HL incident on 2023-09-27 — TX

Operator
Inland Corporation
Cause
Corrosion Failure
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$26,000
Incident datetime
2023-09-27 00:00 UTC
Report number
Location
TX
Narrative
On 8/29/2023 at approximately 12:05 et, the control center received a call from a property owner concerning a gasoline odor and dead vegetation near the inland toledo to fostoria tr10 line. Internal notifications were made, and the pipeline was shutdown at 12:24. Control center personnel notified local operations and personnel arrived on site at approximately 12:40. After investigation and excavation the release was confirmed to be from the tr10 pipeline at approximately 15:15. Details were compiled and nrc, PHMSA and ohio epa notifications were made. Approximately 4 barrels of gasoline were released into the soil, which migrated underneath the roadway into a drainage ditch that flows to ayers creek. Field personnel and osros worked to recover free product from soil and water and remove contaminated soil. On 8/30/2023, a plidco mechanical clamp was installed as a temporary repair until the permanent repair can be made. The line was restarted under a temporary pressure reduction until permanent repair was made. On 9/12/2023, the failed section of pipe was cut out, replaced and the temporary operating pressure reduction was removed. The failed section was preserved and shipped to a 3rd party laboratory for analysis to determine failure mechanism. Supplemental report will be filed when analysis has been completed. Supplemental report: the cause of the accident was determined to be external corrosion. The results of the analysis indicate that the leak occurred at an area of external corrosion that contained axially oriented cracking. The cracking mechanism may be associated with corrosion fatigue or near neutral ph scc, or a combination thereof. To prevent reoccurrence line will be assessed with ili technology capable of detecting like and similar features to that of the failure and appropriate remedial steps will be taken based on the results of the run.
Detailed record list
Report Received Date
2023-09-27 00:00:00
Iyear
2023
Report Number
20230229
Supplemental Number
39416
Report Type
Supplemental Final
Operator Id
Name
Inland Corporation
Operator Street Address
1300 Main Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Time Zone
Eastern
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Gasoline (Non-Ethanol)
Unintentional Release Bbls
4
Recovered Bbls
4
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Public
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Nrc Rpt Num
Additional Nrc Report Numbers
1377625 1377770
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Type Ind
Remotely Controlled
Downstream Action Taken
Valve Closure
Downstream Valve Type Ind
Manual
Notify Qualified Indiv Ind
Yes
Oil Spill Removal Org Ind
Yes
Osro Arrived On Site Dt
8/29/2023 14:00
Num Pub Evacuated
0
Pipe Fac Name
Inland Pipeline
Segment Name
13201 Tr10 Toledo-Fostoria 10-Inch
Onshore State Abbreviation
Oh
Onshore Postal Code
43619
Onshore City Name
Northwood
Onshore County Name
Wood
Designated Location
Survey Station No.
Designated Name
35202.7
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
60
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Body
Puddle Weld Ind
No
Pipe Diameter
10
Pipe Wall Thickness
0.25
Pipe Smys
46000
Pipe Specification
X-46
Pipe Seam Type
Seamless
Pipe Manufacturer
Jones And Laughlin Steel Company
Pipe Coating Type
Coal Tar
Coating Applied Ind
Yes
Installation Year
1955
Manufactured Year
1955
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
Yes
Fish Aquatic Impact Ind
Yes
Soil Contamination
Yes
Long Term Assessment
Yes
Remediation Ind
Yes
Surface Water Remed Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
Yes
Surface Contam Ind
Yes
Amount Released
0.12
Rel Water Name
West Side Culvert Ditch, Upstream And Downstream Along Mathews Road
Could Be Hca
Yes
Commodity Reached Hca
No
Est Cost Oper Paid
20000
Est Cost Gas Released
470
Est Cost Prop Damage
26000
Est Cost Emergency
78230
Est Cost Environmental
289170
Est Cost Other
0
Prpty
413870
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
540
Mop Psig
1200
Mop Cfr Section
Subpart E Pressure Test �195.406(A)(3)
Maop Established Date
1969-09-11 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
44352
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
A review of the accident determined that there were no control room actions that contributed to the event.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Galvanic Corrosion Ind
Yes
Metallurgical Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
1955
Shielding Evident
No
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Close Interval Survey Ind
Yes
Cp Annual Survey Year
2021
Close Interval Survey Year
2021
Prior Damage
Yes
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Ultrasonic Ind
Yes
Geometry Deformation Ind
Yes
Axial Recent Year
2022
Axial Rcnt Propul Method
Free Swimming
Axial Rcnt Attuned Detect
Metal Loss
Axial Rcnt Atnd Dtct Metal
High Resolution
Axial Previous Year
2017
Axial Prev Propul Method
Free Swimming
Axial Prev Attuned Detect
Metal Loss
Axial Prev Atnd Dtct Metal
High Resolution
Ultrasonic Recent Year
2012
Ultrasonic Rcnt Propul Method
Free Swimming
Ultrasonic Rcnt Attuned
Crack
Ultr Previous Year
2012
Ultra Prev Propul Method
Free Swimming
Ultra Prev Attuned
Crack
Geometry Recent Year
2022
Geometry Rcnt Propul Method
Free Swimming
Geometry Rcnt Resolution
High Resolution
Geometrt Rcnt Measur Cups
No Cups
Geometry Previous Year
2017
Geometry Prev Propul Method
Free Swimming
Geometry Prev Resolution
High Resolution
Geometrt Prev Measur Cups
No Cups
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
1969
Hydrtst Most Rcnt Pressure
1774
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Pwf Env Stress Corrosion Ind
Yes
Preparer Name
T*** N*******
Preparer Title
Director - Dot Compliance
Preparer Email
T************@e*************.com
Preparer Telephone
713-989-7126
Prepared Date
2024-04-09 00:00:00
Authorizer Name
T*** N*******
Authorizer Telephone
713-989-7126
Authorizer Title
Director - Dot Compliance
Authorizer Email
T************@e*************.com
Narrative
On 8/29/2023 at approximately 12:05 et, the control center received a call from a property owner concerning a gasoline odor and dead vegetation near the inland toledo to fostoria tr10 line. Internal notifications were made, and the pipeline was shutdown at 12:24. Control center personnel notified local operations and personnel arrived on site at approximately 12:40. After investigation and excavation the release was confirmed to be from the tr10 pipeline at approximately 15:15. Details were compiled and nrc, PHMSA and ohio epa notifications were made. Approximately 4 barrels of gasoline were released into the soil, which migrated underneath the roadway into a drainage ditch that flows to ayers creek. Field personnel and osros worked to recover free product from soil and water and remove contaminated soil. On 8/30/2023, a plidco mechanical clamp was installed as a temporary repair until the permanent repair can be made. The line was restarted under a temporary pressure reduction until permanent repair was made. On 9/12/2023, the failed section of pipe was cut out, replaced and the temporary operating pressure reduction was removed. The failed section was preserved and shipped to a 3rd party laboratory for analysis to determine failure mechanism. Supplemental report will be filed when analysis has been completed. Supplemental report: the cause of the accident was determined to be external corrosion. The results of the analysis indicate that the leak occurred at an area of external corrosion that contained axially oriented cracking. The cracking mechanism may be associated with corrosion fatigue or near neutral ph scc, or a combination thereof. To prevent reoccurrence line will be assessed with ili technology capable of detecting like and similar features to that of the failure and appropriate remedial steps will be taken based on the results of the run.
Report Received Date 2023-09-27 00:00:00
Iyear 2023
Report Number 20230229
Supplemental Number 39416
Report Type Supplemental Final
Operator Id 32683 PHMSA Enforcement
Name Inland Corporation
Operator Street Address 1300 Main Street
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77002
Time Zone Eastern
Daylight Savings Ind Yes
Location Latitude 41.57872 Google Maps OpenStreetMap
Location Longitude -83.44446 Google Maps OpenStreetMap
Commodity Released Type Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype Gasoline (Non-Ethanol)
Unintentional Release Bbls 4
Recovered Bbls 4
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Notification From Public
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind Yes
Communication State Fed Ind Yes
Party Initiated Communication Operator
Nrc Rpt Num 1377623 NRC Report How to search
Additional Nrc Report Numbers 1377625 1377770
Ignite Ind No
Upstream Action Taken Valve Closure
Upstream Valve Type Ind Remotely Controlled
Downstream Action Taken Valve Closure
Downstream Valve Type Ind Manual
Notify Qualified Indiv Ind Yes
Oil Spill Removal Org Ind Yes
Osro Arrived On Site Dt 8/29/2023 14:00
Num Pub Evacuated 0
Pipe Fac Name Inland Pipeline
Segment Name 13201 Tr10 Toledo-Fostoria 10-Inch
Onshore State Abbreviation Oh
Onshore Postal Code 43619
Onshore City Name Northwood
Onshore County Name Wood
Designated Location Survey Station No.
Designated Name 35202.7
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 60
Crossing No
Pipe Facility Type Interstate
Item Involved Pipe
Pipe Type Pipe Body
Puddle Weld Ind No
Pipe Diameter 10
Pipe Wall Thickness 0.25
Pipe Smys 46000
Pipe Specification X-46
Pipe Seam Type Seamless
Pipe Manufacturer Jones And Laughlin Steel Company
Pipe Coating Type Coal Tar
Coating Applied Ind Yes
Installation Year 1955
Manufactured Year 1955
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind Yes
Fish Aquatic Impact Ind Yes
Soil Contamination Yes
Long Term Assessment Yes
Remediation Ind Yes
Surface Water Remed Ind Yes
Soil Remed Ind Yes
Water Contam Ind Yes
Surface Contam Ind Yes
Amount Released 0.12
Rel Water Name West Side Culvert Ditch, Upstream And Downstream Along Mathews Road
Could Be Hca Yes
Commodity Reached Hca No
Est Cost Oper Paid 20000
Est Cost Gas Released 470
Est Cost Prop Damage 26000
Est Cost Emergency 78230
Est Cost Environmental 289170
Est Cost Other 0
Prpty 413870
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 540
Mop Psig 1200
Mop Cfr Section Subpart E Pressure Test �195.406(A)(3) View CFR 49 §192
Maop Established Date 1969-09-11 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 44352
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind No
Cpm Conf Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details A review of the accident determined that there were no control room actions that contributed to the event.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details External Corrosion
Internal External External Corrosion
Visual Exam Results Localized Pitting
Galvanic Corrosion Ind Yes
Metallurgical Basis Ind Yes
Underground Location Yes
Under Cathodic Protection Ind Yes
Cathodic Pro Start Year 1955
Shielding Evident No
Cathodic Survey Type Yes
Cp Annual Survey Ind Yes
Close Interval Survey Ind Yes
Cp Annual Survey Year 2021
Close Interval Survey Year 2021
Prior Damage Yes
Collected Data Ind Yes
Axial Magnetic Flx Lkg Ind Yes
Ultrasonic Ind Yes
Geometry Deformation Ind Yes
Axial Recent Year 2022
Axial Rcnt Propul Method Free Swimming
Axial Rcnt Attuned Detect Metal Loss
Axial Rcnt Atnd Dtct Metal High Resolution
Axial Previous Year 2017
Axial Prev Propul Method Free Swimming
Axial Prev Attuned Detect Metal Loss
Axial Prev Atnd Dtct Metal High Resolution
Ultrasonic Recent Year 2012
Ultrasonic Rcnt Propul Method Free Swimming
Ultrasonic Rcnt Attuned Crack
Ultr Previous Year 2012
Ultra Prev Propul Method Free Swimming
Ultra Prev Attuned Crack
Geometry Recent Year 2022
Geometry Rcnt Propul Method Free Swimming
Geometry Rcnt Resolution High Resolution
Geometrt Rcnt Measur Cups No Cups
Geometry Previous Year 2017
Geometry Prev Propul Method Free Swimming
Geometry Prev Resolution High Resolution
Geometrt Prev Measur Cups No Cups
Has Hydrtst Conduc Before Ind Yes
Hydrtst Most Rcnt Year 1969
Hydrtst Most Rcnt Pressure 1774
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Pwf Env Stress Corrosion Ind Yes
Preparer Name T*** N*******
Preparer Title Director - Dot Compliance
Preparer Email T************@e*************.com
Preparer Telephone 713-989-7126
Prepared Date 2024-04-09 00:00:00
Authorizer Name T*** N*******
Authorizer Telephone 713-989-7126
Authorizer Title Director - Dot Compliance
Authorizer Email T************@e*************.com
Narrative On 8/29/2023 at approximately 12:05 et, the control center received a call from a property owner concerning a gasoline odor and dead vegetation near the inland toledo to fostoria tr10 line. Internal notifications were made, and the pipeline was shutdown at 12:24. Control center personnel notified local operations and personnel arrived on site at approximately 12:40. After investigation and excavation the release was confirmed to be from the tr10 pipeline at approximately 15:15. Details were compiled and nrc, PHMSA and ohio epa notifications were made. Approximately 4 barrels of gasoline were released into the soil, which migrated underneath the roadway into a drainage ditch that flows to ayers creek. Field personnel and osros worked to recover free product from soil and water and remove contaminated soil. On 8/30/2023, a plidco mechanical clamp was installed as a temporary repair until the permanent repair can be made. The line was restarted under a temporary pressure reduction until permanent repair was made. On 9/12/2023, the failed section of pipe was cut out, replaced and the temporary operating pressure reduction was removed. The failed section was preserved and shipped to a 3rd party laboratory for analysis to determine failure mechanism. Supplemental report will be filed when analysis has been completed. Supplemental report: the cause of the accident was determined to be external corrosion. The results of the analysis indicate that the leak occurred at an area of external corrosion that contained axially oriented cracking. The cracking mechanism may be associated with corrosion fatigue or near neutral ph scc, or a combination thereof. To prevent reoccurrence line will be assessed with ili technology capable of detecting like and similar features to that of the failure and appropriate remedial steps will be taken based on the results of the run.