Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2023-10-26 — KS
Operator
Great Salt Plains Pipeline Llc
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$9,291
Incident datetime
2023-10-26 00:00 UTC
Report number
Location
KS
Narrative
On 9-27-23 we received a call from energy transfer of a possible leak at the cushing meter station. Noticed oil coming out of the ground around the 4 inch kicker line from the pig trap. We hand dug the line up and found a leak on the 4 inch line underground. We replaced the bypass line and installed it above ground. The hole was located at 7:00.
Detailed record list
Report Received Date
2023-10-26 00:00:00
Iyear
2023
Report Number
20230251
Supplemental Number
38855
Report Type
Supplemental Final
Operator Id
39401
Name
Great Salt Plains Pipeline Llc
Operator Street Address
8301 E 21st St, Suite 370
Operator City Name
Wichita
Operator State Abbreviation
KS
Operator Postal Code
67206
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
36.02184
Location Longitude
-96.75489
Commodity Released Type
Crude Oil
Unintentional Release Bbls
1
Recovered Bbls
1
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Other
Accident Details
Energy Transfer Employee- It Was On Their Tank Farm
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Communication State Fed Ind
No
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Notify Qualified Indiv Ind
Yes
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Great Salt Plains Pipeline
Segment Name
Cushing Meter Station
Onshore State Abbreviation
Ok
Onshore Postal Code
74023
Onshore City Name
Cushing
Onshore County Name
Payne
Designated Location
Milepost
Designated Name
115
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
Unknown
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Body
Puddle Weld Ind
No
Pipe Diameter
4
Pipe Wall Thickness
0.237
Pipe Smys
52000
Pipe Specification
Api 5l X52
Pipe Seam Type
Erw - High Frequency
Pipe Manufacturer
Corpac Steel
Pipe Coating Type
Fusion Bonded Epoxy(Fbe)
Coating Applied Ind
Yes
Installation Year
2012
Manufactured Year
2012
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
Yes
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
80
Est Cost Prop Damage
9291
Est Cost Emergency
0
Est Cost Environmental
9956
Est Cost Other
0
Prpty
19327
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
30
Mop Psig
285
Mop Cfr Section
Internal Design Pressure �195.406(A)(1)
Maop Established Date
2012-10-01 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Too small of a leak.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
Internal Corrosion
Internal External
Internal Corrosion
Int Visual Exam Results
Localized Pitting
Int Water Acid Ind
Yes
Int Field Exam Basis Ind
Yes
Int Low Point Pipe Loc Ind
Yes
Corrosion Inhibitors
Yes
Corrosion Lining
No
Cleaning Dewatering
Not Applicable - Not Mainline Pipe
Corrosion Coupons
Not Applicable - Not Mainline Pipe
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
A*** C*****
Preparer Title
Manager Of Ehs
Preparer Email
A******@m**********.com
Preparer Telephone
6208860082
Prepared Date
2023-10-26 00:00:00
Local Contact Name
A*** C*****
Local Contact Email
A******@m**********.com
Local Contact Telephone
6208860082
Authorizer Name
A*** C*****
Authorizer Telephone
6208860082
Authorizer Title
Manager Of Ehs
Authorizer Email
A******@m**********.com
Narrative
On 9-27-23 we received a call from energy transfer of a possible leak at the cushing meter station. Noticed oil coming out of the ground around the 4 inch kicker line from the pig trap. We hand dug the line up and found a leak on the 4 inch line underground. We replaced the bypass line and installed it above ground. The hole was located at 7:00.
Report Received Date | 2023-10-26 00:00:00 |
---|---|
Iyear | 2023 |
Report Number | 20230251 |
Supplemental Number | 38855 |
Report Type | Supplemental Final |
Operator Id | 39401 PHMSA Enforcement |
Name | Great Salt Plains Pipeline Llc |
Operator Street Address | 8301 E 21st St, Suite 370 |
Operator City Name | Wichita |
Operator State Abbreviation | KS |
Operator Postal Code | 67206 |
Time Zone | Central |
Daylight Savings Ind | Yes |
Location Latitude | 36.02184 Google Maps OpenStreetMap |
Location Longitude | -96.75489 Google Maps OpenStreetMap |
Commodity Released Type | Crude Oil |
Unintentional Release Bbls | 1 |
Recovered Bbls | 1 |
Fatality Ind | No |
Fatal | 0 |
Injury Ind | No |
Injure | 0 |
Accident Identifier | Other |
Accident Details | Energy Transfer Employee- It Was On Their Tank Farm |
System Part Involved | Onshore Pump/meter Station Equipment And Piping |
On Off Shore | Onshore |
Status When Identified | Normal Operation, Includes Pauses Between Batches And During Maintenance |
Shutdown Due Accident Ind | Yes |
Communication State Fed Ind | No |
Nrc Rpt Num | Nrc Notification Not Required NRC Report How to search |
Ignite Ind | No |
Notify Qualified Indiv Ind | Yes |
Oil Spill Removal Org Ind | No |
Num Pub Evacuated | 0 |
Pipe Fac Name | Great Salt Plains Pipeline |
Segment Name | Cushing Meter Station |
Onshore State Abbreviation | Ok |
Onshore Postal Code | 74023 |
Onshore City Name | Cushing |
Onshore County Name | Payne |
Designated Location | Milepost |
Designated Name | 115 |
Federal | No |
Location Type | Totally Contained On Operator-Controlled Property |
Incident Area Type | Underground |
Incident Area Subtype | Under Soil |
Depth Of Cover | Unknown |
Crossing | No |
Pipe Facility Type | Intrastate |
Item Involved | Pipe |
Pipe Type | Pipe Body |
Puddle Weld Ind | No |
Pipe Diameter | 4 |
Pipe Wall Thickness | 0.237 |
Pipe Smys | 52000 |
Pipe Specification | Api 5l X52 |
Pipe Seam Type | Erw - High Frequency |
Pipe Manufacturer | Corpac Steel |
Pipe Coating Type | Fusion Bonded Epoxy(Fbe) |
Coating Applied Ind | Yes |
Installation Year | 2012 |
Manufactured Year | 2012 |
Material Involved | Carbon Steel |
Release Type | Leak |
Leak Type | Pinhole |
Wildlife Impact Ind | No |
Soil Contamination | Yes |
Long Term Assessment | Yes |
Remediation Ind | Yes |
Soil Remed Ind | Yes |
Water Contam Ind | No |
Could Be Hca | No |
Commodity Reached Hca | No |
Est Cost Oper Paid | 0 |
Est Cost Gas Released | 80 |
Est Cost Prop Damage | 9291 |
Est Cost Emergency | 0 |
Est Cost Environmental | 9956 |
Est Cost Other | 0 |
Prpty | 19327 |
Num Persons Hosp Not Ovnght | 0 |
Num Injured Treated By Emt | 0 |
Num Resident Building Affctd | 0 |
Num Business Building Affctd | 0 |
Accident Psig | 30 |
Mop Psig | 285 |
Mop Cfr Section | Internal Design Pressure �195.406(A)(1) View CFR 49 §192 |
Maop Established Date | 2012-10-01 00:00:00 |
Maop Reversal Flow Ind | No |
Accident Pressure | Pressure Did Not Exceed Mop |
Pressure Restriction Ind | No |
Pipeline Function | > 20% Smys Regulated Transmission |
Scada In Place Ind | Yes |
Scada Operating Ind | Yes |
Scada Functional Ind | Yes |
Scada Detection Ind | No |
Scada Conf Ind | No |
Cpm In Place Ind | Yes |
Cpm Operating Ind | Yes |
Cpm Functional Ind | Yes |
Cpm Detection Ind | No |
Cpm Conf Ind | No |
Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
Investigation Status Details | Too small of a leak. |
Employee Drug Test Ind | No |
Contractor Drug Test Ind | No |
Cause | Corrosion Failure |
Cause Details | Internal Corrosion |
Internal External | Internal Corrosion |
Int Visual Exam Results | Localized Pitting |
Int Water Acid Ind | Yes |
Int Field Exam Basis Ind | Yes |
Int Low Point Pipe Loc Ind | Yes |
Corrosion Inhibitors | Yes |
Corrosion Lining | No |
Cleaning Dewatering | Not Applicable - Not Mainline Pipe |
Corrosion Coupons | Not Applicable - Not Mainline Pipe |
Collected Data Ind | No |
Has Hydrtst Conduc Before Ind | No |
Direct Asmnt Conducted | No |
Non Destructive Exam Ind | No |
Preparer Name | A*** C***** |
Preparer Title | Manager Of Ehs |
Preparer Email | A******@m**********.com |
Preparer Telephone | 6208860082 |
Prepared Date | 2023-10-26 00:00:00 |
Local Contact Name | A*** C***** |
Local Contact Email | A******@m**********.com |
Local Contact Telephone | 6208860082 |
Authorizer Name | A*** C***** |
Authorizer Telephone | 6208860082 |
Authorizer Title | Manager Of Ehs |
Authorizer Email | A******@m**********.com |
Narrative | On 9-27-23 we received a call from energy transfer of a possible leak at the cushing meter station. Noticed oil coming out of the ground around the 4 inch kicker line from the pig trap. We hand dug the line up and found a leak on the 4 inch line underground. We replaced the bypass line and installed it above ground. The hole was located at 7:00. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA