HL incident on 2023-09-25 — GA

Operator
Colonial Pipeline Co
Cause
Equipment Failure
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$75
Incident datetime
2023-09-25 00:00 UTC
Report number
Location
GA
Narrative
On 8/28/23 at or around 01:18 cst a field operator ii (foii) conducting routine sampling heard product dripping in the vicinity of the station sample building. The appropriate notifications were made in accordance with procedure. Upon further investigation the foii observed the htn l2 rcv trap door leaking product. The foii instructed the desk operator (foi) to shut down the station (l1 and l2) and proceeded to drain the receiving trap door effectively stopping the leaking product. All released product (51 gallons) was contained on site and recovered. It was discovered that the o-ring in the door had separated in 2 locations causing the release. Repairs were completed and the line was returned to normal operations on 8/28/2023 at approximately 2:26 cst. To mitigate reoccurrence procedural action items will be to replace the o-ring for each time a trap door is opened. No external notifications were required.
Detailed record list
Report Received Date
2023-09-25 00:00:00
Iyear
2023
Report Number
20230224
Supplemental Number
38615
Report Type
Supplemental Final
Operator Id
Name
Colonial Pipeline Co
Operator Street Address
1000 Lake St.
Operator City Name
Alpharetta
Operator State Abbreviation
GA
Operator Postal Code
30009
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
-95.17919497
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Diesel, Fuel Oil, Kerosene, Jet Fuel
Unintentional Release Bbls
1
Recovered Bbls
1
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
System Part Involved
Onshore Terminal/tank Farm Equipment And Piping
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Communication State Fed Ind
No
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Notify Qualified Indiv Ind
No
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Houston Station
Segment Name
2294
Onshore State Abbreviation
Tx
Onshore Postal Code
77506
Onshore City Name
Pasadena
Onshore County Name
Harris
Designated Location
Survey Station No.
Designated Name
120
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Scraper/pig Trap
Installation Year
2023
Manufactured Year
Unknown
Material Involved
Material Other Than Carbon Steel
Material Details
Rubber O-Ring
Release Type
Leak
Leak Type
Seal Or Packing
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
129
Est Cost Prop Damage
75
Est Cost Emergency
1500
Est Cost Environmental
4500
Est Cost Other
0
Prpty
6204
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
95
Mop Psig
275
Mop Cfr Section
Component Design Pressure �195.406(A)(2)
Maop Established Date
2001-10-17 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Equipment failure
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Non-Threaded Connection Failure
Eq Failure Type
Non-Threaded Connection Failure
Other Non Threaded Ind
O-Ring
Eq Additional Other Ind
Yes
Eq Additional Other Details
O-Ring Failed At Point Of Vulcanization
Preparer Name
R***** D*****
Preparer Email
R******@c******.com
Preparer Telephone
4097904288
Prepared Date
2023-10-04 00:00:00
Authorizer Name
Q****** F******
Authorizer Telephone
7706879672
Authorizer Email
Q*******@c******.com
Narrative
On 8/28/23 at or around 01:18 cst a field operator ii (foii) conducting routine sampling heard product dripping in the vicinity of the station sample building. The appropriate notifications were made in accordance with procedure. Upon further investigation the foii observed the htn l2 rcv trap door leaking product. The foii instructed the desk operator (foi) to shut down the station (l1 and l2) and proceeded to drain the receiving trap door effectively stopping the leaking product. All released product (51 gallons) was contained on site and recovered. It was discovered that the o-ring in the door had separated in 2 locations causing the release. Repairs were completed and the line was returned to normal operations on 8/28/2023 at approximately 2:26 cst. To mitigate reoccurrence procedural action items will be to replace the o-ring for each time a trap door is opened. No external notifications were required.
Report Received Date 2023-09-25 00:00:00
Iyear 2023
Report Number 20230224
Supplemental Number 38615
Report Type Supplemental Final
Operator Id 2552 PHMSA Enforcement
Name Colonial Pipeline Co
Operator Street Address 1000 Lake St.
Operator City Name Alpharetta
Operator State Abbreviation GA
Operator Postal Code 30009
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 29.71901833 Google Maps OpenStreetMap
Location Longitude -95.17919497 Google Maps OpenStreetMap
Commodity Released Type Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype Diesel, Fuel Oil, Kerosene, Jet Fuel
Unintentional Release Bbls 1
Recovered Bbls 1
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Operator Employee
System Part Involved Onshore Terminal/tank Farm Equipment And Piping
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind Yes
Communication State Fed Ind No
Nrc Rpt Num Nrc Notification Not Required NRC Report How to search
Ignite Ind No
Notify Qualified Indiv Ind No
Oil Spill Removal Org Ind No
Num Pub Evacuated 0
Pipe Fac Name Houston Station
Segment Name 2294
Onshore State Abbreviation Tx
Onshore Postal Code 77506
Onshore City Name Pasadena
Onshore County Name Harris
Designated Location Survey Station No.
Designated Name 120
Federal No
Location Type Totally Contained On Operator-Controlled Property
Incident Area Type Aboveground
Incident Area Subtype Typical Aboveground Facility Piping Or Appurtenance
Crossing No
Pipe Facility Type Interstate
Item Involved Scraper/pig Trap
Installation Year 2023
Manufactured Year Unknown
Material Involved Material Other Than Carbon Steel
Material Details Rubber O-Ring
Release Type Leak
Leak Type Seal Or Packing
Wildlife Impact Ind No
Soil Contamination No
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca No
Est Cost Oper Paid 0
Est Cost Gas Released 129
Est Cost Prop Damage 75
Est Cost Emergency 1500
Est Cost Environmental 4500
Est Cost Other 0
Prpty 6204
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 95
Mop Psig 275
Mop Cfr Section Component Design Pressure �195.406(A)(2) View CFR 49 §192
Maop Established Date 2001-10-17 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind No
Cpm Conf Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details Equipment failure
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Equipment Failure
Cause Details Non-Threaded Connection Failure
Eq Failure Type Non-Threaded Connection Failure
Other Non Threaded Ind O-Ring
Eq Additional Other Ind Yes
Eq Additional Other Details O-Ring Failed At Point Of Vulcanization
Preparer Name R***** D*****
Preparer Email R******@c******.com
Preparer Telephone 4097904288
Prepared Date 2023-10-04 00:00:00
Authorizer Name Q****** F******
Authorizer Telephone 7706879672
Authorizer Email Q*******@c******.com
Narrative On 8/28/23 at or around 01:18 cst a field operator ii (foii) conducting routine sampling heard product dripping in the vicinity of the station sample building. The appropriate notifications were made in accordance with procedure. Upon further investigation the foii observed the htn l2 rcv trap door leaking product. The foii instructed the desk operator (foi) to shut down the station (l1 and l2) and proceeded to drain the receiving trap door effectively stopping the leaking product. All released product (51 gallons) was contained on site and recovered. It was discovered that the o-ring in the door had separated in 2 locations causing the release. Repairs were completed and the line was returned to normal operations on 8/28/2023 at approximately 2:26 cst. To mitigate reoccurrence procedural action items will be to replace the o-ring for each time a trap door is opened. No external notifications were required.

All rights reserved. Copyright © by ClearPHMSA