HL incident on 2023-12-20 — OK

Operator
Oneok Ngl Pipeline, Llc
Cause
Corrosion Failure
Commodity
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$78,000
Incident datetime
2023-12-20 00:00 UTC
Report number
Location
OK
Narrative
On november 27th, 2023 at 1:15pm the oneok pipeline control center was contacted by an oneok contractor stating frost on the ground in the vicinity of oneok's 6" tecumseh pipeline. The pipeline section was isolated, blocked in, and nitrogen purged. A pinhole leak was found on the pipe and repairs were made by pipe replacement. The removed pipe will be sent to a lab for metallurgical analysis. Results from the analysis will be included in the supplemental report once the investigation is complete. 05/13/24 update: the metallurgical report identified that the leak occurred within a region of external corrosion. Based on examination of the deposits and metallography across the leak, the observed external corrosion occurred in an environment containing water and oxygen due to a trapped environment present beneath disbonded tape coating. Due to the condition of the coating, shielding was present that did not allow cathodic protection current to reach the pipe surface leading to the observed higher corrosion rates. Approximately 10 feet of pipe was replaced at the leak location.
Detailed record list
Report Received Date
2023-12-20 00:00:00
Iyear
2023
Report Number
20230304
Supplemental Number
39544
Report Type
Supplemental Final
Operator Id
Name
Oneok Ngl Pipeline, Llc
Operator Street Address
100 West Fifth Street
Operator City Name
Tulsa
Operator State Abbreviation
OK
Operator Postal Code
74103
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype
Lpg (Liquefied Petroleum Gas) / Ngl (Natural Gas Liquid)
Unintentional Release Bbls
4.1
Intentional Release Bbls
27.5
Recovered Bbls
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Contractor Working For The Operator
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Nrc Rpt Num
Additional Nrc Report Numbers
1385421
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Type Ind
Manual
Downstream Action Taken
Valve Closure
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
Tecumseh Ada Jct To Tecumseh Plant
Segment Name
10187
Onshore State Abbreviation
Ok
Onshore Postal Code
74826
Onshore City Name
Not Within A Municipality
Onshore County Name
Pottawatomie
Designated Location
Survey Station No.
Designated Name
54838.44
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
42
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Body
Puddle Weld Ind
No
Pipe Diameter
6
Pipe Wall Thickness
0.156
Pipe Smys
42000
Pipe Specification
Api 5l
Pipe Seam Type
Erw - High Frequency
Pipe Manufacturer
Textube
Pipe Coating Type
Cold Applied Tape
Coating Applied Ind
Yes
Installation Year
1988
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
No
Est Cost Oper Paid
1500
Est Cost Gas Released
100
Est Cost Prop Damage
78000
Est Cost Emergency
0
Est Cost Environmental
33000
Est Cost Other
8500
Est Cost Other Details
Metallurgical Testing Of The Pipe
Prpty
121100
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
650
Mop Psig
1440
Mop Cfr Section
Component Design Pressure �195.406(A)(2)
Maop Established Date
1988-12-09 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
56733
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
No controller actions had taken place prior to the leak on this pipeline.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Other Corrosion Ind
Yes
Corrosion Type Details
External Corrosion Beneath Disbonded Tape Coating
Field Exam Basis Ind
Yes
Metallurgical Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
1989
Shielding Evident
Yes
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Cp Annual Survey Year
2023
Prior Damage
Yes
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Geometry Deformation Ind
Yes
Axial Recent Year
2023
Axial Rcnt Propul Method
Free Swimming
Axial Rcnt Attuned Detect
Metal Loss
Axial Rcnt Atnd Dtct Metal
High Resolution
Axial Previous Year
2018
Axial Prev Propul Method
Free Swimming
Axial Prev Attuned Detect
Metal Loss
Axial Prev Atnd Dtct Metal
High Resolution
Geometry Recent Year
2023
Geometry Rcnt Propul Method
Free Swimming
Geometry Rcnt Resolution
High Resolution
Geometrt Rcnt Measur Cups
No Cups
Geometry Previous Year
2018
Geometry Prev Propul Method
Free Swimming
Geometry Prev Resolution
High Resolution
Geometrt Prev Measur Cups
No Cups
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
P**** G**** R****
Preparer Title
Regulatory Compliance Specialist
Preparer Email
P***************@o****.com
Preparer Telephone
5803956238
Prepared Date
2024-05-13 00:00:00
Local Contact Name
P**** G**** R****
Local Contact Email
P***************@o****.com
Local Contact Telephone
5803956238
Authorizer Name
M*** G******
Authorizer Telephone
918-588-7382
Authorizer Title
Vp Natrual Gas Liquids Pipelines And Terminals
Authorizer Email
M**************@o****.com
Narrative
On november 27th, 2023 at 1:15pm the oneok pipeline control center was contacted by an oneok contractor stating frost on the ground in the vicinity of oneok's 6" tecumseh pipeline. The pipeline section was isolated, blocked in, and nitrogen purged. A pinhole leak was found on the pipe and repairs were made by pipe replacement. The removed pipe will be sent to a lab for metallurgical analysis. Results from the analysis will be included in the supplemental report once the investigation is complete. 05/13/24 update: the metallurgical report identified that the leak occurred within a region of external corrosion. Based on examination of the deposits and metallography across the leak, the observed external corrosion occurred in an environment containing water and oxygen due to a trapped environment present beneath disbonded tape coating. Due to the condition of the coating, shielding was present that did not allow cathodic protection current to reach the pipe surface leading to the observed higher corrosion rates. Approximately 10 feet of pipe was replaced at the leak location.
Report Received Date 2023-12-20 00:00:00
Iyear 2023
Report Number 20230304
Supplemental Number 39544
Report Type Supplemental Final
Operator Id 32109 PHMSA Enforcement
Name Oneok Ngl Pipeline, Llc
Operator Street Address 100 West Fifth Street
Operator City Name Tulsa
Operator State Abbreviation OK
Operator Postal Code 74103
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 35.06654 Google Maps OpenStreetMap
Location Longitude -96.89865 Google Maps OpenStreetMap
Commodity Released Type Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype Lpg (Liquefied Petroleum Gas) / Ngl (Natural Gas Liquid)
Unintentional Release Bbls 4.1
Intentional Release Bbls 27.5
Recovered Bbls 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Contractor Working For The Operator
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind Yes
Communication State Fed Ind Yes
Party Initiated Communication Operator
Nrc Rpt Num 1385269 NRC Report How to search
Additional Nrc Report Numbers 1385421
Ignite Ind No
Upstream Action Taken Valve Closure
Upstream Valve Type Ind Manual
Downstream Action Taken Valve Closure
Downstream Valve Type Ind Manual
Num Pub Evacuated 0
Pipe Fac Name Tecumseh Ada Jct To Tecumseh Plant
Segment Name 10187
Onshore State Abbreviation Ok
Onshore Postal Code 74826
Onshore City Name Not Within A Municipality
Onshore County Name Pottawatomie
Designated Location Survey Station No.
Designated Name 54838.44
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 42
Crossing No
Pipe Facility Type Intrastate
Item Involved Pipe
Pipe Type Pipe Body
Puddle Weld Ind No
Pipe Diameter 6
Pipe Wall Thickness 0.156
Pipe Smys 42000
Pipe Specification Api 5l
Pipe Seam Type Erw - High Frequency
Pipe Manufacturer Textube
Pipe Coating Type Cold Applied Tape
Coating Applied Ind Yes
Installation Year 1988
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination No
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca No
Est Cost Oper Paid 1500
Est Cost Gas Released 100
Est Cost Prop Damage 78000
Est Cost Emergency 0
Est Cost Environmental 33000
Est Cost Other 8500
Est Cost Other Details Metallurgical Testing Of The Pipe
Prpty 121100
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 650
Mop Psig 1440
Mop Cfr Section Component Design Pressure �195.406(A)(2) View CFR 49 §192
Maop Established Date 1988-12-09 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 56733
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind No
Cpm Conf Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details No controller actions had taken place prior to the leak on this pipeline.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details External Corrosion
Internal External External Corrosion
Visual Exam Results Localized Pitting
Other Corrosion Ind Yes
Corrosion Type Details External Corrosion Beneath Disbonded Tape Coating
Field Exam Basis Ind Yes
Metallurgical Basis Ind Yes
Underground Location Yes
Under Cathodic Protection Ind Yes
Cathodic Pro Start Year 1989
Shielding Evident Yes
Cathodic Survey Type Yes
Cp Annual Survey Ind Yes
Cp Annual Survey Year 2023
Prior Damage Yes
Collected Data Ind Yes
Axial Magnetic Flx Lkg Ind Yes
Geometry Deformation Ind Yes
Axial Recent Year 2023
Axial Rcnt Propul Method Free Swimming
Axial Rcnt Attuned Detect Metal Loss
Axial Rcnt Atnd Dtct Metal High Resolution
Axial Previous Year 2018
Axial Prev Propul Method Free Swimming
Axial Prev Attuned Detect Metal Loss
Axial Prev Atnd Dtct Metal High Resolution
Geometry Recent Year 2023
Geometry Rcnt Propul Method Free Swimming
Geometry Rcnt Resolution High Resolution
Geometrt Rcnt Measur Cups No Cups
Geometry Previous Year 2018
Geometry Prev Propul Method Free Swimming
Geometry Prev Resolution High Resolution
Geometrt Prev Measur Cups No Cups
Has Hydrtst Conduc Before Ind No
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name P**** G**** R****
Preparer Title Regulatory Compliance Specialist
Preparer Email P***************@o****.com
Preparer Telephone 5803956238
Prepared Date 2024-05-13 00:00:00
Local Contact Name P**** G**** R****
Local Contact Email P***************@o****.com
Local Contact Telephone 5803956238
Authorizer Name M*** G******
Authorizer Telephone 918-588-7382
Authorizer Title Vp Natrual Gas Liquids Pipelines And Terminals
Authorizer Email M**************@o****.com
Narrative On november 27th, 2023 at 1:15pm the oneok pipeline control center was contacted by an oneok contractor stating frost on the ground in the vicinity of oneok's 6" tecumseh pipeline. The pipeline section was isolated, blocked in, and nitrogen purged. A pinhole leak was found on the pipe and repairs were made by pipe replacement. The removed pipe will be sent to a lab for metallurgical analysis. Results from the analysis will be included in the supplemental report once the investigation is complete. 05/13/24 update: the metallurgical report identified that the leak occurred within a region of external corrosion. Based on examination of the deposits and metallography across the leak, the observed external corrosion occurred in an environment containing water and oxygen due to a trapped environment present beneath disbonded tape coating. Due to the condition of the coating, shielding was present that did not allow cathodic protection current to reach the pipe surface leading to the observed higher corrosion rates. Approximately 10 feet of pipe was replaced at the leak location.