GTG incident on 2023-12-22 — TX

Operator
Kinder Morgan Texas Pipeline Co
Cause
Material Failure Of Pipe Or Weld
Commodity
Natural Gas
Program
GTG
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$30,000
Incident datetime
2023-12-22 00:00 UTC
Report number
Location
TX
Narrative
Reportable gas release occurred on november 25, 2023 with a discovery at 17:20. Personnel was onsite prior to the discovery. Php expansion - php mccamey cs upton county texas. Metallurgical and field analysis confirmed release caused by 2 inch pipe breaking completely off the carrier pipe. Natural gas was released into the air - 4018.1 mcf. The area was evacuated and supervision was called. Operations supervision initiated the internal and external notification. The gas did not ignite. The event was reported to the nrc and the railroad commission of texas. No emergency responders were involved. No injuries and no fatalities.
Detailed record list
Report Received Date
2023-12-22 00:00:00
Iyear
2023
Report Number
20230118
Supplemental Number
39014
Report Type
Supplemental Final
Operator Id
Name
Kinder Morgan Texas Pipeline Co
Operator Street Address
1001 Louisiana St, Ste 1000
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
-102.2543486
Nrc Rpt Num
Additional Nrc Report Numbers
1385205
Commodity Released Type
Natural Gas
Unintentional Release
4018.1
Intentional Release
15571.8
Accompanying Liquid
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Status When Identified
Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind
Yes
Communication State Fed Ind
No
Ignite Ind
No
Upstream Action Taken
Valve Closure
Downstream Action Taken
Valve Closure
Num Pub Evacuated
0
On Off Shore
Onshore
Onshore State Abbreviation
Tx
Onshore Postal Code
79752
Onshore City Name
Mccamey
Onshore County Name
Upton
Designated Location
Not Applicable
Pipe Fac Name
Php Mccamey Compressor Station
Segment Name
Php Mccamey Compressor Station
Federal
No
Location Type
Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Typical Aboveground Facility Piping Or Appurtenance
Crossing
No
Pipe Facility Type
Intrastate
System Part Involved
Onshore Pipeline, Including Valve Sites
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
2
Puddle Weld Ind
No
Pipe Wall Thickness
0.218
Pipe Smys
42000
Pipe Specification
Api 5l
Pipe Seam Type
Seamless
Pipe Manufacturer
Tenaris
Pipe Coating Type
Paint
Coating Applied Ind
Yes
Installation Year
2023
Manufactured Year
2022
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Crack
Class Location Type
Class 1 Location
Could Be Hca
No
Pir Radius
1100
Heat Damage Ind
No
Non Heat Damage Ind
No
Did Occur In Mca Ind
No
Est Cost Oper Paid
0
Est Cost Unintentional Release
10889
Est Cost Intentional Release
42200
Est Cost Prop Damage
30000
Est Cost Emergency
0
Est Cost Other
2500
Est Cost Other Details
Metallurgical Lab Work
Gas Cost In Mcf
2.71
Prpty
85589
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Wildlife Impact Ind
No
Accident Psig
837
Gas Flow In Pipe In Mcf
2569000
Mop Psig
1440
Mop Cfr Section
192.619(A)(2)
Maop Established Date
2023-09-14 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Maop
Pressure Restriction Ind
No
Gas Required Odorized Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Length Segment Isolated
95093
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
Transmission System
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
Yes
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest No Control Room Ind
Yes
Invest No Controller Ind
Yes
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Material Failure Of Pipe Or Weld
Cause Details
Design-, Construction-, Installation-, Or Fabrication-Related
Pwjf Failure Type
Design-, Construction-, Installation-, Or Fabrication-Related
Field Exam Ind
Yes
Metallurgical Ind
Yes
Fatigue Vibr Related
Yes
Failure Subtype
Mechanical Vibration
Post Constr Pressure Test Val
2225
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
R***** B***** I*
Preparer Title
Pipeline Engineer Ii - Codes And Audit Support
Preparer Email
R************@k***********.com
Preparer Telephone
713-420-2324
Authorizer Name
J**** H********
Authorizer Title
Director - Engineering Codes And Standards
Authorizer Telephone
713-369-9443
Authorizer Email
J**************@k***********.com
Narrative
Reportable gas release occurred on november 25, 2023 with a discovery at 17:20. Personnel was onsite prior to the discovery. Php expansion - php mccamey cs upton county texas. Metallurgical and field analysis confirmed release caused by 2 inch pipe breaking completely off the carrier pipe. Natural gas was released into the air - 4018.1 mcf. The area was evacuated and supervision was called. Operations supervision initiated the internal and external notification. The gas did not ignite. The event was reported to the nrc and the railroad commission of texas. No emergency responders were involved. No injuries and no fatalities.
Report Received Date 2023-12-22 00:00:00
Iyear 2023
Report Number 20230118
Supplemental Number 39014
Report Type Supplemental Final
Operator Id 31451 PHMSA Enforcement
Name Kinder Morgan Texas Pipeline Co
Operator Street Address 1001 Louisiana St, Ste 1000
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77002
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 31.15920034 Google Maps OpenStreetMap
Location Longitude -102.2543486 Google Maps OpenStreetMap
Nrc Rpt Num 1385122 NRC Report How to search
Additional Nrc Report Numbers 1385205
Commodity Released Type Natural Gas
Unintentional Release 4018.1
Intentional Release 15571.8
Accompanying Liquid 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Status When Identified Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind Yes
Communication State Fed Ind No
Ignite Ind No
Upstream Action Taken Valve Closure
Downstream Action Taken Valve Closure
Num Pub Evacuated 0
On Off Shore Onshore
Onshore State Abbreviation Tx
Onshore Postal Code 79752
Onshore City Name Mccamey
Onshore County Name Upton
Designated Location Not Applicable
Pipe Fac Name Php Mccamey Compressor Station
Segment Name Php Mccamey Compressor Station
Federal No
Location Type Operator-Controlled Property
Incident Area Type Aboveground
Incident Area Subtype Typical Aboveground Facility Piping Or Appurtenance
Crossing No
Pipe Facility Type Intrastate
System Part Involved Onshore Pipeline, Including Valve Sites
Item Involved Pipe
Pipe Type Pipe Body
Pipe Diameter 2
Puddle Weld Ind No
Pipe Wall Thickness 0.218
Pipe Smys 42000
Pipe Specification Api 5l
Pipe Seam Type Seamless
Pipe Manufacturer Tenaris
Pipe Coating Type Paint
Coating Applied Ind Yes
Installation Year 2023
Manufactured Year 2022
Material Involved Carbon Steel
Release Type Leak
Leak Type Crack
Class Location Type Class 1 Location
Could Be Hca No
Pir Radius 1100
Heat Damage Ind No
Non Heat Damage Ind No
Did Occur In Mca Ind No
Est Cost Oper Paid 0
Est Cost Unintentional Release 10889
Est Cost Intentional Release 42200
Est Cost Prop Damage 30000
Est Cost Emergency 0
Est Cost Other 2500
Est Cost Other Details Metallurgical Lab Work
Gas Cost In Mcf 2.71
Prpty 85589
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Wildlife Impact Ind No
Accident Psig 837
Gas Flow In Pipe In Mcf 2569000
Mop Psig 1440
Mop Cfr Section 192.619(A)(2) View CFR 49 §192
Maop Established Date 2023-09-14 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Maop
Pressure Restriction Ind No
Gas Required Odorized Ind No
Upstream Valve Type Ind Manual
Downstream Valve Type Ind Manual
Length Segment Isolated 95093
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function Transmission System
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind Yes
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Operator Employee
Investigation Status Yes, specify investigation result(s): (select all that apply)
Invest No Control Room Ind Yes
Invest No Controller Ind Yes
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Material Failure Of Pipe Or Weld
Cause Details Design-, Construction-, Installation-, Or Fabrication-Related
Pwjf Failure Type Design-, Construction-, Installation-, Or Fabrication-Related
Field Exam Ind Yes
Metallurgical Ind Yes
Fatigue Vibr Related Yes
Failure Subtype Mechanical Vibration
Post Constr Pressure Test Val 2225
Collected Data Ind No
Has Hydrtst Conduc Before Ind No
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name R***** B***** I*
Preparer Title Pipeline Engineer Ii - Codes And Audit Support
Preparer Email R************@k***********.com
Preparer Telephone 713-420-2324
Authorizer Name J**** H********
Authorizer Title Director - Engineering Codes And Standards
Authorizer Telephone 713-369-9443
Authorizer Email J**************@k***********.com
Narrative Reportable gas release occurred on november 25, 2023 with a discovery at 17:20. Personnel was onsite prior to the discovery. Php expansion - php mccamey cs upton county texas. Metallurgical and field analysis confirmed release caused by 2 inch pipe breaking completely off the carrier pipe. Natural gas was released into the air - 4018.1 mcf. The area was evacuated and supervision was called. Operations supervision initiated the internal and external notification. The gas did not ignite. The event was reported to the nrc and the railroad commission of texas. No emergency responders were involved. No injuries and no fatalities.

All rights reserved. Copyright © by ClearPHMSA