Incident details
Operator, cause, commodity and consequences with raw source fields.
GD incident on 2024-08-01 — TX
Operator
Centerpoint Energy Resources Corporation
Cause
Excavation Issue
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$113
Incident datetime
2024-08-01 00:00 UTC
Report number
Location
TX, HARRIS
Narrative
On july 2, 2024, ram jack foundation solutions were performing foundation repairs at 15602 four seasons. While excavating with hand tools, the properly marked gas service line at this location was struck. The escaping gas ignited, resulting in fire damage to the single-story structure. The fire department responded and notified centerpoint energy at 11:45am. Service technician arrived at 12:11pm, gas was shut off at 1:45pm, line was squeezed off at the service tap location by the fire department on site and centerpoint energy personnel. Additionally, this same service line was struck on july 1, 2024, by the same 3rd party excavator, ram jack foundation solutions. Centerpoint energy responded and made repairs on july 1,2024.
Detailed record list
Report Received Date
2024-08-01 00:00:00
Iyear
2024.0
Report Number
20240040.0
Supplemental Number
39849.0
Report Type
Original Final
Operator Id
4499
Name
Centerpoint Energy Resources Corporation
Operator Street Address
1111 Louisiana St
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002.0
Time Zone
Central
Daylight Savings Ind
Yes
Location Street Address
15602 Four Season Dr
Location City Name
Houston
Location County Name
Harris
Location State Abbreviation
TX
Location Postal Code
77084.0
Location Latitude
29.8519656
Location Longitude
-95.6308084
Flow Cont Squeeze Off Ind
Yes
Nrc Rpt Num
1403630.0
Additional Nrc Report Numbers
1403858.0
Commodity Released Type
Natural Gas
Unintentional Release
11.75
Intentional Release
0.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
Yes
How Extinguished
Local/state/federal Emergency Responder
Gas Consumed By Fire In Mcf
11.75
Explode Ind
No
Num Pub Evacuated
0.0
Federal
No
Location Type
Private Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
18.0
Other Underground Facilities
No
Crossing
No
Pipe Facility Type
Investor Owned
System Part Involved
Service
Installation Year
1983.0
Manufactured Year
1983.0
Customer Type
Single Family Residential
Was Efv Installed Before Ind
No
Curb Valve Inst Before Inc Ind
No
Pipe Diameter
0.5
Pipe Specification
Mdpe 2306
Pipe Manufacturer
Dupont
Material Involved
Plastic
Plastic Type
Other
Plastic Details
Aldyl A
Plastic Sdr
11
Release Type
Rupture
Rupture Orient
Longitudinal
Rupture Length
0.5
Rupture Width
0.5
Class Location Type
Class 3 Location
Est Cost Oper Paid
200000.0
Est Cost Prop Damage
113.0
Est Cost Emergency
3247.0
Est Cost Other
0.0
Gas Cost In Mcf
5.99
Est Cost Unintentional Release
70.0
Est Cost Intentional Release
0.0
Prpty
203430.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
1.0
Num Persons Hosp Not Ovnght
0.0
Num Injured Treated By Emt
0.0
Num Resident Building Affctd
1.0
Num Business Building Affctd
0.0
Accident Psig
45.0
Normal Psig
45.0
Mop Psig
60.0
Mop Cfr Section
192.619(A)(1)
Maop Established Date
1983-12-02 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
Injection Pump
Gas Odorized Level
0.4
Scada In Place Ind
No
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Pressure did not exceed detection threshold of the system.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
Yes
One Call System Ind
Yes
Excavator Ind
Yes
Contractor Ind
Yes
State Law Exempt Ind
No
Notify Cga Dirt
Yes
Private Row Ind
Yes
Private Subtype
Private Landowner
Joint Trench Ind
No
Cross Bore Ind
No
Depth Of Grade
< 18�
Excavator Type
Contractor
Excavator Equipment
Hand Tools
Work Performed
Unknown/other
One Call Notified Ind
Yes
One Call Ticket Num
246768597.0
One Call Center Name
811
White Lined Ind
No
Locator Type
Contract Locator
Visible Marks
Yes
Service Interruption
No
Root Cause Category
Excavation Issue
Root Cause Type
Excavator Failed To Maintain Clearance After Verifying Marks
Preparer Name
E**** S******
Preparer Title
Operations Specialist
Preparer Email
E************@c****************.com
Preparer Telephone
281-755-2470
Local Contact Name
E**** S******
Local Contact Email
E************@c****************.com
Local Contact Telephone
281-755-2470
Authorizer Name
P****** G****
Authorizer Title
Manager Gas Compliance South
Authorizer Telephone
713-378-9845
Authorizer Email
P************@c****************.com
Narrative
On july 2, 2024, ram jack foundation solutions were performing foundation repairs at 15602 four seasons. While excavating with hand tools, the properly marked gas service line at this location was struck. The escaping gas ignited, resulting in fire damage to the single-story structure. The fire department responded and notified centerpoint energy at 11:45am. Service technician arrived at 12:11pm, gas was shut off at 1:45pm, line was squeezed off at the service tap location by the fire department on site and centerpoint energy personnel. Additionally, this same service line was struck on july 1, 2024, by the same 3rd party excavator, ram jack foundation solutions. Centerpoint energy responded and made repairs on july 1,2024.
Report Received Date | 2024-08-01 00:00:00 |
---|---|
Iyear | 2024.0 |
Report Number | 20240040.0 |
Supplemental Number | 39849.0 |
Report Type | Original Final |
Operator Id | 4499 PHMSA Enforcement |
Name | Centerpoint Energy Resources Corporation |
Operator Street Address | 1111 Louisiana St |
Operator City Name | Houston |
Operator State Abbreviation | TX |
Operator Postal Code | 77002.0 |
Time Zone | Central |
Daylight Savings Ind | Yes |
Location Street Address | 15602 Four Season Dr |
Location City Name | Houston |
Location County Name | Harris |
Location State Abbreviation | TX |
Location Postal Code | 77084.0 |
Location Latitude | 29.8519656 Google Maps OpenStreetMap |
Location Longitude | -95.6308084 Google Maps OpenStreetMap |
Flow Cont Squeeze Off Ind | Yes |
Nrc Rpt Num | 1403630.0 NRC Report How to search |
Additional Nrc Report Numbers | 1403858.0 |
Commodity Released Type | Natural Gas |
Unintentional Release | 11.75 |
Intentional Release | 0.0 |
Fatality Ind | No |
Fatal | 0 |
Injury Ind | No |
Injure | 0 |
Ignite Ind | Yes |
How Extinguished | Local/state/federal Emergency Responder |
Gas Consumed By Fire In Mcf | 11.75 |
Explode Ind | No |
Num Pub Evacuated | 0.0 |
Federal | No |
Location Type | Private Property |
Incident Area Type | Underground |
Incident Area Subtype | Under Soil |
Depth Of Cover | 18.0 |
Other Underground Facilities | No |
Crossing | No |
Pipe Facility Type | Investor Owned |
System Part Involved | Service |
Installation Year | 1983.0 |
Manufactured Year | 1983.0 |
Customer Type | Single Family Residential |
Was Efv Installed Before Ind | No |
Curb Valve Inst Before Inc Ind | No |
Pipe Diameter | 0.5 |
Pipe Specification | Mdpe 2306 |
Pipe Manufacturer | Dupont |
Material Involved | Plastic |
Plastic Type | Other |
Plastic Details | Aldyl A |
Plastic Sdr | 11 |
Release Type | Rupture |
Rupture Orient | Longitudinal |
Rupture Length | 0.5 |
Rupture Width | 0.5 |
Class Location Type | Class 3 Location |
Est Cost Oper Paid | 200000.0 |
Est Cost Prop Damage | 113.0 |
Est Cost Emergency | 3247.0 |
Est Cost Other | 0.0 |
Gas Cost In Mcf | 5.99 |
Est Cost Unintentional Release | 70.0 |
Est Cost Intentional Release | 0.0 |
Prpty | 203430.0 |
Commercial Affected | 0.0 |
Industrial Affected | 0.0 |
Residences Affected | 1.0 |
Num Persons Hosp Not Ovnght | 0.0 |
Num Injured Treated By Emt | 0.0 |
Num Resident Building Affctd | 1.0 |
Num Business Building Affctd | 0.0 |
Accident Psig | 45.0 |
Normal Psig | 45.0 |
Mop Psig | 60.0 |
Mop Cfr Section | 192.619(A)(1) View CFR 49 §192 |
Maop Established Date | 1983-12-02 00:00:00 |
Accident Pressure | Pressure Did Not Exceed Maop |
Gas Odorized System Type | Injection Pump |
Gas Odorized Level | 0.4 |
Scada In Place Ind | No |
Accident Identifier | Notification From Emergency Responder |
Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
Investigation Status Details | Pressure did not exceed detection threshold of the system. |
Employee Drug Test Ind | No |
Contractor Drug Test Ind | No |
Cause | Excavation Damage |
Cause Details | Excavation Damage By Third Party |
Ex Party Type | Excavation Damage By Third Party |
Prior Notification Ind | Yes |
One Call System Ind | Yes |
Excavator Ind | Yes |
Contractor Ind | Yes |
State Law Exempt Ind | No |
Notify Cga Dirt | Yes |
Private Row Ind | Yes |
Private Subtype | Private Landowner |
Joint Trench Ind | No |
Cross Bore Ind | No |
Depth Of Grade | < 18� |
Excavator Type | Contractor |
Excavator Equipment | Hand Tools |
Work Performed | Unknown/other |
One Call Notified Ind | Yes |
One Call Ticket Num | 246768597.0 |
One Call Center Name | 811 |
White Lined Ind | No |
Locator Type | Contract Locator |
Visible Marks | Yes |
Service Interruption | No |
Root Cause Category | Excavation Issue |
Root Cause Type | Excavator Failed To Maintain Clearance After Verifying Marks |
Preparer Name | E**** S****** |
Preparer Title | Operations Specialist |
Preparer Email | E************@c****************.com |
Preparer Telephone | 281-755-2470 |
Local Contact Name | E**** S****** |
Local Contact Email | E************@c****************.com |
Local Contact Telephone | 281-755-2470 |
Authorizer Name | P****** G**** |
Authorizer Title | Manager Gas Compliance South |
Authorizer Telephone | 713-378-9845 |
Authorizer Email | P************@c****************.com |
Narrative | On july 2, 2024, ram jack foundation solutions were performing foundation repairs at 15602 four seasons. While excavating with hand tools, the properly marked gas service line at this location was struck. The escaping gas ignited, resulting in fire damage to the single-story structure. The fire department responded and notified centerpoint energy at 11:45am. Service technician arrived at 12:11pm, gas was shut off at 1:45pm, line was squeezed off at the service tap location by the fire department on site and centerpoint energy personnel. Additionally, this same service line was struck on july 1, 2024, by the same 3rd party excavator, ram jack foundation solutions. Centerpoint energy responded and made repairs on july 1,2024. |