HL incident on 2023-11-30 — TX

Operator
Phillips 66 Pipeline Llc
Cause
Notification Issue
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$362,560
Incident datetime
2023-11-30 00:00 UTC
Report number
Location
TX
Narrative
The phillips 66 bartlesville control center received an emergency line call at 13:37, 11/2/23. The caller reported petroleum product escaping from an excavation. This call was made by the contractor who was operating an auger directly over the gd03 line. The line was shut down and blocked in within 6 minutes of the commencement of the emergency line call. There was no active one-call ticket for the auger work, thus p66 personnel were not on site. The auger pierced the pipe very close to the 12:00 position. The pipe has apx 84" of dirt cover at the incident location. The line was initially blocked in with two remote operated valves' positions separated by apx 14 miles. Local p66 personnel arrived and manually closed two additional valves that reduced the affected pipeline distance to apx 4 miles. This occurred in a p66 r-o-w through a baseball complex that is under construction. The line was excavated, contaminated soil removed and a repair clamp was installed. The line was returned to service on 11/4/23 at 15:35. 12/4/23 - part c, item #3a - changed from 12.75" dia to 12" nominal pipe dia, per PHMSA request. 12/4/23 - part e, items #9c & 10c - changed from "no" to "yes" at the insistence of PHMSA, since "yes" was normally what they see, though "no" accurately reflects accident conditions. 2/13/24 - part a, item #25 - updated public evac total to 661 after receiving data from the local fire department. 2/13/24 - part d, items #8c, 8d & 8e - updated accident costs 2/15/24 - part e, items 9c & 10c were changed back to the accurate response of "no" after discussion with PHMSA.
Detailed record list
Report Received Date
2023-11-30 00:00:00
Iyear
2023
Report Number
20230288
Supplemental Number
39191
Report Type
Supplemental Final
Operator Id
Name
Phillips 66 Pipeline Llc
Operator Street Address
2331 Citywest Blvd
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77042
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Gasoline (Non-Ethanol)
Unintentional Release Bbls
152
Recovered Bbls
140
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Third Party That Caused The Accident
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Nrc Rpt Num
Additional Nrc Report Numbers
1383415
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Type Ind
Remotely Controlled
Downstream Action Taken
Valve Closure
Downstream Valve Type Ind
Remotely Controlled
Notify Qualified Indiv Ind
Yes
Oil Spill Removal Org Ind
Yes
Osro Arrived On Site Dt
11/2/2023 16:00
Num Pub Evacuated
661
Pipe Fac Name
Gold Line
Segment Name
Gd03
Onshore State Abbreviation
Mo
Onshore Postal Code
63025
Onshore City Name
Eureka
Onshore County Name
St. Louis
Designated Location
Milepost
Designated Name
Mp 654
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
84
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Puddle Weld Ind
No
Pipe Diameter
12
Pipe Wall Thickness
0.25
Pipe Smys
46000
Pipe Specification
Api-5lx
Pipe Seam Type
Erw � Unknown Frequency
Pipe Manufacturer
Unknown
Pipe Coating Type
Coal Tar
Coating Applied Ind
Unknown
Installation Year
1952
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Mechanical Puncture
Puncture Axial
1.2
Puncture Circum
3.8
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
Yes
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
Other Pop Ind
Yes
Other Pop Yes No
Yes
Usa Drinking Ind
Yes
Usa Drinking Yes No
Yes
Est Cost Oper Paid
95000
Est Cost Gas Released
13451
Est Cost Prop Damage
362560
Est Cost Emergency
135000
Est Cost Environmental
1800000
Est Cost Other
0
Prpty
2406011
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
1
Accident Psig
263
Mop Psig
1045
Mop Cfr Section
Internal Design Pressure �195.406(A)(1)
Maop Established Date
2014-08-18 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
73920
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
Yes
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
