Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2023-07-06 — OK
Operator
Explorer Pipeline Co
Cause
Equipment Failure
Commodity
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$150
Incident datetime
2023-07-06 00:00 UTC
Report number
Location
OK
Narrative
On friday june 9, 2023, at 19:34 cst an explorer pipeline right of way specialist received a call directly from a landowner familiar with explorer personnel regarding a petroleum products odor around mile post 307 on the 28-inch pasadena, texas to greenville, texas line segment. Explorer personnel immediately notified the control center for a pipeline shutdown, and personnel were dispatched to mp 307. Explorer has a properly fenced outstation concrete vault equipped with a gravitometer and pipeline sphere detector called a pig sig. A pig sig is a component that is threaded into a tor and is utilized to send a notification when tripped that a cleaning pig or pipeline sphere is a predetermined volume upstream of the greenville tank farm. Five barrels of refined petroleum product were confirmed inside the concrete vault, and no product had been released outside the vault or off the fenced facility. The pig sig was submitted to the manufacturer who confirmed a failed viton o-ring inside the pig sig was the source of the release.
Detailed record list
Report Received Date
2023-07-06 00:00:00
Iyear
2023
Report Number
20230147
Supplemental Number
38787
Report Type
Supplemental Final
Operator Id
4805
Name
Explorer Pipeline Co
Operator Street Address
Po Box 2650
Operator City Name
Tulsa
Operator State Abbreviation
OK
Operator Postal Code
74101
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
32.983557
Location Longitude
-96.191194
Commodity Released Type
Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions
Commodity Subtype
Gasoline (Non-Ethanol)
Unintentional Release Bbls
5
Recovered Bbls
5
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Public
System Part Involved
Onshore Pump/meter Station Equipment And Piping
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
No
Shutdown Explain
Event Was During Normal Operation And Steady State.
Communication State Fed Ind
No
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Notify Qualified Indiv Ind
Yes
Oil Spill Removal Org Ind
Yes
Osro Arrived On Site Dt
6/9/2023 23:00
Num Pub Evacuated
0
Pipe Fac Name
Pasadena To Greenville
Segment Name
Pasadena To Greenville
Onshore State Abbreviation
Tx
Onshore Postal Code
75135
Onshore City Name
Caddo Mills
Onshore County Name
Hunt
Designated Location
Milepost
Designated Name
307
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Underground
Incident Area Subtype
In Underground Enclosed Space (E.g. Vault)
Depth Of Cover
42
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Tap Fitting(Stopple, Thread-O-Ring, Weld-O-Let, Etc.)
Installation Year
Unknown
Manufactured Year
Unknown
Material Involved
Material Other Than Carbon Steel
Material Details
Viton
Release Type
Leak
Leak Type
Seal Or Packing
Wildlife Impact Ind
No
Soil Contamination
No
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
Other Pop Ind
Yes
Other Pop Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
420
Est Cost Prop Damage
150
Est Cost Emergency
2000
Est Cost Environmental
0
Est Cost Other
0
Prpty
2570
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
45
Mop Psig
751
Mop Cfr Section
Component Design Pressure �195.406(A)(2)
Maop Established Date
1971-01-21 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The controllers actions or inactions did not cause or contribute to the event.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Threaded Connection/coupling Failure
Eq Failure Type
Threaded Connection/coupling Failure
Other Stripped Ind
Threaded Fitting
Eq Additional Other Ind
Yes
Eq Additional Other Details
Seal From Threaded Fitting.
Preparer Name
K**** B****
Preparer Title
Manager Dot And Regulatory Compliance
Preparer Email
K*****@e***.com
Preparer Telephone
918-493-5104
Prepared Date
2023-11-10 00:00:00
Local Contact Name
C***** D*****
Local Contact Email
C******@e***.com
Local Contact Telephone
918-591-3142
Authorizer Name
L***** S******
Authorizer Telephone
918-359-5471
Authorizer Title
Vice President Hsse
Authorizer Email
L*******@e***.com
Narrative
On friday june 9, 2023, at 19:34 cst an explorer pipeline right of way specialist received a call directly from a landowner familiar with explorer personnel regarding a petroleum products odor around mile post 307 on the 28-inch pasadena, texas to greenville, texas line segment. Explorer personnel immediately notified the control center for a pipeline shutdown, and personnel were dispatched to mp 307. Explorer has a properly fenced outstation concrete vault equipped with a gravitometer and pipeline sphere detector called a pig sig. A pig sig is a component that is threaded into a tor and is utilized to send a notification when tripped that a cleaning pig or pipeline sphere is a predetermined volume upstream of the greenville tank farm. Five barrels of refined petroleum product were confirmed inside the concrete vault, and no product had been released outside the vault or off the fenced facility. The pig sig was submitted to the manufacturer who confirmed a failed viton o-ring inside the pig sig was the source of the release.
Report Received Date | 2023-07-06 00:00:00 |
---|---|
Iyear | 2023 |
Report Number | 20230147 |
Supplemental Number | 38787 |
Report Type | Supplemental Final |
Operator Id | 4805 PHMSA Enforcement |
Name | Explorer Pipeline Co |
Operator Street Address | Po Box 2650 |
Operator City Name | Tulsa |
Operator State Abbreviation | OK |
Operator Postal Code | 74101 |
Time Zone | Central |
Daylight Savings Ind | Yes |
Location Latitude | 32.983557 Google Maps OpenStreetMap |
Location Longitude | -96.191194 Google Maps OpenStreetMap |
Commodity Released Type | Refined And/or Petroleum Product (Non-Hvl) Which Is A Liquid At Ambient Conditions |
Commodity Subtype | Gasoline (Non-Ethanol) |
Unintentional Release Bbls | 5 |
Recovered Bbls | 5 |
Fatality Ind | No |
Fatal | 0 |
Injury Ind | No |
Injure | 0 |
Accident Identifier | Notification From Public |
System Part Involved | Onshore Pump/meter Station Equipment And Piping |
On Off Shore | Onshore |
Status When Identified | Normal Operation, Includes Pauses Between Batches And During Maintenance |
Shutdown Due Accident Ind | No |
Shutdown Explain | Event Was During Normal Operation And Steady State. |
Communication State Fed Ind | No |
Nrc Rpt Num | Nrc Notification Not Required NRC Report How to search |
Ignite Ind | No |
Notify Qualified Indiv Ind | Yes |
Oil Spill Removal Org Ind | Yes |
Osro Arrived On Site Dt | 6/9/2023 23:00 |
Num Pub Evacuated | 0 |
Pipe Fac Name | Pasadena To Greenville |
Segment Name | Pasadena To Greenville |
Onshore State Abbreviation | Tx |
Onshore Postal Code | 75135 |
Onshore City Name | Caddo Mills |
Onshore County Name | Hunt |
Designated Location | Milepost |
Designated Name | 307 |
Federal | No |
Location Type | Totally Contained On Operator-Controlled Property |
Incident Area Type | Underground |
Incident Area Subtype | In Underground Enclosed Space (E.g. Vault) |
Depth Of Cover | 42 |
Crossing | No |
Pipe Facility Type | Interstate |
Item Involved | Tap Fitting(Stopple, Thread-O-Ring, Weld-O-Let, Etc.) |
Installation Year | Unknown |
Manufactured Year | Unknown |
Material Involved | Material Other Than Carbon Steel |
Material Details | Viton |
Release Type | Leak |
Leak Type | Seal Or Packing |
Wildlife Impact Ind | No |
Soil Contamination | No |
Long Term Assessment | No |
Remediation Ind | No |
Water Contam Ind | No |
Could Be Hca | Yes |
Commodity Reached Hca | Yes |
Other Pop Ind | Yes |
Other Pop Yes No | Yes |
Est Cost Oper Paid | 0 |
Est Cost Gas Released | 420 |
Est Cost Prop Damage | 150 |
Est Cost Emergency | 2000 |
Est Cost Environmental | 0 |
Est Cost Other | 0 |
Prpty | 2570 |
Num Persons Hosp Not Ovnght | 0 |
Num Injured Treated By Emt | 0 |
Num Resident Building Affctd | 0 |
Num Business Building Affctd | 0 |
Accident Psig | 45 |
Mop Psig | 751 |
Mop Cfr Section | Component Design Pressure �195.406(A)(2) View CFR 49 §192 |
Maop Established Date | 1971-01-21 00:00:00 |
Maop Reversal Flow Ind | No |
Accident Pressure | Pressure Did Not Exceed Mop |
Pressure Restriction Ind | No |
Pipeline Function | > 20% Smys Regulated Transmission |
Scada In Place Ind | Yes |
Scada Operating Ind | Yes |
Scada Functional Ind | Yes |
Scada Detection Ind | No |
Scada Conf Ind | No |
Cpm In Place Ind | Yes |
Cpm Operating Ind | Yes |
Cpm Functional Ind | Yes |
Cpm Detection Ind | No |
Cpm Conf Ind | No |
Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
Investigation Status Details | The controllers actions or inactions did not cause or contribute to the event. |
Employee Drug Test Ind | No |
Contractor Drug Test Ind | No |
Cause | Equipment Failure |
Cause Details | Threaded Connection/coupling Failure |
Eq Failure Type | Threaded Connection/coupling Failure |
Other Stripped Ind | Threaded Fitting |
Eq Additional Other Ind | Yes |
Eq Additional Other Details | Seal From Threaded Fitting. |
Preparer Name | K**** B**** |
Preparer Title | Manager Dot And Regulatory Compliance |
Preparer Email | K*****@e***.com |
Preparer Telephone | 918-493-5104 |
Prepared Date | 2023-11-10 00:00:00 |
Local Contact Name | C***** D***** |
Local Contact Email | C******@e***.com |
Local Contact Telephone | 918-591-3142 |
Authorizer Name | L***** S****** |
Authorizer Telephone | 918-359-5471 |
Authorizer Title | Vice President Hsse |
Authorizer Email | L*******@e***.com |
Narrative | On friday june 9, 2023, at 19:34 cst an explorer pipeline right of way specialist received a call directly from a landowner familiar with explorer personnel regarding a petroleum products odor around mile post 307 on the 28-inch pasadena, texas to greenville, texas line segment. Explorer personnel immediately notified the control center for a pipeline shutdown, and personnel were dispatched to mp 307. Explorer has a properly fenced outstation concrete vault equipped with a gravitometer and pipeline sphere detector called a pig sig. A pig sig is a component that is threaded into a tor and is utilized to send a notification when tripped that a cleaning pig or pipeline sphere is a predetermined volume upstream of the greenville tank farm. Five barrels of refined petroleum product were confirmed inside the concrete vault, and no product had been released outside the vault or off the fenced facility. The pig sig was submitted to the manufacturer who confirmed a failed viton o-ring inside the pig sig was the source of the release. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA