HL incident on 2023-06-23 — TX

Operator
Phillips 66 Pipeline Llc
Cause
Equipment Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$6,500
Incident datetime
2023-06-23 00:00 UTC
Report number
Location
TX
Narrative
During routine operator rounds, company personnel discovered a release from a pump seal on a regulated pump. The pump was not running at the time of the discovery and therefore the release was contained within the pump basin and surrounding area. All product was contained on operator-controlled property. After discovery, the operator who discovered the release notified all necessary company personnel and supervision. On-site contractors and company personnel immediately initiated clean-up/remediation activities. After a failure analysis was performed it was determined that the failure was caused by abnormal wear due to frequent startup and shut down cycles. This is a multi-use pump that is not dedicated to DOT operations.
Detailed record list
Report Received Date
2023-06-23 00:00:00
Iyear
2023
Report Number
20230136
Supplemental Number
38244
Report Type
Supplemental Final
Operator Id
Name
Phillips 66 Pipeline Llc
Operator Street Address
2331 Citywest Blvd
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77042
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
6
Recovered Bbls
6
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Ground Patrol By Operator Or Its Contractor
Operator Type
Operator Employee
System Part Involved
Onshore Terminal/tank Farm Equipment And Piping
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
No
Shutdown Explain
Line Was Not Active At The Time Of The Incident.
Communication State Fed Ind
No
Nrc Rpt Num
Additional Nrc Report Numbers
1368395
Ignite Ind
No
Notify Qualified Indiv Ind
Yes
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
P66 Beaumont Terminal
Segment Name
Pump 4510
Onshore State Abbreviation
Tx
Onshore Postal Code
77627
Onshore City Name
Nederland
Onshore County Name
Jefferson
Designated Location
Survey Station No.
Designated Name
Bmt - 4510
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pump
Pump Type
Centrifugal
Pump Service Type
Other
Pump Service Type Details
Terminal Pump
Installation Year
Unknown
Manufactured Year
Unknown
Material Involved
Material Other Than Carbon Steel
Material Details
Silicon Carbide/stainless Steel/carbon
Release Type
Leak
Leak Type
Seal Or Packing
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
High Pop Ind
Yes
High Pop Yes No
Yes
Est Cost Oper Paid
0
Est Cost Gas Released
420
Est Cost Prop Damage
6500
Est Cost Emergency
4300
Est Cost Environmental
4000
Est Cost Other
0
Prpty
15220
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
188
Mop Psig
720
Mop Cfr Section
Internal Design Pressure �195.406(A)(1)
Maop Established Date
2016-12-25 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Control room operator were not involved with the release..
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Pump Or Pump-Related Equipment
Eq Failure Type
Pump Or Pump-Related Equipment
Other Pump Ind
Seal/packing Failure
Additional Erosion Wear Ind
Yes
Preparer Name
M****** B*********
Preparer Title
Dot Coordinator
Preparer Email
M*******************@p**.com
Preparer Telephone
7134122371
Prepared Date
2023-07-06 00:00:00
Local Contact Name
M****** B*********
Local Contact Email
M*******************@p**.com
Local Contact Telephone
7134122371
Authorizer Name
T*** F****
Authorizer Telephone
8327651632
Authorizer Title
Director Of Dot Operations And Compliance
Authorizer Email
T***********@p**.com
Narrative
During routine operator rounds, company personnel discovered a release from a pump seal on a regulated pump. The pump was not running at the time of the discovery and therefore the release was contained within the pump basin and surrounding area. All product was contained on operator-controlled property. After discovery, the operator who discovered the release notified all necessary company personnel and supervision. On-site contractors and company personnel immediately initiated clean-up/remediation activities. After a failure analysis was performed it was determined that the failure was caused by abnormal wear due to frequent startup and shut down cycles. This is a multi-use pump that is not dedicated to DOT operations.
Report Received Date 2023-06-23 00:00:00
Iyear 2023
Report Number 20230136
Supplemental Number 38244
Report Type Supplemental Final
Operator Id 31684 PHMSA Enforcement
Name Phillips 66 Pipeline Llc
Operator Street Address 2331 Citywest Blvd
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77042
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 29.991722 Google Maps OpenStreetMap
Location Longitude -93.986597 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 6
Recovered Bbls 6
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Ground Patrol By Operator Or Its Contractor
Operator Type Operator Employee
System Part Involved Onshore Terminal/tank Farm Equipment And Piping
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind No
Shutdown Explain Line Was Not Active At The Time Of The Incident.
Communication State Fed Ind No
Nrc Rpt Num 1368366 NRC Report How to search
Additional Nrc Report Numbers 1368395
Ignite Ind No
Notify Qualified Indiv Ind Yes
Oil Spill Removal Org Ind No
Num Pub Evacuated 0
Pipe Fac Name P66 Beaumont Terminal
Segment Name Pump 4510
Onshore State Abbreviation Tx
Onshore Postal Code 77627
Onshore City Name Nederland
Onshore County Name Jefferson
Designated Location Survey Station No.
Designated Name Bmt - 4510
Federal No
Location Type Totally Contained On Operator-Controlled Property
Incident Area Type Aboveground
Incident Area Subtype Typical Aboveground Facility Piping Or Appurtenance
Crossing No
Pipe Facility Type Interstate
Item Involved Pump
Pump Type Centrifugal
Pump Service Type Other
Pump Service Type Details Terminal Pump
Installation Year Unknown
Manufactured Year Unknown
Material Involved Material Other Than Carbon Steel
Material Details Silicon Carbide/stainless Steel/carbon
Release Type Leak
Leak Type Seal Or Packing
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca Yes
High Pop Ind Yes
High Pop Yes No Yes
Est Cost Oper Paid 0
Est Cost Gas Released 420
Est Cost Prop Damage 6500
Est Cost Emergency 4300
Est Cost Environmental 4000
Est Cost Other 0
Prpty 15220
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 188
Mop Psig 720
Mop Cfr Section Internal Design Pressure �195.406(A)(1) View CFR 49 §192
Maop Established Date 2016-12-25 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details Control room operator were not involved with the release..
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Equipment Failure
Cause Details Pump Or Pump-Related Equipment
Eq Failure Type Pump Or Pump-Related Equipment
Other Pump Ind Seal/packing Failure
Additional Erosion Wear Ind Yes
Preparer Name M****** B*********
Preparer Title Dot Coordinator
Preparer Email M*******************@p**.com
Preparer Telephone 7134122371
Prepared Date 2023-07-06 00:00:00
Local Contact Name M****** B*********
Local Contact Email M*******************@p**.com
Local Contact Telephone 7134122371
Authorizer Name T*** F****
Authorizer Telephone 8327651632
Authorizer Title Director Of Dot Operations And Compliance
Authorizer Email T***********@p**.com
Narrative During routine operator rounds, company personnel discovered a release from a pump seal on a regulated pump. The pump was not running at the time of the discovery and therefore the release was contained within the pump basin and surrounding area. All product was contained on operator-controlled property. After discovery, the operator who discovered the release notified all necessary company personnel and supervision. On-site contractors and company personnel immediately initiated clean-up/remediation activities. After a failure analysis was performed it was determined that the failure was caused by abnormal wear due to frequent startup and shut down cycles. This is a multi-use pump that is not dedicated to DOT operations.

All rights reserved. Copyright © by ClearPHMSA