Yes
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The event was caused by a third party field excavator and the controller responded reasonably to the event and minimized release volume.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
No
State Law Exempt Ind
No
Notify Cga Dirt
Yes
Public Row Ind
Yes
Public Subtype
Other
Pipeline Easement Row Ind
Yes
Joint Trench Ind
No
Cross Bore Ind
No
Depth Of Grade
Measured Depth From Grade
Depth Of Grade Detail
84
Excavator Type
Contractor
Excavator Equipment
Auger
Work Performed
Pole
One Call Notified Ind
No
Locator Type
Facility Owner
Visible Marks
No
Service Interruption
Yes
Service Interruption Hours
50
Root Cause Category
Notification Issue
Root Cause Type
No Notification Made To The One-Call Center/811
Excvtn Dmg Third Party Ind
Yes
Preparer Name
T** J****
Preparer Email
T**********@p**.com
Preparer Telephone
9183320983
Prepared Date
2024-02-15 00:00:00
Authorizer Name
T*** F****
Authorizer Telephone
832-765-1632
Authorizer Title
Director Dot Compliance
Authorizer Email
T***********@p**.com
Narrative
The phillips 66 bartlesville control center received an emergency line call at 13:37, 11/2/23. The caller reported petroleum product escaping from an excavation. This call was made by the contractor who was operating an auger directly over the gd03 line. The line was shut down and blocked in within 6 minutes of the commencement of the emergency line call. There was no active one-call ticket for the auger work, thus p66 personnel were not on site. The auger pierced the pipe very close to the 12:00 position. The pipe has apx 84" of dirt cover at the incident location. The line was initially blocked in with two remote operated valves' positions separated by apx 14 miles. Local p66 personnel arrived and manually closed two additional valves that reduced the affected pipeline distance to apx 4 miles. This occurred in a p66 r-o-w through a baseball complex that is under construction. The line was excavated, contaminated soil removed and a repair clamp was installed. The line was returned to service on 11/4/23 at 15:35. 12/4/23 - part c, item #3a - changed from 12.75" dia to 12" nominal pipe dia, per PHMSA request. 12/4/23 - part e, items #9c & 10c - changed from "no" to "yes" at the insistence of PHMSA, since "yes" was normally what they see, though "no" accurately reflects accident conditions. 2/13/24 - part a, item #25 - updated public evac total to 661 after receiving data from the local fire department. 2/13/24 - part d, items #8c, 8d & 8e - updated accident costs 2/15/24 - part e, items 9c & 10c were changed back to the accurate response of "no" after discussion with PHMSA.
Report Received Date 2023-11-30 00:00:00
Iyear 2023
Report Number 20230288
Supplemental Number 39191
Report Type Supplemental Final
Operator Id 31684 PHMSA Enforcement
Name Phillips 66 Pipeline Llc
Operator Street Address 2331 Citywest Blvd
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77042
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 38.49789 Google Maps OpenStreetMap
Location Longitude -90.629816 Google Maps OpenStreetMap
Commodity Released Type Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype Gasoline (Non-Ethanol)
Unintentional Release Bbls 152
Recovered Bbls 140
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Notification From Third Party That Caused The Accident
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind Yes
Communication State Fed Ind Yes
Party Initiated Communication Operator
Nrc Rpt Num 1383305 NRC Report How to search
Additional Nrc Report Numbers 1383415
Ignite Ind No
Upstream Action Taken Valve Closure
Upstream Valve Type Ind Remotely Controlled
Downstream Action Taken Valve Closure
Downstream Valve Type Ind Remotely Controlled
Notify Qualified Indiv Ind Yes
Oil Spill Removal Org Ind Yes
Osro Arrived On Site Dt 11/2/2023 16:00
Num Pub Evacuated 661
Pipe Fac Name Gold Line
Segment Name Gd03
Onshore State Abbreviation Mo
Onshore Postal Code 63025
Onshore City Name Eureka
Onshore County Name St. Louis
Designated Location Milepost
Designated Name Mp 654
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 84
Crossing No
Pipe Facility Type Interstate
Item Involved Pipe
Pipe Type Pipe Body
Puddle Weld Ind No
Pipe Diameter 12
Pipe Wall Thickness 0.25
Pipe Smys 46000
Pipe Specification Api-5lx
Pipe Seam Type Erw � Unknown Frequency
Pipe Manufacturer Unknown
Pipe Coating Type Coal Tar
Coating Applied Ind Unknown
Installation Year 1952
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Mechanical Puncture
Puncture Axial 1.2
Puncture Circum 3.8
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment Yes
Remediation Ind Yes
Soil Remed Ind Yes
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca Yes
Other Pop Ind Yes
Other Pop Yes No Yes
Usa Drinking Ind Yes
Usa Drinking Yes No Yes
Est Cost Oper Paid 95000
Est Cost Gas Released 13451
Est Cost Prop Damage 362560
Est Cost Emergency 135000
Est Cost Environmental 1800000
Est Cost Other 0
Prpty 2406011
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 1
Accident Psig 263
Mop Psig 1045
Mop Cfr Section Internal Design Pressure �195.406(A)(1) View CFR 49 §192
Maop Established Date 2014-08-18 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 73920
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind Yes
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind No
Cpm Conf Ind Yes
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details The event was caused by a third party field excavator and the controller responded reasonably to the event and minimized release volume.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Excavation Damage
Cause Details Excavation Damage By Third Party
Ex Party Type Excavation Damage By Third Party
Prior Notification Ind No
State Law Exempt Ind No
Notify Cga Dirt Yes
Public Row Ind Yes
Public Subtype Other
Pipeline Easement Row Ind Yes
Joint Trench Ind No
Cross Bore Ind No
Depth Of Grade Measured Depth From Grade
Depth Of Grade Detail 84
Excavator Type Contractor
Excavator Equipment Auger
Work Performed Pole
One Call Notified Ind No
Locator Type Facility Owner
Visible Marks No
Service Interruption Yes
Service Interruption Hours 50
Root Cause Category Notification Issue
Root Cause Type No Notification Made To The One-Call Center/811
Excvtn Dmg Third Party Ind Yes
Preparer Name T** J****
Preparer Email T**********@p**.com
Preparer Telephone 9183320983
Prepared Date 2024-02-15 00:00:00
Authorizer Name T*** F****
Authorizer Telephone 832-765-1632
Authorizer Title Director Dot Compliance
Authorizer Email T***********@p**.com
Narrative The phillips 66 bartlesville control center received an emergency line call at 13:37, 11/2/23. The caller reported petroleum product escaping from an excavation. This call was made by the contractor who was operating an auger directly over the gd03 line. The line was shut down and blocked in within 6 minutes of the commencement of the emergency line call. There was no active one-call ticket for the auger work, thus p66 personnel were not on site. The auger pierced the pipe very close to the 12:00 position. The pipe has apx 84" of dirt cover at the incident location. The line was initially blocked in with two remote operated valves' positions separated by apx 14 miles. Local p66 personnel arrived and manually closed two additional valves that reduced the affected pipeline distance to apx 4 miles. This occurred in a p66 r-o-w through a baseball complex that is under construction. The line was excavated, contaminated soil removed and a repair clamp was installed. The line was returned to service on 11/4/23 at 15:35. 12/4/23 - part c, item #3a - changed from 12.75" dia to 12" nominal pipe dia, per PHMSA request. 12/4/23 - part e, items #9c & 10c - changed from "no" to "yes" at the insistence of PHMSA, since "yes" was normally what they see, though "no" accurately reflects accident conditions. 2/13/24 - part a, item #25 - updated public evac total to 661 after receiving data from the local fire department. 2/13/24 - part d, items #8c, 8d & 8e - updated accident costs 2/15/24 - part e, items 9c & 10c were changed back to the accurate response of "no" after discussion with PHMSA.