HL incident on 2023-08-11 — TX

Operator
Ineos Usa Llc
Cause
Material Failure Of Pipe Or Weld
Commodity
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$6,000,000
Incident datetime
2023-08-11 00:00 UTC
Report number
Location
TX
Narrative
On july 13, 2023, a fire was observed at a valve station on ineos pipeline corridor at persimmon bayou, in brazoria county, tx. Ineos and local emergency personnel responded to the scene, isolated the segment of pipelines, and installed temporary flares to safely dispose of petroleum products entrained in the isolated segments. The fire was largely extinguished by 9:30 p.M. On the same day. The root cause was determined to be crack formation, based on investigation and metallurgical tests of the damaged pipe.
Detailed record list
Report Received Date
2023-08-11 00:00:00
Iyear
2023
Report Number
20230187
Supplemental Number
38674
Report Type
Supplemental Final
Operator Id
Name
Ineos Usa Llc
Operator Street Address
2600 South Shore Blvd, Suite 500
Operator City Name
League City
Operator State Abbreviation
TX
Operator Postal Code
77573
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype
Other Hvl
Commodity Details
Ethylene
Unintentional Release Bbls
3132
Intentional Release Bbls
2912.76
Recovered Bbls
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations)
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Still Shutdown Ind
Yes
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Nrc Rpt Num
Ignite Ind
Yes
How Extinguished
Allowed To Burn Out
Consumed By Fire In Barrels
2912.76
Explode Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Type Ind
Manual
Downstream Action Taken
Valve Closure
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
Ethylene Pipeline System
Segment Name
Ins-Tccb-E
Onshore State Abbreviation
Tx
Onshore Postal Code
77512
Onshore City Name
Not Within A Municipality
Onshore County Name
Brazoria
Designated Location
Survey Station No.
Designated Name
Valve Station
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
72
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Body
Puddle Weld Ind
No
Pipe Diameter
12.75
Pipe Wall Thickness
0.281
Pipe Smys
60000
Pipe Specification
Api 5l X-60 Erw
Pipe Seam Type
Erw - High Frequency
Pipe Manufacturer
Unknown
Pipe Coating Type
Cold Applied Tape
Coating Applied Ind
Yes
Installation Year
1976
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Rupture
Rupture Orient
Longitudinal
Rupture Width
12.7
Rupture Length
24
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
0
Est Cost Gas Released
108752
Est Cost Prop Damage
6000000
Est Cost Emergency
40000
Est Cost Environmental
0
Est Cost Other
0
Prpty
6148752
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
1676
Mop Psig
1902
Mop Cfr Section
Subpart E Pressure Test �195.406(A)(3)
Maop Established Date
1976-02-05 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
15220
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
Yes
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
Yes
Cpm Conf Ind
Yes
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest Schedule Ind
Yes
Invest No Control Room Ind
Yes
Invest No Controller Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Material Failure Of Pipe Or Weld
Cause Details
Environmental Cracking-Related
Metallurgical Ind
Yes
Failure Type
Environmental Cracking-Related
Stress Subtype
Stress Corrosion Cracking
Additional Crack Ind
Yes
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Geometry Deformation Ind
Yes
Axial Recent Year
2021
Axial Rcnt Propul Method
Free Swimming
Axial Rcnt Attuned Detect
Metal Loss
Axial Rcnt Atnd Dtct Metal
High Resolution
Axial Previous Year
2017
Axial Prev Propul Method
Free Swimming
Axial Prev Attuned Detect
Metal Loss
Axial Prev Atnd Dtct Metal
High Resolution
Geometry Recent Year
2021
Geometry Rcnt Propul Method
Free Swimming
Geometry Rcnt Resolution
High Resolution
Geometrt Rcnt Measur Cups
Inside Ili Cups
Geometry Previous Year
2017
Geometry Prev Propul Method
Free Swimming
Geometry Prev Resolution
High Resolution
Geometrt Prev Measur Cups
Inside Ili Cups
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Pwf Env Stress Corrosion Ind
Yes
Preparer Name
M****** B******
Preparer Title
Pso She Manager
Preparer Email
M**************@i****.com
Preparer Telephone
281-581-4404
Prepared Date
2023-10-19 00:00:00
Authorizer Name
R*** O*******
Authorizer Telephone
281-581-3393
Authorizer Title
Pso Manager
Authorizer Email
R***********@i****.com
Narrative
On july 13, 2023, a fire was observed at a valve station on ineos pipeline corridor at persimmon bayou, in brazoria county, tx. Ineos and local emergency personnel responded to the scene, isolated the segment of pipelines, and installed temporary flares to safely dispose of petroleum products entrained in the isolated segments. The fire was largely extinguished by 9:30 p.M. On the same day. The root cause was determined to be crack formation, based on investigation and metallurgical tests of the damaged pipe.
Report Received Date 2023-08-11 00:00:00
Iyear 2023
Report Number 20230187
Supplemental Number 38674
Report Type Supplemental Final
Operator Id 39398 PHMSA Enforcement
Name Ineos Usa Llc
Operator Street Address 2600 South Shore Blvd, Suite 500
Operator City Name League City
Operator State Abbreviation TX
Operator Postal Code 77573
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 29.25754 Google Maps OpenStreetMap
Location Longitude -95.137019 Google Maps OpenStreetMap
Commodity Released Type Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype Other Hvl
Commodity Details Ethylene
Unintentional Release Bbls 3132
Intentional Release Bbls 2912.76
Recovered Bbls 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations)
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind Yes
Still Shutdown Ind Yes
Communication State Fed Ind Yes
Party Initiated Communication Operator
Nrc Rpt Num 1372979 NRC Report How to search
Ignite Ind Yes
How Extinguished Allowed To Burn Out
Consumed By Fire In Barrels 2912.76
Explode Ind No
Upstream Action Taken Valve Closure
Upstream Valve Type Ind Manual
Downstream Action Taken Valve Closure
Downstream Valve Type Ind Manual
Num Pub Evacuated 0
Pipe Fac Name Ethylene Pipeline System
Segment Name Ins-Tccb-E
Onshore State Abbreviation Tx
Onshore Postal Code 77512
Onshore City Name Not Within A Municipality
Onshore County Name Brazoria
Designated Location Survey Station No.
Designated Name Valve Station
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 72
Crossing No
Pipe Facility Type Intrastate
Item Involved Pipe
Pipe Type Pipe Body
Puddle Weld Ind No
Pipe Diameter 12.75
Pipe Wall Thickness 0.281
Pipe Smys 60000
Pipe Specification Api 5l X-60 Erw
Pipe Seam Type Erw - High Frequency
Pipe Manufacturer Unknown
Pipe Coating Type Cold Applied Tape
Coating Applied Ind Yes
Installation Year 1976
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Rupture
Rupture Orient Longitudinal
Rupture Width 12.7
Rupture Length 24
Wildlife Impact Ind No
Soil Contamination No
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca No
Commodity Reached Hca No
Est Cost Oper Paid 0
Est Cost Gas Released 108752
Est Cost Prop Damage 6000000
Est Cost Emergency 40000
Est Cost Environmental 0
Est Cost Other 0
Prpty 6148752
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 1676
Mop Psig 1902
Mop Cfr Section Subpart E Pressure Test �195.406(A)(3) View CFR 49 §192
Maop Established Date 1976-02-05 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 15220
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind Yes
Scada Conf Ind Yes
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind Yes
Cpm Conf Ind Yes
Investigation Status Yes, specify investigation result(s): (select all that apply)
Invest Schedule Ind Yes
Invest No Control Room Ind Yes
Invest No Controller Ind Yes
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Material Failure Of Pipe Or Weld
Cause Details Environmental Cracking-Related
Metallurgical Ind Yes
Failure Type Environmental Cracking-Related
Stress Subtype Stress Corrosion Cracking
Additional Crack Ind Yes
Collected Data Ind Yes
Axial Magnetic Flx Lkg Ind Yes
Geometry Deformation Ind Yes
Axial Recent Year 2021
Axial Rcnt Propul Method Free Swimming
Axial Rcnt Attuned Detect Metal Loss
Axial Rcnt Atnd Dtct Metal High Resolution
Axial Previous Year 2017
Axial Prev Propul Method Free Swimming
Axial Prev Attuned Detect Metal Loss
Axial Prev Atnd Dtct Metal High Resolution
Geometry Recent Year 2021
Geometry Rcnt Propul Method Free Swimming
Geometry Rcnt Resolution High Resolution
Geometrt Rcnt Measur Cups Inside Ili Cups
Geometry Previous Year 2017
Geometry Prev Propul Method Free Swimming
Geometry Prev Resolution High Resolution
Geometrt Prev Measur Cups Inside Ili Cups
Has Hydrtst Conduc Before Ind No
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Pwf Env Stress Corrosion Ind Yes
Preparer Name M****** B******
Preparer Title Pso She Manager
Preparer Email M**************@i****.com
Preparer Telephone 281-581-4404
Prepared Date 2023-10-19 00:00:00
Authorizer Name R*** O*******
Authorizer Telephone 281-581-3393
Authorizer Title Pso Manager
Authorizer Email R***********@i****.com
Narrative On july 13, 2023, a fire was observed at a valve station on ineos pipeline corridor at persimmon bayou, in brazoria county, tx. Ineos and local emergency personnel responded to the scene, isolated the segment of pipelines, and installed temporary flares to safely dispose of petroleum products entrained in the isolated segments. The fire was largely extinguished by 9:30 p.M. On the same day. The root cause was determined to be crack formation, based on investigation and metallurgical tests of the damaged pipe.

All rights reserved. Copyright © by ClearPHMSA