GD incident on 2024-04-24 — GA

Operator
Atlanta Gas Light Co
Cause
Excavation Issue
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$80,079
Incident datetime
2024-04-24 00:00 UTC
Report number
Location
GA, FULTON
Narrative
A third-party party excavator (nextier infrastructure solutions) struck and damaged an atlanta gas light company (aglc) 6-inch plastic gas main while directionally boring to install telecommunication fiber main near 2661 campbellton road sw, atlanta. Escaping gas from the damage migrated to a nearby structure at 2683 campbellton road sw, atlanta (po freddie's bbq restaurant) and was ignited by an unknown ignition source where a subsequent explosion and fire occurred at the restaurant resulting in significant property damage. At least one vehicle was damaged by falling debris from the explosion. Upon arrival, aglc personnel worked with emergency responders to secure the area and monitor the surrounding area for gas. Gas was shut-off to the damaged area at 14:00 hours by performing four (4) squeeze-off operations. A large project marking ' utility facility locating agreement was signed on may 5, 2023, with nextier infrastructure solutions (excavator) to locate the area as a large project excavation. As to the location of this incident, the large project marking agreement stated 'continue locates east on the north side of campbellton road sw to the northwest corner of campbellton road sw and dodson drive sw. Locate this corner 50 feet in all directions. Then continue east on the north side of campbellton road sw to the northwest corner of willis mill road and campbellton road sw and locate it 50 feet in all directions'. Aglc facilities were last marked by stake center locating to satisfy this request on march 13, 2024. Investigation of the site revealed that the locate marks were accurate at the point of damage, however, because the excavator did not verify the location and depth of aglc facilities by pot holing and instead blindly crossed the marks on the ground, the gas main was damaged. Aglc initially notified the national response center (nrc) under nrc report number 1394734. Additional nrc report number 1394916 was created for the same event after a supplemental call was placed with the nrc to update the initial telephonic notice.
Detailed record list
Report Received Date
2024-04-24 00:00:00
Iyear
2024.0
Report Number
20240026.0
Supplemental Number
39479.0
Report Type
Original Final
Operator Id
Name
Atlanta Gas Light Co
Operator Street Address
10 Peachtree Place Ne
Operator City Name
Atlanta
Operator State Abbreviation
GA
Operator Postal Code
30309.0
Time Zone
Eastern
Daylight Savings Ind
Yes
Location Street Address
2661 Campbellton Road Sw
Location City Name
Atanta
Location County Name
Fulton
Location State Abbreviation
GA
Location Postal Code
30311.0
Location Latitude
Location Longitude
Flow Cont Squeeze Off Ind
Yes
Nrc Rpt Num
Additional Nrc Report Numbers
1394916.0
Commodity Released Type
Natural Gas
Unintentional Release
4352.1
Intentional Release
0.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
Yes
How Extinguished
Local/state/federal Emergency Responder
Gas Consumed By Fire In Mcf
1614
Explode Ind
Yes
Num Pub Evacuated
20.0
Federal
No
Location Type
Public Property
Incident Area Type
Underground
Incident Area Subtype
Under Pavement
Depth Of Cover
96.0
Other Underground Facilities
No
Crossing
Yes
Road Crossing Ind
Yes
Road Type
Uncased, Bored/drilled
Pipe Facility Type
Investor Owned
System Part Involved
Main
Installation Year
2011.0
Pipe Diameter
6.0
Pipe Specification
Astm D2513
Pipe Manufacturer
Drisco
Material Involved
Plastic
Plastic Type
Polyethylene (Pe)
Plastic Sdr
11.5
Material Pe Pipe Code
2406
Release Type
Mechanical Puncture
Puncture Axial
4.5
Puncture Circum
4.5
Class Location Type
Class 3 Location
Est Cost Oper Paid
300000.0
Est Cost Prop Damage
80079.0
Est Cost Emergency
108314.0
Est Cost Other
0.0
Gas Cost In Mcf
1.45
Est Cost Unintentional Release
6311.0
Est Cost Intentional Release
0.0
Prpty
494704.0
Commercial Affected
1.0
Industrial Affected
0.0
Residences Affected
0.0
Num Persons Hosp Not Ovnght
0.0
Num Injured Treated By Emt
0.0
Num Resident Building Affctd
0.0
Num Business Building Affctd
1.0
Accident Psig
39.0
Normal Psig
39.0
Mop Psig
45.0
Mop Cfr Section
192.619(A)(2)
Maop Established Date
2011-04-16 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
Injection Pump
Gas Odorized Level
13
Scada In Place Ind
No
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
Yes
Num Employees Tested
13
Num Employees Failed
0
Contractor Drug Test Ind
Yes
Num Contractors Tested
1
Num Contractors Failed
0
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
Yes
One Call System Ind
Yes
State Law Exempt Ind
No
Notify Cga Dirt
Yes
Public Row Ind
Yes
Public Subtype
City Street
Joint Trench Ind
No
Cross Bore Ind
No
Depth Of Grade
> 36�
Excavator Type
Contractor
Excavator Equipment
Directional Drilling
Work Performed
Telecommunications
One Call Notified Ind
Yes
One Call Ticket Num
240112000000.0
White Lined Ind
No
Locator Type
Contract Locator
Visible Marks
Yes
Service Interruption
Yes
Service Interruption Hours
13.0
Root Cause Category
Excavation Issue
Root Cause Type
Excavator Dug Prior To Verifying Marks By Test-Hole (Pothole)
Preparer Name
R**** M*******
Preparer Title
Principal Compliance Engineer
Preparer Email
R*******@s*********.com
Preparer Telephone
(404) 584-3733
Preparer Fax
(404) 584-4710
Authorizer Name
R*** S*****
Authorizer Title
Manager Compliance And Qa
Authorizer Telephone
(404) 584-4910
Authorizer Email
R******@s*********.com
Narrative
A third-party party excavator (nextier infrastructure solutions) struck and damaged an atlanta gas light company (aglc) 6-inch plastic gas main while directionally boring to install telecommunication fiber main near 2661 campbellton road sw, atlanta. Escaping gas from the damage migrated to a nearby structure at 2683 campbellton road sw, atlanta (po freddie's bbq restaurant) and was ignited by an unknown ignition source where a subsequent explosion and fire occurred at the restaurant resulting in significant property damage. At least one vehicle was damaged by falling debris from the explosion. Upon arrival, aglc personnel worked with emergency responders to secure the area and monitor the surrounding area for gas. Gas was shut-off to the damaged area at 14:00 hours by performing four (4) squeeze-off operations. A large project marking ' utility facility locating agreement was signed on may 5, 2023, with nextier infrastructure solutions (excavator) to locate the area as a large project excavation. As to the location of this incident, the large project marking agreement stated 'continue locates east on the north side of campbellton road sw to the northwest corner of campbellton road sw and dodson drive sw. Locate this corner 50 feet in all directions. Then continue east on the north side of campbellton road sw to the northwest corner of willis mill road and campbellton road sw and locate it 50 feet in all directions'. Aglc facilities were last marked by stake center locating to satisfy this request on march 13, 2024. Investigation of the site revealed that the locate marks were accurate at the point of damage, however, because the excavator did not verify the location and depth of aglc facilities by pot holing and instead blindly crossed the marks on the ground, the gas main was damaged. Aglc initially notified the national response center (nrc) under nrc report number 1394734. Additional nrc report number 1394916 was created for the same event after a supplemental call was placed with the nrc to update the initial telephonic notice.
Report Received Date 2024-04-24 00:00:00
Iyear 2024.0
Report Number 20240026.0
Supplemental Number 39479.0
Report Type Original Final
Operator Id 792 PHMSA Enforcement
Name Atlanta Gas Light Co
Operator Street Address 10 Peachtree Place Ne
Operator City Name Atlanta
Operator State Abbreviation GA
Operator Postal Code 30309.0
Time Zone Eastern
Daylight Savings Ind Yes
Location Street Address 2661 Campbellton Road Sw
Location City Name Atanta
Location County Name Fulton
Location State Abbreviation GA
Location Postal Code 30311.0
Location Latitude 33.702399 Google Maps OpenStreetMap
Location Longitude -84.476137 Google Maps OpenStreetMap
Flow Cont Squeeze Off Ind Yes
Nrc Rpt Num 1394734.0 NRC Report How to search
Additional Nrc Report Numbers 1394916.0
Commodity Released Type Natural Gas
Unintentional Release 4352.1
Intentional Release 0.0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Ignite Ind Yes
How Extinguished Local/state/federal Emergency Responder
Gas Consumed By Fire In Mcf 1614
Explode Ind Yes
Num Pub Evacuated 20.0
Federal No
Location Type Public Property
Incident Area Type Underground
Incident Area Subtype Under Pavement
Depth Of Cover 96.0
Other Underground Facilities No
Crossing Yes
Road Crossing Ind Yes
Road Type Uncased, Bored/drilled
Pipe Facility Type Investor Owned
System Part Involved Main
Installation Year 2011.0
Pipe Diameter 6.0
Pipe Specification Astm D2513
Pipe Manufacturer Drisco
Material Involved Plastic
Plastic Type Polyethylene (Pe)
Plastic Sdr 11.5
Material Pe Pipe Code 2406
Release Type Mechanical Puncture
Puncture Axial 4.5
Puncture Circum 4.5
Class Location Type Class 3 Location
Est Cost Oper Paid 300000.0
Est Cost Prop Damage 80079.0
Est Cost Emergency 108314.0
Est Cost Other 0.0
Gas Cost In Mcf 1.45
Est Cost Unintentional Release 6311.0
Est Cost Intentional Release 0.0
Prpty 494704.0
Commercial Affected 1.0
Industrial Affected 0.0
Residences Affected 0.0
Num Persons Hosp Not Ovnght 0.0
Num Injured Treated By Emt 0.0
Num Resident Building Affctd 0.0
Num Business Building Affctd 1.0
Accident Psig 39.0
Normal Psig 39.0
Mop Psig 45.0
Mop Cfr Section 192.619(A)(2) View CFR 49 §192
Maop Established Date 2011-04-16 00:00:00
Accident Pressure Pressure Did Not Exceed Maop
Gas Odorized System Type Injection Pump
Gas Odorized Level 13
Scada In Place Ind No
Accident Identifier Notification From Emergency Responder
Investigation Status No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind Yes
Num Employees Tested 13
Num Employees Failed 0
Contractor Drug Test Ind Yes
Num Contractors Tested 1
Num Contractors Failed 0
Cause Excavation Damage
Cause Details Excavation Damage By Third Party
Ex Party Type Excavation Damage By Third Party
Prior Notification Ind Yes
One Call System Ind Yes
State Law Exempt Ind No
Notify Cga Dirt Yes
Public Row Ind Yes
Public Subtype City Street
Joint Trench Ind No
Cross Bore Ind No
Depth Of Grade > 36�
Excavator Type Contractor
Excavator Equipment Directional Drilling
Work Performed Telecommunications
One Call Notified Ind Yes
One Call Ticket Num 240112000000.0
White Lined Ind No
Locator Type Contract Locator
Visible Marks Yes
Service Interruption Yes
Service Interruption Hours 13.0
Root Cause Category Excavation Issue
Root Cause Type Excavator Dug Prior To Verifying Marks By Test-Hole (Pothole)
Preparer Name R**** M*******
Preparer Title Principal Compliance Engineer
Preparer Email R*******@s*********.com
Preparer Telephone (404) 584-3733
Preparer Fax (404) 584-4710
Authorizer Name R*** S*****
Authorizer Title Manager Compliance And Qa
Authorizer Telephone (404) 584-4910
Authorizer Email R******@s*********.com
Narrative A third-party party excavator (nextier infrastructure solutions) struck and damaged an atlanta gas light company (aglc) 6-inch plastic gas main while directionally boring to install telecommunication fiber main near 2661 campbellton road sw, atlanta. Escaping gas from the damage migrated to a nearby structure at 2683 campbellton road sw, atlanta (po freddie's bbq restaurant) and was ignited by an unknown ignition source where a subsequent explosion and fire occurred at the restaurant resulting in significant property damage. At least one vehicle was damaged by falling debris from the explosion. Upon arrival, aglc personnel worked with emergency responders to secure the area and monitor the surrounding area for gas. Gas was shut-off to the damaged area at 14:00 hours by performing four (4) squeeze-off operations. A large project marking ' utility facility locating agreement was signed on may 5, 2023, with nextier infrastructure solutions (excavator) to locate the area as a large project excavation. As to the location of this incident, the large project marking agreement stated 'continue locates east on the north side of campbellton road sw to the northwest corner of campbellton road sw and dodson drive sw. Locate this corner 50 feet in all directions. Then continue east on the north side of campbellton road sw to the northwest corner of willis mill road and campbellton road sw and locate it 50 feet in all directions'. Aglc facilities were last marked by stake center locating to satisfy this request on march 13, 2024. Investigation of the site revealed that the locate marks were accurate at the point of damage, however, because the excavator did not verify the location and depth of aglc facilities by pot holing and instead blindly crossed the marks on the ground, the gas main was damaged. Aglc initially notified the national response center (nrc) under nrc report number 1394734. Additional nrc report number 1394916 was created for the same event after a supplemental call was placed with the nrc to update the initial telephonic notice.

All rights reserved. Copyright © by ClearPHMSA