Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2023-12-19 — TX
Operator
Centurion Pipeline L.p.
Cause
Equipment Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$100
Incident datetime
2023-12-19 00:00 UTC
Report number
Location
TX
Narrative
On november 25, 2023, at approximately 09:00am cst, a company employee discovered a leak in airport junction station near denver city, texas. The employee determined the source of the leak to be a station pump and promptly isolated the leak. Ten (10) gallons of crude oil was released and was contained completely on-site. The contaminated soil will be remediated on-site. No injuries, fatalities or fires were associated with this incident. Texas railroad commission, office of pipeline safety was notified of the leak at 09:50 am cst on november 25, 2023. A notification to the national response center (nrc) was not required.
Detailed record list
Report Received Date
2023-12-19 00:00:00
Iyear
2023
Report Number
20230303
Supplemental Number
38981
Report Type
Original Final
Operator Id
31888
Name
Centurion Pipeline L.p.
Operator Street Address
1300 Main Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
32.9746128
Location Longitude
-102.8499035
Commodity Released Type
Crude Oil
Unintentional Release Bbls
0.2
Recovered Bbls
0.2
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Communication State Fed Ind
No
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Notify Qualified Indiv Ind
Yes
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Airport Junction Station
Segment Name
Airport Junction Trunk 3
Onshore State Abbreviation
Tx
Onshore Postal Code
79323
Onshore City Name
Not Within A Municipality
Onshore County Name
Yoakum
Designated Location
Milepost
Designated Name
Airport Jct
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pump
Pump Type
Positive Displacement
Pump Service Type
Mainline
Installation Year
Unknown
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Seal Or Packing
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
Usa Drinking Ind
Yes
Usa Drinking Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
20
Est Cost Prop Damage
100
Est Cost Emergency
5000
Est Cost Environmental
1600
Est Cost Other
0
Prpty
6720
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
15
Mop Psig
720
Mop Cfr Section
Subpart E Pressure Test �195.406(A)(3)
Maop Established Date
2016-08-25 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the accident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Pump Or Pump-Related Equipment
Eq Failure Type
Pump Or Pump-Related Equipment
Other Pump Ind
Seal/packing Failure
Additional Erosion Wear Ind
Yes
Preparer Name
Y*** T*
Preparer Title
Senior Dot Compliance Specialist
Preparer Email
Y******@e*************.com
Preparer Telephone
713-989-7895
Prepared Date
2023-12-19 00:00:00
Authorizer Name
T***** D*****
Authorizer Telephone
832-808-9234
Authorizer Title
Dot Compliance Manager
Authorizer Email
T************@e*************.com
Narrative
On november 25, 2023, at approximately 09:00am cst, a company employee discovered a leak in airport junction station near denver city, texas. The employee determined the source of the leak to be a station pump and promptly isolated the leak. Ten (10) gallons of crude oil was released and was contained completely on-site. The contaminated soil will be remediated on-site. No injuries, fatalities or fires were associated with this incident. Texas railroad commission, office of pipeline safety was notified of the leak at 09:50 am cst on november 25, 2023. A notification to the national response center (nrc) was not required.
Report Received Date | 2023-12-19 00:00:00 |
---|---|
Iyear | 2023 |
Report Number | 20230303 |
Supplemental Number | 38981 |
Report Type | Original Final |
Operator Id | 31888 PHMSA Enforcement |
Name | Centurion Pipeline L.p. |
Operator Street Address | 1300 Main Street |
Operator City Name | Houston |
Operator State Abbreviation | TX |
Operator Postal Code | 77002 |
Time Zone | Central |
Daylight Savings Ind | Yes |
Location Latitude | 32.9746128 Google Maps OpenStreetMap |
Location Longitude | -102.8499035 Google Maps OpenStreetMap |
Commodity Released Type | Crude Oil |
Unintentional Release Bbls | 0.2 |
Recovered Bbls | 0.2 |
Fatality Ind | No |
Fatal | 0 |
Injury Ind | No |
Injure | 0 |
Accident Identifier | Local Operating Personnel, Including Contractors |
Operator Type | Operator Employee |
System Part Involved | Onshore Pump/meter Station Equipment And Piping |
On Off Shore | Onshore |
Status When Identified | Normal Operation, Includes Pauses Between Batches And During Maintenance |
Shutdown Due Accident Ind | Yes |
Communication State Fed Ind | No |
Nrc Rpt Num | Nrc Notification Not Required NRC Report How to search |
Ignite Ind | No |
Notify Qualified Indiv Ind | Yes |
Oil Spill Removal Org Ind | No |
Num Pub Evacuated | 0 |
Pipe Fac Name | Airport Junction Station |
Segment Name | Airport Junction Trunk 3 |
Onshore State Abbreviation | Tx |
Onshore Postal Code | 79323 |
Onshore City Name | Not Within A Municipality |
Onshore County Name | Yoakum |
Designated Location | Milepost |
Designated Name | Airport Jct |
Federal | No |
Location Type | Totally Contained On Operator-Controlled Property |
Incident Area Type | Aboveground |
Incident Area Subtype | Typical Aboveground Facility Piping Or Appurtenance |
Crossing | No |
Pipe Facility Type | Intrastate |
Item Involved | Pump |
Pump Type | Positive Displacement |
Pump Service Type | Mainline |
Installation Year | Unknown |
Manufactured Year | Unknown |
Material Involved | Carbon Steel |
Release Type | Leak |
Leak Type | Seal Or Packing |
Wildlife Impact Ind | No |
Soil Contamination | Yes |
Long Term Assessment | No |
Remediation Ind | Yes |
Soil Remed Ind | Yes |
Water Contam Ind | No |
Could Be Hca | Yes |
Commodity Reached Hca | Yes |
Usa Drinking Ind | Yes |
Usa Drinking Yes No | Yes |
Est Cost Oper Paid | 0 |
Est Cost Gas Released | 20 |
Est Cost Prop Damage | 100 |
Est Cost Emergency | 5000 |
Est Cost Environmental | 1600 |
Est Cost Other | 0 |
Prpty | 6720 |
Num Persons Hosp Not Ovnght | 0 |
Num Injured Treated By Emt | 0 |
Num Resident Building Affctd | 0 |
Num Business Building Affctd | 0 |
Accident Psig | 15 |
Mop Psig | 720 |
Mop Cfr Section | Subpart E Pressure Test �195.406(A)(3) View CFR 49 §192 |
Maop Established Date | 2016-08-25 00:00:00 |
Maop Reversal Flow Ind | No |
Accident Pressure | Pressure Did Not Exceed Mop |
Pressure Restriction Ind | No |
Pipeline Function | > 20% Smys Regulated Transmission |
Scada In Place Ind | Yes |
Scada Operating Ind | Yes |
Scada Functional Ind | Yes |
Scada Detection Ind | No |
Scada Conf Ind | No |
Cpm In Place Ind | No |
Investigation Status | No, the facility was not monitored by a controller(s) at the time of the accident |
Employee Drug Test Ind | No |
Contractor Drug Test Ind | No |
Cause | Equipment Failure |
Cause Details | Pump Or Pump-Related Equipment |
Eq Failure Type | Pump Or Pump-Related Equipment |
Other Pump Ind | Seal/packing Failure |
Additional Erosion Wear Ind | Yes |
Preparer Name | Y*** T* |
Preparer Title | Senior Dot Compliance Specialist |
Preparer Email | Y******@e*************.com |
Preparer Telephone | 713-989-7895 |
Prepared Date | 2023-12-19 00:00:00 |
Authorizer Name | T***** D***** |
Authorizer Telephone | 832-808-9234 |
Authorizer Title | Dot Compliance Manager |
Authorizer Email | T************@e*************.com |
Narrative | On november 25, 2023, at approximately 09:00am cst, a company employee discovered a leak in airport junction station near denver city, texas. The employee determined the source of the leak to be a station pump and promptly isolated the leak. Ten (10) gallons of crude oil was released and was contained completely on-site. The contaminated soil will be remediated on-site. No injuries, fatalities or fires were associated with this incident. Texas railroad commission, office of pipeline safety was notified of the leak at 09:50 am cst on november 25, 2023. A notification to the national response center (nrc) was not required. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA