GD incident on 2024-09-30 — NY

Operator
Orange & Rockland Utility Inc
Cause
Excavation Issue
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$5,000
Incident datetime
2024-09-30 00:00 UTC
Report number
Location
NY, ROCKLAND
Narrative
On september 3, 2024, at 1549 hrs., orange and rockland's (o&r) gas emergency response center (gerc) received a report of a possible damage to a natural gas line and a structure fire at 282 avalon gardens drive, located in nanuet, new york, an eight-condominium building. At 1549 hrs., the gerc began dispatching multiple o&r gas crews to the location. At 1547 hrs., to mitigate potential ignition sources, o&r electric crews de-energized electric service to 1,515 customers. At 1559 hrs., o&r gas crews began to arrive at the scene of an active building fire at 282 avalon gardens drive (building #28) and began to assess the situation. Upon confirmation a gas service had been damaged, at 1647 hrs. O&r gas crews closed two curb valves to 282 avalon gardens drive (building #28) and, as a precaution, the adjacent building #25, isolating the two gas services thereby interrupting gas service to a total of 16 gas meters. O&r's initial investigation determined bortech company inc., a contractor hired by verizon, hired e&j pro communication llc (e&j) to install a fiber optic cable conduit. E&j was using a pneumatic trenchless tool known as a "bullet" (the bullet), which damaged a 3/4 inch plastic gas service to 282 avalon gardens drive. The 3/4-inch plastic gas service to 282 avalon gardens drive (building 28) was located and marked correctly. The e&j employee admitted that e&j did not expose the gas or electric by hand to verify the marked location prior to the use of the bullet in both directions. The bullet was shot within the tolerance zone of the gas service as well as the gas main and electric primary. This is a direct violation of nys code rule 753-3.6 - verification of underground facilities. Additionally e&j are in violation of nys code rule 753-3.10 - requirements concerning contact and damage to underground facilities. E&j, while operating the bullet below grade, struck a high-pressure plastic gas service line operating at approximately 55 (psig). E&j removed the bullet and realized the bullet had struck the service. The e&j employee that was operating the bullet stated within 1-2 minutes the escaping gas from the service ignited. The fire severely damaged all eight condominium units in building #28. There were no fatalities and no injuries. At approximately 2000 hrs., o&r crews cut and capped the remaining one gas services (eight gas meters) to the fire damaged building (#28) and at approximately 2130 hrs. O&r gas crews, as a precaution, completed a pressure test for 282 avalon gardens drive ruling out any pre-existing leaks. By 2200 hrs., o&r gas crews restored the eight gas meters (one gas service) to building #25 and by 2208 hrs., o&r had restored electric service to all customers (1,507), except for the eight damaged units. The following day (9/4/2024), o&r gas crews performed a leak survey yielding no leaks found. The fire was investigated by the town of clarkstown (police department arson unit and fire inspection unit) located in new city, new york. Notes: 1. At this time, the estimated cost of public and non-operator private property damage paid/reimbursed by the operator and the estimated other costs is unknown. 2. Re: q21a. Estimated time based upon when 44-control (rockland county emergency dispatch) was notified a gas line was struck and the building was on fire.
Detailed record list
Report Received Date
2024-09-30 00:00:00
Iyear
2024.0
Report Number
20240052.0
Supplemental Number
41203.0
Report Type
Supplemental Final
Operator Id
Name
Orange & Rockland Utility Inc
Operator Street Address
One Blue Hill Plaza
Operator City Name
Pearl River
Operator State Abbreviation
NY
Operator Postal Code
10965.0
Time Zone
Eastern
Daylight Savings Ind
Yes
Location Street Address
282 Avalon Garden
Location City Name
Nanuet
Location County Name
Rockland
Location State Abbreviation
NY
Location Postal Code
10954.0
Location Latitude
Location Longitude
Flow Cont Service Valve Ind
Yes
Nrc Rpt Num
Additional Nrc Report Numbers
1410018.0
Commodity Released Type
Natural Gas
Unintentional Release
18.5
Intentional Release
0.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
Yes
How Extinguished
Local/state/federal Emergency Responder
Gas Consumed By Fire In Mcf
14
Explode Ind
No
Num Pub Evacuated
2.0
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Federal
No
Location Type
Private Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
24.0
Other Underground Facilities
No
Crossing
No
Pipe Facility Type
Investor Owned
System Part Involved
Service
Installation Year
1998.0
Customer Type
Multi-Family Residential
Was Efv Installed Before Ind
No
Curb Valve Inst Before Inc Ind
Yes
Pipe Diameter
0.75
Pipe Specification
Astm D2513
Pipe Manufacturer
Plexco
Material Involved
Plastic
Plastic Type
Polyethylene (Pe)
Plastic Sdr
11
Material Pe Pipe Code
4710
Release Type
Mechanical Puncture
Puncture Axial
1.2
Puncture Circum
0.2
Class Location Type
Class 3 Location
Est Cost Oper Paid
0.0
Est Cost Prop Damage
5000.0
Est Cost Emergency
35000.0
Est Cost Other
0.0
Est Cost Other Details
Estimated Other Costs Are Unknown
Gas Cost In Mcf
1.68
Est Cost Unintentional Release
31.0
Est Cost Intentional Release
0.0
Prpty
40031.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
16.0
Num Persons Hosp Not Ovnght
0.0
Num Injured Treated By Emt
0.0
Num Resident Building Affctd
2.0
Num Business Building Affctd
0.0
Accident Psig
55.0
Normal Psig
55.0
Mop Psig
80.0
Mop Cfr Section
192.619(A)(2)
Maop Established Date
1998-04-09 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
Combination Of Odorization Types
Gas Odorized Lvl Not Msrd Ind
Yes
Scada In Place Ind
No
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
Yes
One Call System Ind
Yes
State Law Exempt Ind
No
Notify Cga Dirt
No
Private Row Ind
Yes
Private Subtype
Private Landowner
Joint Trench Ind
No
Cross Bore Ind
Yes
Depth Of Grade
18� � 36�
Excavator Type
Contractor
Excavator Equipment
Boring
Work Performed
Telecommunications
One Call Notified Ind
Yes
One Call Ticket Num
826400000000.0
One Call Center Name
Udig
White Lined Ind
No
Locator Type
Contract Locator
Visible Marks
Yes
Service Interruption
Yes
Service Interruption Hours
5.0
Root Cause Category
Excavation Issue
Root Cause Type
Excavator Dug Prior To Verifying Marks By Test-Hole (Pothole)
Preparer Name
P****** W****
Preparer Title
Manager
Preparer Email
W*****@o**.com
Preparer Telephone
8455773731
Authorizer Name
P****** W****
Authorizer Title
Manager
Authorizer Telephone
8455773731
Authorizer Email
W*****@o**.com
Narrative
On september 3, 2024, at 1549 hrs., orange and rockland's (o&r) gas emergency response center (gerc) received a report of a possible damage to a natural gas line and a structure fire at 282 avalon gardens drive, located in nanuet, new york, an eight-condominium building. At 1549 hrs., the gerc began dispatching multiple o&r gas crews to the location. At 1547 hrs., to mitigate potential ignition sources, o&r electric crews de-energized electric service to 1,515 customers. At 1559 hrs., o&r gas crews began to arrive at the scene of an active building fire at 282 avalon gardens drive (building #28) and began to assess the situation. Upon confirmation a gas service had been damaged, at 1647 hrs. O&r gas crews closed two curb valves to 282 avalon gardens drive (building #28) and, as a precaution, the adjacent building #25, isolating the two gas services thereby interrupting gas service to a total of 16 gas meters. O&r's initial investigation determined bortech company inc., a contractor hired by verizon, hired e&j pro communication llc (e&j) to install a fiber optic cable conduit. E&j was using a pneumatic trenchless tool known as a "bullet" (the bullet), which damaged a 3/4 inch plastic gas service to 282 avalon gardens drive. The 3/4-inch plastic gas service to 282 avalon gardens drive (building 28) was located and marked correctly. The e&j employee admitted that e&j did not expose the gas or electric by hand to verify the marked location prior to the use of the bullet in both directions. The bullet was shot within the tolerance zone of the gas service as well as the gas main and electric primary. This is a direct violation of nys code rule 753-3.6 - verification of underground facilities. Additionally e&j are in violation of nys code rule 753-3.10 - requirements concerning contact and damage to underground facilities. E&j, while operating the bullet below grade, struck a high-pressure plastic gas service line operating at approximately 55 (psig). E&j removed the bullet and realized the bullet had struck the service. The e&j employee that was operating the bullet stated within 1-2 minutes the escaping gas from the service ignited. The fire severely damaged all eight condominium units in building #28. There were no fatalities and no injuries. At approximately 2000 hrs., o&r crews cut and capped the remaining one gas services (eight gas meters) to the fire damaged building (#28) and at approximately 2130 hrs. O&r gas crews, as a precaution, completed a pressure test for 282 avalon gardens drive ruling out any pre-existing leaks. By 2200 hrs., o&r gas crews restored the eight gas meters (one gas service) to building #25 and by 2208 hrs., o&r had restored electric service to all customers (1,507), except for the eight damaged units. The following day (9/4/2024), o&r gas crews performed a leak survey yielding no leaks found. The fire was investigated by the town of clarkstown (police department arson unit and fire inspection unit) located in new city, new york. Notes: 1. At this time, the estimated cost of public and non-operator private property damage paid/reimbursed by the operator and the estimated other costs is unknown. 2. Re: q21a. Estimated time based upon when 44-control (rockland county emergency dispatch) was notified a gas line was struck and the building was on fire.
Report Received Date 2024-09-30 00:00:00
Iyear 2024.0
Report Number 20240052.0
Supplemental Number 41203.0
Report Type Supplemental Final
Operator Id 14330 PHMSA Enforcement
Name Orange & Rockland Utility Inc
Operator Street Address One Blue Hill Plaza
Operator City Name Pearl River
Operator State Abbreviation NY
Operator Postal Code 10965.0
Time Zone Eastern
Daylight Savings Ind Yes
Location Street Address 282 Avalon Garden
Location City Name Nanuet
Location County Name Rockland
Location State Abbreviation NY
Location Postal Code 10954.0
Location Latitude 41.105986 Google Maps OpenStreetMap
Location Longitude -74.020876 Google Maps OpenStreetMap
Flow Cont Service Valve Ind Yes
Nrc Rpt Num 1409845.0 NRC Report How to search
Additional Nrc Report Numbers 1410018.0
Commodity Released Type Natural Gas
Unintentional Release 18.5
Intentional Release 0.0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Ignite Ind Yes
How Extinguished Local/state/federal Emergency Responder
Gas Consumed By Fire In Mcf 14
Explode Ind No
Num Pub Evacuated 2.0
Communication State Fed Ind Yes
Party Initiated Communication Operator
Federal No
Location Type Private Property
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 24.0
Other Underground Facilities No
Crossing No
Pipe Facility Type Investor Owned
System Part Involved Service
Installation Year 1998.0
Customer Type Multi-Family Residential
Was Efv Installed Before Ind No
Curb Valve Inst Before Inc Ind Yes
Pipe Diameter 0.75
Pipe Specification Astm D2513
Pipe Manufacturer Plexco
Material Involved Plastic
Plastic Type Polyethylene (Pe)
Plastic Sdr 11
Material Pe Pipe Code 4710
Release Type Mechanical Puncture
Puncture Axial 1.2
Puncture Circum 0.2
Class Location Type Class 3 Location
Est Cost Oper Paid 0.0
Est Cost Prop Damage 5000.0
Est Cost Emergency 35000.0
Est Cost Other 0.0
Est Cost Other Details Estimated Other Costs Are Unknown
Gas Cost In Mcf 1.68
Est Cost Unintentional Release 31.0
Est Cost Intentional Release 0.0
Prpty 40031.0
Commercial Affected 0.0
Industrial Affected 0.0
Residences Affected 16.0
Num Persons Hosp Not Ovnght 0.0
Num Injured Treated By Emt 0.0
Num Resident Building Affctd 2.0
Num Business Building Affctd 0.0
Accident Psig 55.0
Normal Psig 55.0
Mop Psig 80.0
Mop Cfr Section 192.619(A)(2) View CFR 49 §192
Maop Established Date 1998-04-09 00:00:00
Accident Pressure Pressure Did Not Exceed Maop
Gas Odorized System Type Combination Of Odorization Types
Gas Odorized Lvl Not Msrd Ind Yes
Scada In Place Ind No
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Operator Employee
Investigation Status No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Excavation Damage
Cause Details Excavation Damage By Third Party
Ex Party Type Excavation Damage By Third Party
Prior Notification Ind Yes
One Call System Ind Yes
State Law Exempt Ind No
Notify Cga Dirt No
Private Row Ind Yes
Private Subtype Private Landowner
Joint Trench Ind No
Cross Bore Ind Yes
Depth Of Grade 18� � 36�
Excavator Type Contractor
Excavator Equipment Boring
Work Performed Telecommunications
One Call Notified Ind Yes
One Call Ticket Num 826400000000.0
One Call Center Name Udig
White Lined Ind No
Locator Type Contract Locator
Visible Marks Yes
Service Interruption Yes
Service Interruption Hours 5.0
Root Cause Category Excavation Issue
Root Cause Type Excavator Dug Prior To Verifying Marks By Test-Hole (Pothole)
Preparer Name P****** W****
Preparer Title Manager
Preparer Email W*****@o**.com
Preparer Telephone 8455773731
Authorizer Name P****** W****
Authorizer Title Manager
Authorizer Telephone 8455773731
Authorizer Email W*****@o**.com
Narrative On september 3, 2024, at 1549 hrs., orange and rockland's (o&r) gas emergency response center (gerc) received a report of a possible damage to a natural gas line and a structure fire at 282 avalon gardens drive, located in nanuet, new york, an eight-condominium building. At 1549 hrs., the gerc began dispatching multiple o&r gas crews to the location. At 1547 hrs., to mitigate potential ignition sources, o&r electric crews de-energized electric service to 1,515 customers. At 1559 hrs., o&r gas crews began to arrive at the scene of an active building fire at 282 avalon gardens drive (building #28) and began to assess the situation. Upon confirmation a gas service had been damaged, at 1647 hrs. O&r gas crews closed two curb valves to 282 avalon gardens drive (building #28) and, as a precaution, the adjacent building #25, isolating the two gas services thereby interrupting gas service to a total of 16 gas meters. O&r's initial investigation determined bortech company inc., a contractor hired by verizon, hired e&j pro communication llc (e&j) to install a fiber optic cable conduit. E&j was using a pneumatic trenchless tool known as a "bullet" (the bullet), which damaged a 3/4 inch plastic gas service to 282 avalon gardens drive. The 3/4-inch plastic gas service to 282 avalon gardens drive (building 28) was located and marked correctly. The e&j employee admitted that e&j did not expose the gas or electric by hand to verify the marked location prior to the use of the bullet in both directions. The bullet was shot within the tolerance zone of the gas service as well as the gas main and electric primary. This is a direct violation of nys code rule 753-3.6 - verification of underground facilities. Additionally e&j are in violation of nys code rule 753-3.10 - requirements concerning contact and damage to underground facilities. E&j, while operating the bullet below grade, struck a high-pressure plastic gas service line operating at approximately 55 (psig). E&j removed the bullet and realized the bullet had struck the service. The e&j employee that was operating the bullet stated within 1-2 minutes the escaping gas from the service ignited. The fire severely damaged all eight condominium units in building #28. There were no fatalities and no injuries. At approximately 2000 hrs., o&r crews cut and capped the remaining one gas services (eight gas meters) to the fire damaged building (#28) and at approximately 2130 hrs. O&r gas crews, as a precaution, completed a pressure test for 282 avalon gardens drive ruling out any pre-existing leaks. By 2200 hrs., o&r gas crews restored the eight gas meters (one gas service) to building #25 and by 2208 hrs., o&r had restored electric service to all customers (1,507), except for the eight damaged units. The following day (9/4/2024), o&r gas crews performed a leak survey yielding no leaks found. The fire was investigated by the town of clarkstown (police department arson unit and fire inspection unit) located in new city, new york. Notes: 1. At this time, the estimated cost of public and non-operator private property damage paid/reimbursed by the operator and the estimated other costs is unknown. 2. Re: q21a. Estimated time based upon when 44-control (rockland county emergency dispatch) was notified a gas line was struck and the building was on fire.