Type
Natural Gas
Unintentional Release
84.25
Intentional Release
0.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
Yes
How Extinguished
Local/state/federal Emergency Responder
Gas Consumed By Fire In Mcf
84.25
Explode Ind
Yes
Num Pub Evacuated
20.0
Federal
No
Location Type
Private Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
46.0
Other Underground Facilities
Yes
Crossing
No
Pipe Facility Type
Privately Owned
System Part Involved
Main
Installation Year
2000.0
Pipe Diameter
2.0
Pipe Specification
Astm D2513
Pipe Manufacturer
Unknown
Material Involved
Plastic
Plastic Type
Polyethylene (Pe)
Plastic Sdr
11
Material Pe Pipe Code
2406
Release Type
Mechanical Puncture
Puncture Axial
0.4
Puncture Circum
2.2
Class Location Type
Class 3 Location
Est Cost Oper Paid
800000.0
Est Cost Prop Damage
542.0
Est Cost Emergency
12092.0
Est Cost Other
0.0
Gas Cost In Mcf
3.24
Est Cost Unintentional Release
273.0
Est Cost Intentional Release
0.0
Prpty
812907.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
8.0
Num Persons Hosp Not Ovnght
0.0
Num Injured Treated By Emt
0.0
Num Resident Building Affctd
8.0
Num Business Building Affctd
0.0
Accident Psig
55.0
Normal Psig
55.0
Mop Psig
60.0
Mop Cfr Section
192.619(A)(1)
Maop Established Date
2000-06-01 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
Injection Pump
Gas Odorized Level
0.6
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Mechanical damage due to third party directional drill.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
Yes
One Call System Ind
Yes
State Law Exempt Ind
No
Notify Cga Dirt
No
Private Row Ind
Yes
Private Subtype
Private Landowner
Joint Trench Ind
No
Cross Bore Ind
No
Depth Of Grade
> 36�
Excavator Type
Contractor
Excavator Equipment
Directional Drilling
Work Performed
Water
One Call Notified Ind
Yes
White Lined Ind
Unknown
Locator Type
Contract Locator
Visible Marks
Yes
Service Interruption
Yes
Service Interruption Hours
25.0
Root Cause Category
Excavation Issue
Root Cause Type
Improper Excavation Practice Not Listed Above
Preparer Name
M*** A****
Preparer Title
Supervisor
Preparer Email
M*********@w******.com
Preparer Telephone
5714054623
Authorizer Name
S***** F***
Authorizer Title
Vp Ehs- Utilities
Authorizer Telephone
5716517504
Authorizer Email
S**********@w******.com
Narrative
On october 15, 2024, at approximately 1617, blankenship utilities, a contractor directionally drilling a water line, struck a 2" main located at 5992 colby hunt court, haymarket virginia. Washington gas was notified at 1632 via fireboard of the third party damage. The resulting damage, which was a mechanical puncture of the main, caused a gas leak. The first washington gas crew arrived at 1714. Subsequently, gas migrated into the house located at 5992 colby hunt court, found an unknown ignition source, and at approximately 1736 an explosion occurred at 5992 colby hunt court. Washington gas stopped the flow of gas by squeezing off the main at 1847, creating an outage of 8 customers. Crews have restored gas service to the area. There were no injuries from this incident.
Report Received Date | 2024-11-14 00:00:00 |
---|---|
Iyear | 2024.0 |
Report Number | 20240058.0 |
Supplemental Number | 40217.0 |
Report Type | Original Final |
Operator Id | 22182 PHMSA Enforcement |
Name | Washington Gas Light Co |
Operator Street Address | 1000 Maine Avenue, Sw |
Operator City Name | Washington |
Operator State Abbreviation | DC |
Operator Postal Code | 20024.0 |
Time Zone | Eastern |
Daylight Savings Ind | Yes |
Location Street Address | 5992 Colby Hunt Court |
Location City Name | Haymarket |
Location County Name | Prince William |
Location State Abbreviation | VA |
Location Postal Code | 20169.0 |
Location Latitude | 38.8284 Google Maps OpenStreetMap |
Location Longitude | -77.62413 Google Maps OpenStreetMap |
Flow Cont Squeeze Off Ind | Yes |
Nrc Rpt Num | 1413814.0 NRC Report How to search |
Additional Nrc Report Numbers | 1413954.0 |
Commodity Released Type | Natural Gas |
Unintentional Release | 84.25 |
Intentional Release | 0.0 |
Fatality Ind | No |
Fatal | 0 |
Injury Ind | No |
Injure | 0 |
Ignite Ind | Yes |
How Extinguished | Local/state/federal Emergency Responder |
Gas Consumed By Fire In Mcf | 84.25 |
Explode Ind | Yes |
Num Pub Evacuated | 20.0 |
Federal | No |
Location Type | Private Property |
Incident Area Type | Underground |
Incident Area Subtype | Under Soil |
Depth Of Cover | 46.0 |
Other Underground Facilities | Yes |
Crossing | No |
Pipe Facility Type | Privately Owned |
System Part Involved | Main |
Installation Year | 2000.0 |
Pipe Diameter | 2.0 |
Pipe Specification | Astm D2513 |
Pipe Manufacturer | Unknown |
Material Involved | Plastic |
Plastic Type | Polyethylene (Pe) |
Plastic Sdr | 11 |
Material Pe Pipe Code | 2406 |
Release Type | Mechanical Puncture |
Puncture Axial | 0.4 |
Puncture Circum | 2.2 |
Class Location Type | Class 3 Location |
Est Cost Oper Paid | 800000.0 |
Est Cost Prop Damage | 542.0 |
Est Cost Emergency | 12092.0 |
Est Cost Other | 0.0 |
Gas Cost In Mcf | 3.24 |
Est Cost Unintentional Release | 273.0 |
Est Cost Intentional Release | 0.0 |
Prpty | 812907.0 |
Commercial Affected | 0.0 |
Industrial Affected | 0.0 |
Residences Affected | 8.0 |
Num Persons Hosp Not Ovnght | 0.0 |
Num Injured Treated By Emt | 0.0 |
Num Resident Building Affctd | 8.0 |
Num Business Building Affctd | 0.0 |
Accident Psig | 55.0 |
Normal Psig | 55.0 |
Mop Psig | 60.0 |
Mop Cfr Section | 192.619(A)(1) View CFR 49 §192 |
Maop Established Date | 2000-06-01 00:00:00 |
Accident Pressure | Pressure Did Not Exceed Maop |
Gas Odorized System Type | Injection Pump |
Gas Odorized Level | 0.6 |
Scada In Place Ind | Yes |
Scada Operating Ind | Yes |
Scada Functional Ind | Yes |
Scada Detection Ind | No |
Scada Conf Ind | No |
Accident Identifier | Notification From Emergency Responder |
Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
Investigation Status Details | Mechanical damage due to third party directional drill. |
Employee Drug Test Ind | No |
Contractor Drug Test Ind | No |
Cause | Excavation Damage |
Cause Details | Excavation Damage By Third Party |
Ex Party Type | Excavation Damage By Third Party |
Prior Notification Ind | Yes |
One Call System Ind | Yes |
State Law Exempt Ind | No |
Notify Cga Dirt | No |
Private Row Ind | Yes |
Private Subtype | Private Landowner |
Joint Trench Ind | No |
Cross Bore Ind | No |
Depth Of Grade | > 36� |
Excavator Type | Contractor |
Excavator Equipment | Directional Drilling |
Work Performed | Water |
One Call Notified Ind | Yes |
White Lined Ind | Unknown |
Locator Type | Contract Locator |
Visible Marks | Yes |
Service Interruption | Yes |
Service Interruption Hours | 25.0 |
Root Cause Category | Excavation Issue |
Root Cause Type | Improper Excavation Practice Not Listed Above |
Preparer Name | M*** A**** |
Preparer Title | Supervisor |
Preparer Email | M*********@w******.com |
Preparer Telephone | 5714054623 |
Authorizer Name | S***** F*** |
Authorizer Title | Vp Ehs- Utilities |
Authorizer Telephone | 5716517504 |
Authorizer Email | S**********@w******.com |
Narrative | On october 15, 2024, at approximately 1617, blankenship utilities, a contractor directionally drilling a water line, struck a 2" main located at 5992 colby hunt court, haymarket virginia. Washington gas was notified at 1632 via fireboard of the third party damage. The resulting damage, which was a mechanical puncture of the main, caused a gas leak. The first washington gas crew arrived at 1714. Subsequently, gas migrated into the house located at 5992 colby hunt court, found an unknown ignition source, and at approximately 1736 an explosion occurred at 5992 colby hunt court. Washington gas stopped the flow of gas by squeezing off the main at 1847, creating an outage of 8 customers. Crews have restored gas service to the area. There were no injuries from this incident. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA