Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2023-07-07 — TX
Operator
Express Holdings (Usa), Llc
Cause
Equipment Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$6,000
Incident datetime
2023-07-07 00:00 UTC
Report number
Location
TX
Narrative
On june 7, 2023, at approximately 8:07 am mdt a third-party pipeline operator reported a release from the delivery end of the frontier lateral at their facility. The edmonton control center immediately shut down the line out of caution and an enbridge technician was sent out to investigate the facility. The technician arrived onsite and at 8:23 am mdt confirmed that there was a release of approximately 1 to 3 barrels that originated in the sample building and migrated out of the building and onto the gravel. The area supervisor arrived on site at 9:10 am mdt and calculated the release to be 8 barrels and determined that cleanup would be more extensive than originally thought exceeding the nrc reporting threshold. The nrc was notified on june 7, 2023, at 9:47 am mdt (nrc# 1369372). The source of the release was identified as a sample canister that overfilled. Additional resources were called in to assist with the release cleanup. Operations removed the sampler to investigate the cause of the release. While rebuilding the sampler, they discovered that the motor of the sampler, that pulses to allow for a small quantity of volume to be collected for sample, was not functioning properly. It was determined that the sampler failed in the open position, creating an open flow path from the sampler to the sample container. The container eventually filled to max capacity and released. The sampling containers are connected to the sump in case of an overfill event, but they could not keep up with the volume coming into the container. A new motor was put in the sampler and the lateral was returned to service. A 48-hour update to the nrc was made on june 9, 2023, at 7:51 am mdt (nrc# 1369555). All product was cleaned up and contaminated soil was removed from the release site and properly disposed of.
Detailed record list
Report Received Date
2023-07-07 00:00:00
Iyear
2023
Report Number
20230148
Supplemental Number
38250
Report Type
Original Final
Operator Id
31720
Name
Express Holdings (Usa), Llc
Operator Street Address
915 N Eldridge Parkway, Suite 1100
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77079
Time Zone
Mountain
Daylight Savings Ind
Yes
Location Latitude
42.85205
Location Longitude
-106.357027
Commodity Released Type
Crude Oil
Unintentional Release Bbls
8
Recovered Bbls
8
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Other
Accident Details
Third Party Operator
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Communication State Fed Ind
No
Nrc Rpt Num
1369372
Additional Nrc Report Numbers
1369555
Ignite Ind
No
Notify Qualified Indiv Ind
Yes
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Frontier Lateral
Segment Name
Sampler
Onshore State Abbreviation
Wy
Onshore Postal Code
82604
Onshore City Name
Casper
Onshore County Name
Natrona
Designated Location
Survey Station No.
Designated Name
Frontier
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Inside A Building
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Instrumentation
Installation Year
Unknown
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Overfill Or Overflow
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Other Pop Ind
Yes
Other Pop Yes No
Yes
Usa Drinking Ind
Yes
Usa Drinking Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
616
Est Cost Prop Damage
6000
Est Cost Emergency
186365
Est Cost Environmental
55000
Est Cost Other
0
Prpty
247981
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
121
Mop Psig
285
Mop Cfr Section
Internal Design Pressure �195.406(A)(1)
Maop Established Date
2005-08-06 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest No Control Room Ind
Yes
Invest No Controller Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Other Equipment Failure
Eq Failure Type
Other Equipment Failure
Failure Details
Sampler Motor
Eq Additional Other Ind
Yes
Eq Additional Other Details
Age Of Asset
Preparer Name
S**** S****
Preparer Title
Advisor Regulatory Compliance
Preparer Email
S**********@e*******.com
Preparer Telephone
7153953620
Prepared Date
2023-07-07 00:00:00
Authorizer Name
L*** S**********
Authorizer Telephone
7153941584
Authorizer Title
Supervisor Regulatory Affairs Compliance
Authorizer Email
L***************@e*******.com
Narrative
On june 7, 2023, at approximately 8:07 am mdt a third-party pipeline operator reported a release from the delivery end of the frontier lateral at their facility. The edmonton control center immediately shut down the line out of caution and an enbridge technician was sent out to investigate the facility. The technician arrived onsite and at 8:23 am mdt confirmed that there was a release of approximately 1 to 3 barrels that originated in the sample building and migrated out of the building and onto the gravel. The area supervisor arrived on site at 9:10 am mdt and calculated the release to be 8 barrels and determined that cleanup would be more extensive than originally thought exceeding the nrc reporting threshold. The nrc was notified on june 7, 2023, at 9:47 am mdt (nrc# 1369372). The source of the release was identified as a sample canister that overfilled. Additional resources were called in to assist with the release cleanup. Operations removed the sampler to investigate the cause of the release. While rebuilding the sampler, they discovered that the motor of the sampler, that pulses to allow for a small quantity of volume to be collected for sample, was not functioning properly. It was determined that the sampler failed in the open position, creating an open flow path from the sampler to the sample container. The container eventually filled to max capacity and released. The sampling containers are connected to the sump in case of an overfill event, but they could not keep up with the volume coming into the container. A new motor was put in the sampler and the lateral was returned to service. A 48-hour update to the nrc was made on june 9, 2023, at 7:51 am mdt (nrc# 1369555). All product was cleaned up and contaminated soil was removed from the release site and properly disposed of.
Report Received Date | 2023-07-07 00:00:00 |
---|---|
Iyear | 2023 |
Report Number | 20230148 |
Supplemental Number | 38250 |
Report Type | Original Final |
Operator Id | 31720 PHMSA Enforcement |
Name | Express Holdings (Usa), Llc |
Operator Street Address | 915 N Eldridge Parkway, Suite 1100 |
Operator City Name | Houston |
Operator State Abbreviation | TX |
Operator Postal Code | 77079 |
Time Zone | Mountain |
Daylight Savings Ind | Yes |
Location Latitude | 42.85205 Google Maps OpenStreetMap |
Location Longitude | -106.357027 Google Maps OpenStreetMap |
Commodity Released Type | Crude Oil |
Unintentional Release Bbls | 8 |
Recovered Bbls | 8 |
Fatality Ind | No |
Fatal | 0 |
Injury Ind | No |
Injure | 0 |
Accident Identifier | Other |
Accident Details | Third Party Operator |
System Part Involved | Onshore Pump/meter Station Equipment And Piping |
On Off Shore | Onshore |
Status When Identified | Normal Operation, Includes Pauses Between Batches And During Maintenance |
Shutdown Due Accident Ind | Yes |
Communication State Fed Ind | No |
Nrc Rpt Num | 1369372 NRC Report How to search |
Additional Nrc Report Numbers | 1369555 |
Ignite Ind | No |
Notify Qualified Indiv Ind | Yes |
Oil Spill Removal Org Ind | No |
Num Pub Evacuated | 0 |
Pipe Fac Name | Frontier Lateral |
Segment Name | Sampler |
Onshore State Abbreviation | Wy |
Onshore Postal Code | 82604 |
Onshore City Name | Casper |
Onshore County Name | Natrona |
Designated Location | Survey Station No. |
Designated Name | Frontier |
Federal | No |
Location Type | Totally Contained On Operator-Controlled Property |
Incident Area Type | Aboveground |
Incident Area Subtype | Inside A Building |
Crossing | No |
Pipe Facility Type | Interstate |
Item Involved | Instrumentation |
Installation Year | Unknown |
Manufactured Year | Unknown |
Material Involved | Carbon Steel |
Release Type | Overfill Or Overflow |
Wildlife Impact Ind | No |
Soil Contamination | Yes |
Long Term Assessment | No |
Remediation Ind | No |
Water Contam Ind | No |
Could Be Hca | Yes |
Commodity Reached Hca | Yes |
High Pop Ind | Yes |
High Pop Yes No | Yes |
Other Pop Ind | Yes |
Other Pop Yes No | Yes |
Usa Drinking Ind | Yes |
Usa Drinking Yes No | Yes |
Est Cost Oper Paid | 0 |
Est Cost Gas Released | 616 |
Est Cost Prop Damage | 6000 |
Est Cost Emergency | 186365 |
Est Cost Environmental | 55000 |
Est Cost Other | 0 |
Prpty | 247981 |
Num Persons Hosp Not Ovnght | 0 |
Num Injured Treated By Emt | 0 |
Num Resident Building Affctd | 0 |
Num Business Building Affctd | 0 |
Accident Psig | 121 |
Mop Psig | 285 |
Mop Cfr Section | Internal Design Pressure �195.406(A)(1) View CFR 49 §192 |
Maop Established Date | 2005-08-06 00:00:00 |
Maop Reversal Flow Ind | No |
Accident Pressure | Pressure Did Not Exceed Mop |
Pressure Restriction Ind | No |
Pipeline Function | > 20% Smys Regulated Transmission |
Scada In Place Ind | Yes |
Scada Operating Ind | Yes |
Scada Functional Ind | Yes |
Scada Detection Ind | No |
Scada Conf Ind | No |
Cpm In Place Ind | No |
Investigation Status | Yes, specify investigation result(s): (select all that apply) |
Invest No Control Room Ind | Yes |
Invest No Controller Ind | Yes |
Employee Drug Test Ind | No |
Contractor Drug Test Ind | No |
Cause | Equipment Failure |
Cause Details | Other Equipment Failure |
Eq Failure Type | Other Equipment Failure |
Failure Details | Sampler Motor |
Eq Additional Other Ind | Yes |
Eq Additional Other Details | Age Of Asset |
Preparer Name | S**** S**** |
Preparer Title | Advisor Regulatory Compliance |
Preparer Email | S**********@e*******.com |
Preparer Telephone | 7153953620 |
Prepared Date | 2023-07-07 00:00:00 |
Authorizer Name | L*** S********** |
Authorizer Telephone | 7153941584 |
Authorizer Title | Supervisor Regulatory Affairs Compliance |
Authorizer Email | L***************@e*******.com |
Narrative | On june 7, 2023, at approximately 8:07 am mdt a third-party pipeline operator reported a release from the delivery end of the frontier lateral at their facility. The edmonton control center immediately shut down the line out of caution and an enbridge technician was sent out to investigate the facility. The technician arrived onsite and at 8:23 am mdt confirmed that there was a release of approximately 1 to 3 barrels that originated in the sample building and migrated out of the building and onto the gravel. The area supervisor arrived on site at 9:10 am mdt and calculated the release to be 8 barrels and determined that cleanup would be more extensive than originally thought exceeding the nrc reporting threshold. The nrc was notified on june 7, 2023, at 9:47 am mdt (nrc# 1369372). The source of the release was identified as a sample canister that overfilled. Additional resources were called in to assist with the release cleanup. Operations removed the sampler to investigate the cause of the release. While rebuilding the sampler, they discovered that the motor of the sampler, that pulses to allow for a small quantity of volume to be collected for sample, was not functioning properly. It was determined that the sampler failed in the open position, creating an open flow path from the sampler to the sample container. The container eventually filled to max capacity and released. The sampling containers are connected to the sump in case of an overfill event, but they could not keep up with the volume coming into the container. A new motor was put in the sampler and the lateral was returned to service. A 48-hour update to the nrc was made on june 9, 2023, at 7:51 am mdt (nrc# 1369555). All product was cleaned up and contaminated soil was removed from the release site and properly disposed of. |