HL incident on 2023-10-23 — CO

Operator
Mplx Lp
Cause
Equipment Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$6,800
Incident datetime
2023-10-23 00:00 UTC
Report number
Location
CO
Narrative
On 9/22/2023 at 9:00 am (mountain time), an mplx operator was doing a station check and noticed oil on the mainline pump containment. The operator called the controller to shut down pump ml-483 and notified the area supervisor. The supervisor dispatched a hydro-vac to assist with the cleanup of the containment and drain isolated segment on that pump. The pump seal failed recently as the operator had station checks the day before and walked through those pumps multiple times. The spare pump was put into service to avoid any downtime, and pump 483 was repaired and put back into service on 09/26/2023.
Detailed record list
Report Received Date
2023-10-23 00:00:00
Iyear
2023
Report Number
20230247
Supplemental Number
38692
Report Type
Original Final
Operator Id
Name
Mplx Lp
Operator Street Address
1515 Arapahoe Street Suite 1600
Operator City Name
Denver
Operator State Abbreviation
CO
Operator Postal Code
80202
Time Zone
Mountain
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
0.3
Recovered Bbls
0.3
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Communication State Fed Ind
No
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Notify Qualified Indiv Ind
No
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Cr1
Segment Name
Swg-000020-1
Onshore State Abbreviation
Nm
Onshore Postal Code
88252
Onshore City Name
Not Within A Municipality
Onshore County Name
Lea
Designated Location
Milepost
Designated Name
0+00
Federal
Yes
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pump
Pump Type
Other
Pump Type Details
Centrifical
Pump Service Type
Mainline
Installation Year
2017
Manufactured Year
2015
Material Involved
Material Other Than Carbon Steel
Material Details
Pump Seal Packing
Release Type
Leak
Leak Type
Seal Or Packing
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
0
Est Cost Prop Damage
6800
Est Cost Emergency
0
Est Cost Environmental
0
Est Cost Other
0
Prpty
6800
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
502
Mop Psig
1470
Mop Cfr Section
Internal Design Pressure �195.406(A)(1)
Maop Established Date
2017-07-15 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
Yes
Cpm Conf Ind
Yes
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
It was a mechanical failure.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Pump Or Pump-Related Equipment
Eq Failure Type
Pump Or Pump-Related Equipment
Other Pump Ind
Seal/packing Failure
Eq Additional Other Ind
Yes
Eq Additional Other Details
Pump Seal Failure, Normal Wear
Preparer Name
K**** N*****
Preparer Title
Pipeline Compliance
Preparer Email
W*******@m***.com
Preparer Telephone
15053600834
Prepared Date
2023-10-23 00:00:00
Local Contact Name
A***** I******
Local Contact Email
A*******@m***.com
Local Contact Telephone
4328940462
Authorizer Name
T*** M********
Authorizer Telephone
3034893275
Authorizer Title
Pipeline Compliance Manager
Authorizer Email
T*********@m***.com
Narrative
On 9/22/2023 at 9:00 am (mountain time), an mplx operator was doing a station check and noticed oil on the mainline pump containment. The operator called the controller to shut down pump ml-483 and notified the area supervisor. The supervisor dispatched a hydro-vac to assist with the cleanup of the containment and drain isolated segment on that pump. The pump seal failed recently as the operator had station checks the day before and walked through those pumps multiple times. The spare pump was put into service to avoid any downtime, and pump 483 was repaired and put back into service on 09/26/2023.
Report Received Date 2023-10-23 00:00:00
Iyear 2023
Report Number 20230247
Supplemental Number 38692
Report Type Original Final
Operator Id 40149 PHMSA Enforcement
Name Mplx Lp
Operator Street Address 1515 Arapahoe Street Suite 1600
Operator City Name Denver
Operator State Abbreviation CO
Operator Postal Code 80202
Time Zone Mountain
Daylight Savings Ind Yes
Location Latitude 32.06376 Google Maps OpenStreetMap
Location Longitude -103.67632 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 0.3
Recovered Bbls 0.3
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Operator Employee
System Part Involved Onshore Pump/meter Station Equipment And Piping
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind Yes
Communication State Fed Ind No
Nrc Rpt Num Nrc Notification Not Required NRC Report How to search
Ignite Ind No
Notify Qualified Indiv Ind No
Oil Spill Removal Org Ind No
Num Pub Evacuated 0
Pipe Fac Name Cr1
Segment Name Swg-000020-1
Onshore State Abbreviation Nm
Onshore Postal Code 88252
Onshore City Name Not Within A Municipality
Onshore County Name Lea
Designated Location Milepost
Designated Name 0+00
Federal Yes
Location Type Totally Contained On Operator-Controlled Property
Incident Area Type Aboveground
Incident Area Subtype Typical Aboveground Facility Piping Or Appurtenance
Crossing No
Pipe Facility Type Interstate
Item Involved Pump
Pump Type Other
Pump Type Details Centrifical
Pump Service Type Mainline
Installation Year 2017
Manufactured Year 2015
Material Involved Material Other Than Carbon Steel
Material Details Pump Seal Packing
Release Type Leak
Leak Type Seal Or Packing
Wildlife Impact Ind No
Soil Contamination No
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca No
Commodity Reached Hca No
Est Cost Oper Paid 0
Est Cost Gas Released 0
Est Cost Prop Damage 6800
Est Cost Emergency 0
Est Cost Environmental 0
Est Cost Other 0
Prpty 6800
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 502
Mop Psig 1470
Mop Cfr Section Internal Design Pressure �195.406(A)(1) View CFR 49 §192
Maop Established Date 2017-07-15 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind Yes
Cpm Conf Ind Yes
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details It was a mechanical failure.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Equipment Failure
Cause Details Pump Or Pump-Related Equipment
Eq Failure Type Pump Or Pump-Related Equipment
Other Pump Ind Seal/packing Failure
Eq Additional Other Ind Yes
Eq Additional Other Details Pump Seal Failure, Normal Wear
Preparer Name K**** N*****
Preparer Title Pipeline Compliance
Preparer Email W*******@m***.com
Preparer Telephone 15053600834
Prepared Date 2023-10-23 00:00:00
Local Contact Name A***** I******
Local Contact Email A*******@m***.com
Local Contact Telephone 4328940462
Authorizer Name T*** M********
Authorizer Telephone 3034893275
Authorizer Title Pipeline Compliance Manager
Authorizer Email T*********@m***.com
Narrative On 9/22/2023 at 9:00 am (mountain time), an mplx operator was doing a station check and noticed oil on the mainline pump containment. The operator called the controller to shut down pump ml-483 and notified the area supervisor. The supervisor dispatched a hydro-vac to assist with the cleanup of the containment and drain isolated segment on that pump. The pump seal failed recently as the operator had station checks the day before and walked through those pumps multiple times. The spare pump was put into service to avoid any downtime, and pump 483 was repaired and put back into service on 09/26/2023.

All rights reserved. Copyright © by ClearPHMSA