GTG incident on 2023-10-27 — TX

Operator
Dcp Midstream, Lp
Cause
Corrosion Failure
Commodity
Natural Gas
Program
GTG
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$6,000
Incident datetime
2023-10-27 00:00 UTC
Report number
Location
TX
Narrative
On 10/4/2023 at approximately 6:15am cst a response was initiated to the cm-10 cimarron gathering line based on a low-pressure alarm received by centralized booster monitoring group. Response efforts concluded that the cm-10 line had ruptured at approximately 6:11 am. The orion volunteer fire department chose to close a rural road and evacuate 6 local homes. The line was isolated, secured, and an investigation is underway. At 4pm cst local news coverage released incident and evacuation information unknown to operator. A subsequent flow analysis calculated release volume greater than 3mmcf. Supplemental report 12/12/23 : amended part g to include results from metallurgical analyses indicating internal corrosion caused by top of the line corrosion occurring in an environment containing CO2 and water. Received the metallurgical report 11/16/23. Supplemental report 7/11/24. Added cost of the metallurgical analysis report.
Detailed record list
Report Received Date
2023-10-27 00:00:00
Iyear
2023
Report Number
20230098
Supplemental Number
39842
Report Type
Supplemental Final
Operator Id
Name
Dcp Midstream, Lp
Operator Street Address
2331 Citywest Blvd. Hq-08-S812-02
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77042
Time Zone
Central
Daylight Savings Ind
No
Location Latitude
Location Longitude
Nrc Rpt Num
Additional Nrc Report Numbers
1381240
Commodity Released Type
Natural Gas
Unintentional Release
3200
Intentional Release
0
Accompanying Liquid
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Status When Identified
Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind
Yes
Still Shutdown Ind
Yes
Communication State Fed Ind
Yes
Party Initiated Communication
Local/state/federal Emergency Responder
Ignite Ind
No
Upstream Action Taken
Valve Closure
Downstream Action Taken
Valve Closure
Num Pub Evacuated
6
On Off Shore
Onshore
Onshore State Abbreviation
Ok
Onshore Postal Code
73838
Onshore City Name
Not Within A Municipality
Onshore County Name
Major
Designated Location
Not Applicable
Pipe Fac Name
Cm
Segment Name
Cm 10"
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
48
Other Underground Facilities
No
Crossing
No
Pipe Facility Type
Intrastate
System Part Involved
Onshore Pipeline, Including Valve Sites
Item Involved
Pipe
Pipe Type
Pipe Seam
Pipe Diameter
10.75
Pipe Wall Thickness
0.156
Pipe Smys
52000
Pipe Specification
Api 5lx
Pipe Seam Type
Longitudinal Erw - Unknown Frequency
Pipe Manufacturer
Unknown
Pipe Coating Type
Coal Tar
Coating Applied Ind
Unknown
Installation Year
1968
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Rupture
Rupture Orient
Circumferential
Rupture Length
120
Rupture Width
10
Class Location Type
Class 1 Location
Could Be Hca
No
Pir Radius
234
Heat Damage Ind
No
Non Heat Damage Ind
No
Did Occur In Mca Ind
No
Est Cost Oper Paid
0
Est Cost Unintentional Release
10240
Est Cost Intentional Release
0
Est Cost Prop Damage
6000
Est Cost Emergency
1800
Est Cost Other
8200
Est Cost Other Details
Cost Of Metallurgical Analysis.
Gas Cost In Mcf
3.2
Prpty
26240
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
6
Num Business Building Affctd
0
Wildlife Impact Ind
No
Accident Psig
751
Gas Flow In Pipe In Mcf
16959
Mop Psig
1000
Mop Cfr Section
192.619(A)(2)
Maop Established Date
2019-10-10 00:00:00
Maop Reversal Flow Ind
Bi-Directional
Accident Pressure
Pressure Did Not Exceed Maop
Pressure Restriction Ind
No
Gas Required Odorized Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Length Segment Isolated
25823
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
Type C Gathering
Scada In Place Ind
No
Accident Identifier
Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations)
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
Internal Corrosion
Internal External
Internal Corrosion
Int Visual Exam Results
Localized Pitting
Int Water Acid Ind
Yes
Int Metallurgical Basis Ind
Yes
Int Other Loc Ind
Yes
Corrosion Location Details
Top Of The Pipe
Corrosion Inhibitors
Yes
Corrosion Lining
No
Cleaning Dewatering
Yes
Corrosion Coupons
Yes
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
2019
Hydrtst Most Rcnt Pressure
1125
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
L**** M**
Preparer Title
Dot Specialist
Preparer Email
M************@p**.com
Preparer Telephone
405-590-5975
Local Contact Name
L**** M**
Local Contact Email
M************@p**.com
Local Contact Telephone
405-590-5975
Authorizer Name
M*** P*****
Authorizer Title
Supervisor Pipeline Regulatory
Authorizer Telephone
970-397-0732
Authorizer Email
M*************@p**.com
Narrative
On 10/4/2023 at approximately 6:15am cst a response was initiated to the cm-10 cimarron gathering line based on a low-pressure alarm received by centralized booster monitoring group. Response efforts concluded that the cm-10 line had ruptured at approximately 6:11 am. The orion volunteer fire department chose to close a rural road and evacuate 6 local homes. The line was isolated, secured, and an investigation is underway. At 4pm cst local news coverage released incident and evacuation information unknown to operator. A subsequent flow analysis calculated release volume greater than 3mmcf. Supplemental report 12/12/23 : amended part g to include results from metallurgical analyses indicating internal corrosion caused by top of the line corrosion occurring in an environment containing CO2 and water. Received the metallurgical report 11/16/23. Supplemental report 7/11/24. Added cost of the metallurgical analysis report.
Report Received Date 2023-10-27 00:00:00
Iyear 2023
Report Number 20230098
Supplemental Number 39842
Report Type Supplemental Final
Operator Id 31130 PHMSA Enforcement
Name Dcp Midstream, Lp
Operator Street Address 2331 Citywest Blvd. Hq-08-S812-02
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77042
Time Zone Central
Daylight Savings Ind No
Location Latitude 36.2096 Google Maps OpenStreetMap
Location Longitude -98.77207 Google Maps OpenStreetMap
Nrc Rpt Num 1380903 NRC Report How to search
Additional Nrc Report Numbers 1381240
Commodity Released Type Natural Gas
Unintentional Release 3200
Intentional Release 0
Accompanying Liquid 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Status When Identified Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind Yes
Still Shutdown Ind Yes
Communication State Fed Ind Yes
Party Initiated Communication Local/state/federal Emergency Responder
Ignite Ind No
Upstream Action Taken Valve Closure
Downstream Action Taken Valve Closure
Num Pub Evacuated 6
On Off Shore Onshore
Onshore State Abbreviation Ok
Onshore Postal Code 73838
Onshore City Name Not Within A Municipality
Onshore County Name Major
Designated Location Not Applicable
Pipe Fac Name Cm
Segment Name Cm 10"
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 48
Other Underground Facilities No
Crossing No
Pipe Facility Type Intrastate
System Part Involved Onshore Pipeline, Including Valve Sites
Item Involved Pipe
Pipe Type Pipe Seam
Pipe Diameter 10.75
Pipe Wall Thickness 0.156
Pipe Smys 52000
Pipe Specification Api 5lx
Pipe Seam Type Longitudinal Erw - Unknown Frequency
Pipe Manufacturer Unknown
Pipe Coating Type Coal Tar
Coating Applied Ind Unknown
Installation Year 1968
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Rupture
Rupture Orient Circumferential
Rupture Length 120
Rupture Width 10
Class Location Type Class 1 Location
Could Be Hca No
Pir Radius 234
Heat Damage Ind No
Non Heat Damage Ind No
Did Occur In Mca Ind No
Est Cost Oper Paid 0
Est Cost Unintentional Release 10240
Est Cost Intentional Release 0
Est Cost Prop Damage 6000
Est Cost Emergency 1800
Est Cost Other 8200
Est Cost Other Details Cost Of Metallurgical Analysis.
Gas Cost In Mcf 3.2
Prpty 26240
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 6
Num Business Building Affctd 0
Wildlife Impact Ind No
Accident Psig 751
Gas Flow In Pipe In Mcf 16959
Mop Psig 1000
Mop Cfr Section 192.619(A)(2) View CFR 49 §192
Maop Established Date 2019-10-10 00:00:00
Maop Reversal Flow Ind Bi-Directional
Accident Pressure Pressure Did Not Exceed Maop
Pressure Restriction Ind No
Gas Required Odorized Ind No
Upstream Valve Type Ind Manual
Downstream Valve Type Ind Manual
Length Segment Isolated 25823
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function Type C Gathering
Scada In Place Ind No
Accident Identifier Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations)
Investigation Status No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details Internal Corrosion
Internal External Internal Corrosion
Int Visual Exam Results Localized Pitting
Int Water Acid Ind Yes
Int Metallurgical Basis Ind Yes
Int Other Loc Ind Yes
Corrosion Location Details Top Of The Pipe
Corrosion Inhibitors Yes
Corrosion Lining No
Cleaning Dewatering Yes
Corrosion Coupons Yes
Collected Data Ind No
Has Hydrtst Conduc Before Ind Yes
Hydrtst Most Rcnt Year 2019
Hydrtst Most Rcnt Pressure 1125
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name L**** M**
Preparer Title Dot Specialist
Preparer Email M************@p**.com
Preparer Telephone 405-590-5975
Local Contact Name L**** M**
Local Contact Email M************@p**.com
Local Contact Telephone 405-590-5975
Authorizer Name M*** P*****
Authorizer Title Supervisor Pipeline Regulatory
Authorizer Telephone 970-397-0732
Authorizer Email M*************@p**.com
Narrative On 10/4/2023 at approximately 6:15am cst a response was initiated to the cm-10 cimarron gathering line based on a low-pressure alarm received by centralized booster monitoring group. Response efforts concluded that the cm-10 line had ruptured at approximately 6:11 am. The orion volunteer fire department chose to close a rural road and evacuate 6 local homes. The line was isolated, secured, and an investigation is underway. At 4pm cst local news coverage released incident and evacuation information unknown to operator. A subsequent flow analysis calculated release volume greater than 3mmcf. Supplemental report 12/12/23 : amended part g to include results from metallurgical analyses indicating internal corrosion caused by top of the line corrosion occurring in an environment containing CO2 and water. Received the metallurgical report 11/16/23. Supplemental report 7/11/24. Added cost of the metallurgical analysis report.

All rights reserved. Copyright © by ClearPHMSA