GD incident on 2024-08-01 — TX

Operator
Centerpoint Energy Resources Corporation
Cause
Excavation Issue
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$113
Incident datetime
2024-08-01 00:00 UTC
Report number
Location
TX, HARRIS
Narrative
On july 2, 2024, ram jack foundation solutions were performing foundation repairs at 15602 four seasons. While excavating with hand tools, the properly marked gas service line at this location was struck. The escaping gas ignited, resulting in fire damage to the single-story structure. The fire department responded and notified centerpoint energy at 11:45am. Service technician arrived at 12:11pm, gas was shut off at 1:45pm, line was squeezed off at the service tap location by the fire department on site and centerpoint energy personnel. Additionally, this same service line was struck on july 1, 2024, by the same 3rd party excavator, ram jack foundation solutions. Centerpoint energy responded and made repairs on july 1,2024.
Detailed record list
Report Received Date
2024-08-01 00:00:00
Iyear
2024.0
Report Number
20240040.0
Supplemental Number
39849.0
Report Type
Original Final
Operator Id
Name
Centerpoint Energy Resources Corporation
Operator Street Address
1111 Louisiana St
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002.0
Time Zone
Central
Daylight Savings Ind
Yes
Location Street Address
15602 Four Season Dr
Location City Name
Houston
Location County Name
Harris
Location State Abbreviation
TX
Location Postal Code
77084.0
Location Latitude
Location Longitude
Flow Cont Squeeze Off Ind
Yes
Nrc Rpt Num
Additional Nrc Report Numbers
1403858.0
Commodity Released Type
Natural Gas
Unintentional Release
11.75
Intentional Release
0.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
Yes
How Extinguished
Local/state/federal Emergency Responder
Gas Consumed By Fire In Mcf
11.75
Explode Ind
No
Num Pub Evacuated
0.0
Federal
No
Location Type
Private Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
18.0
Other Underground Facilities
No
Crossing
No
Pipe Facility Type
Investor Owned
System Part Involved
Service
Installation Year
1983.0
Manufactured Year
1983.0
Customer Type
Single Family Residential
Was Efv Installed Before Ind
No
Curb Valve Inst Before Inc Ind
No
Pipe Diameter
0.5
Pipe Specification
Mdpe 2306
Pipe Manufacturer
Dupont
Material Involved
Plastic
Plastic Type
Other
Plastic Details
Aldyl A
Plastic Sdr
11
Release Type
Rupture
Rupture Orient
Longitudinal
Rupture Length
0.5
Rupture Width
0.5
Class Location Type
Class 3 Location
Est Cost Oper Paid
200000.0
Est Cost Prop Damage
113.0
Est Cost Emergency
3247.0
Est Cost Other
0.0
Gas Cost In Mcf
5.99
Est Cost Unintentional Release
70.0
Est Cost Intentional Release
0.0
Prpty
203430.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
1.0
Num Persons Hosp Not Ovnght
0.0
Num Injured Treated By Emt
0.0
Num Resident Building Affctd
1.0
Num Business Building Affctd
0.0
Accident Psig
45.0
Normal Psig
45.0
Mop Psig
60.0
Mop Cfr Section
192.619(A)(1)
Maop Established Date
1983-12-02 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
Injection Pump
Gas Odorized Level
0.4
Scada In Place Ind
No
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Pressure did not exceed detection threshold of the system.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
Yes
One Call System Ind
Yes
Excavator Ind
Yes
Contractor Ind
Yes
State Law Exempt Ind
No
Notify Cga Dirt
Yes
Private Row Ind
Yes
Private Subtype
Private Landowner
Joint Trench Ind
No
Cross Bore Ind
No
Depth Of Grade
< 18�
Excavator Type
Contractor
Excavator Equipment
Hand Tools
Work Performed
Unknown/other
One Call Notified Ind
Yes
One Call Ticket Num
246768597.0
One Call Center Name
811
White Lined Ind
No
Locator Type
Contract Locator
Visible Marks
Yes
Service Interruption
No
Root Cause Category
Excavation Issue
Root Cause Type
Excavator Failed To Maintain Clearance After Verifying Marks
Preparer Name
E**** S******
Preparer Title
Operations Specialist
Preparer Email
E************@c****************.com
Preparer Telephone
281-755-2470
Local Contact Name
E**** S******
Local Contact Email
E************@c****************.com
Local Contact Telephone
281-755-2470
Authorizer Name
P****** G****
Authorizer Title
Manager Gas Compliance South
Authorizer Telephone
713-378-9845
Authorizer Email
P************@c****************.com
Narrative
On july 2, 2024, ram jack foundation solutions were performing foundation repairs at 15602 four seasons. While excavating with hand tools, the properly marked gas service line at this location was struck. The escaping gas ignited, resulting in fire damage to the single-story structure. The fire department responded and notified centerpoint energy at 11:45am. Service technician arrived at 12:11pm, gas was shut off at 1:45pm, line was squeezed off at the service tap location by the fire department on site and centerpoint energy personnel. Additionally, this same service line was struck on july 1, 2024, by the same 3rd party excavator, ram jack foundation solutions. Centerpoint energy responded and made repairs on july 1,2024.
Report Received Date 2024-08-01 00:00:00
Iyear 2024.0
Report Number 20240040.0
Supplemental Number 39849.0
Report Type Original Final
Operator Id 4499 PHMSA Enforcement
Name Centerpoint Energy Resources Corporation
Operator Street Address 1111 Louisiana St
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77002.0
Time Zone Central
Daylight Savings Ind Yes
Location Street Address 15602 Four Season Dr
Location City Name Houston
Location County Name Harris
Location State Abbreviation TX
Location Postal Code 77084.0
Location Latitude 29.8519656 Google Maps OpenStreetMap
Location Longitude -95.6308084 Google Maps OpenStreetMap
Flow Cont Squeeze Off Ind Yes
Nrc Rpt Num 1403630.0 NRC Report How to search
Additional Nrc Report Numbers 1403858.0
Commodity Released Type Natural Gas
Unintentional Release 11.75
Intentional Release 0.0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Ignite Ind Yes
How Extinguished Local/state/federal Emergency Responder
Gas Consumed By Fire In Mcf 11.75
Explode Ind No
Num Pub Evacuated 0.0
Federal No
Location Type Private Property
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 18.0
Other Underground Facilities No
Crossing No
Pipe Facility Type Investor Owned
System Part Involved Service
Installation Year 1983.0
Manufactured Year 1983.0
Customer Type Single Family Residential
Was Efv Installed Before Ind No
Curb Valve Inst Before Inc Ind No
Pipe Diameter 0.5
Pipe Specification Mdpe 2306
Pipe Manufacturer Dupont
Material Involved Plastic
Plastic Type Other
Plastic Details Aldyl A
Plastic Sdr 11
Release Type Rupture
Rupture Orient Longitudinal
Rupture Length 0.5
Rupture Width 0.5
Class Location Type Class 3 Location
Est Cost Oper Paid 200000.0
Est Cost Prop Damage 113.0
Est Cost Emergency 3247.0
Est Cost Other 0.0
Gas Cost In Mcf 5.99
Est Cost Unintentional Release 70.0
Est Cost Intentional Release 0.0
Prpty 203430.0
Commercial Affected 0.0
Industrial Affected 0.0
Residences Affected 1.0
Num Persons Hosp Not Ovnght 0.0
Num Injured Treated By Emt 0.0
Num Resident Building Affctd 1.0
Num Business Building Affctd 0.0
Accident Psig 45.0
Normal Psig 45.0
Mop Psig 60.0
Mop Cfr Section 192.619(A)(1) View CFR 49 §192
Maop Established Date 1983-12-02 00:00:00
Accident Pressure Pressure Did Not Exceed Maop
Gas Odorized System Type Injection Pump
Gas Odorized Level 0.4
Scada In Place Ind No
Accident Identifier Notification From Emergency Responder
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details Pressure did not exceed detection threshold of the system.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Excavation Damage
Cause Details Excavation Damage By Third Party
Ex Party Type Excavation Damage By Third Party
Prior Notification Ind Yes
One Call System Ind Yes
Excavator Ind Yes
Contractor Ind Yes
State Law Exempt Ind No
Notify Cga Dirt Yes
Private Row Ind Yes
Private Subtype Private Landowner
Joint Trench Ind No
Cross Bore Ind No
Depth Of Grade < 18�
Excavator Type Contractor
Excavator Equipment Hand Tools
Work Performed Unknown/other
One Call Notified Ind Yes
One Call Ticket Num 246768597.0
One Call Center Name 811
White Lined Ind No
Locator Type Contract Locator
Visible Marks Yes
Service Interruption No
Root Cause Category Excavation Issue
Root Cause Type Excavator Failed To Maintain Clearance After Verifying Marks
Preparer Name E**** S******
Preparer Title Operations Specialist
Preparer Email E************@c****************.com
Preparer Telephone 281-755-2470
Local Contact Name E**** S******
Local Contact Email E************@c****************.com
Local Contact Telephone 281-755-2470
Authorizer Name P****** G****
Authorizer Title Manager Gas Compliance South
Authorizer Telephone 713-378-9845
Authorizer Email P************@c****************.com
Narrative On july 2, 2024, ram jack foundation solutions were performing foundation repairs at 15602 four seasons. While excavating with hand tools, the properly marked gas service line at this location was struck. The escaping gas ignited, resulting in fire damage to the single-story structure. The fire department responded and notified centerpoint energy at 11:45am. Service technician arrived at 12:11pm, gas was shut off at 1:45pm, line was squeezed off at the service tap location by the fire department on site and centerpoint energy personnel. Additionally, this same service line was struck on july 1, 2024, by the same 3rd party excavator, ram jack foundation solutions. Centerpoint energy responded and made repairs on july 1,2024.

All rights reserved. Copyright © by ClearPHMSA