Incident details
Operator, cause, commodity and consequences with raw source fields.
GTG incident on 2023-10-16 — TX
Operator
Wtg South Permian Midstream Llc
Cause
Corrosion Failure
Commodity
Natural Gas
Program
GTG
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$150,000
Incident datetime
2023-10-16 00:00 UTC
Report number
Location
TX
Narrative
On 9/17/2023, at about 20:13, occ observed a pressure drop on the sonora 20' pipeline. Occ operator notified field operations of a possible leak. Field operations began to isolate block valve 2 at 21:00 and block valve 3 at 22:00. Location of the event was not found until 01:30 on 9/18/2023. Due to the release of natural gas a safety perimeter was established until 08:00 when the area was deemed safe to enter. At 08:30, it was discovered that event would trigger an nrc reporting for a release of more than 3mmscf. At 09:23, nrc was notified. Pipe debris was collected, preserved and sent to adv integrity in houston for analysis. To prevent further events, multiple ili runs are taking place to identify any other possible issues and repairs will be made as needed.
Detailed record list
Report Received Date
2023-10-16 00:00:00
Iyear
2023
Report Number
20230095
Supplemental Number
39176
Report Type
Supplemental Final
Operator Id
40362
Name
Wtg South Permian Midstream Llc
Operator Street Address
303 Veterans Airpark Lane 5000
Operator City Name
Midland
Operator State Abbreviation
TX
Operator Postal Code
79705
Time Zone
Central
Daylight Savings Ind
No
Location Latitude
31.105645
Location Longitude
-101.291835
Nrc Rpt Num
1379374
Additional Nrc Report Numbers
1379592
Commodity Released Type
Natural Gas
Unintentional Release
25460
Intentional Release
0
Accompanying Liquid
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Status When Identified
Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind
No
Shutdown Explain
Pipeline Was Not Active Due To Maintenance
Communication State Fed Ind
No
Ignite Ind
No
Upstream Action Taken
Valve Closure
Downstream Action Taken
Valve Closure
Num Pub Evacuated
0
On Off Shore
Onshore
Onshore State Abbreviation
Tx
Onshore Postal Code
76932
Onshore City Name
Not Within A Municipality
Onshore County Name
Reagan County
Designated Location
Not Applicable
Pipe Fac Name
Benedum
Segment Name
Sonora 20 Inch
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
48
Other Underground Facilities
No
Crossing
No
Pipe Facility Type
Intrastate
System Part Involved
Onshore Pipeline, Including Valve Sites
Item Involved
Pipe
Pipe Type
Pipe Seam
Pipe Diameter
20
Pipe Wall Thickness
0.25
Pipe Smys
46000
Pipe Specification
X-46
Pipe Seam Type
Longitudinal Erw - Unknown Frequency
Pipe Manufacturer
Unknown
Pipe Coating Type
Coal Tar
Coating Applied Ind
Yes
Installation Year
Unknown
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Rupture
Rupture Orient
Longitudinal
Rupture Length
240
Rupture Width
20
Class Location Type
Class 1 Location
Could Be Hca
No
Pir Radius
422
Heat Damage Ind
No
Non Heat Damage Ind
No
Did Occur In Mca Ind
No
Est Cost Oper Paid
0
Est Cost Unintentional Release
89110
Est Cost Intentional Release
0
Est Cost Prop Damage
150000
Est Cost Emergency
0
Est Cost Other
225000
Est Cost Other Details
Lab Analysis (35k) And New Ili Tool (190k)
Gas Cost In Mcf
3.5
Prpty
464110
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Wildlife Impact Ind
No
Accident Psig
752
Gas Flow In Pipe In Mcf
0
Mop Psig
936
Mop Cfr Section
192.619(A)(1)
Maop Established Date
2015-06-16 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Maop
Pressure Restriction Ind
No
Gas Required Odorized Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Length Segment Isolated
99935
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
Type C Gathering
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
Yes
Accident Identifier
Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations)
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Line was shut-in for service at nearby station. Investigation shows controller could not have caused this event.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Other
Visual Exam Details
None Visible
Other Corrosion Ind
Yes
Corrosion Type Details
High Ph Stress Corrosion Cracking
Metallurgical Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Shielding Evident
Yes
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Cp Annual Survey Year
2022
Prior Damage
No
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Pwf Env Stress Corrosion Ind
Yes
Preparer Name
J**** B******
Preparer Title
Dot Compliance Specialist
Preparer Email
J*******@w***********.com
Preparer Telephone
4329553703
Authorizer Name
J**** B******
Authorizer Title
Dot Compliance Specialist
Authorizer Telephone
4329553703
Authorizer Email
J*******@w***********.com
Narrative
On 9/17/2023, at about 20:13, occ observed a pressure drop on the sonora 20' pipeline. Occ operator notified field operations of a possible leak. Field operations began to isolate block valve 2 at 21:00 and block valve 3 at 22:00. Location of the event was not found until 01:30 on 9/18/2023. Due to the release of natural gas a safety perimeter was established until 08:00 when the area was deemed safe to enter. At 08:30, it was discovered that event would trigger an nrc reporting for a release of more than 3mmscf. At 09:23, nrc was notified. Pipe debris was collected, preserved and sent to adv integrity in houston for analysis. To prevent further events, multiple ili runs are taking place to identify any other possible issues and repairs will be made as needed.
Report Received Date | 2023-10-16 00:00:00 |
---|---|
Iyear | 2023 |
Report Number | 20230095 |
Supplemental Number | 39176 |
Report Type | Supplemental Final |
Operator Id | 40362 PHMSA Enforcement |
Name | Wtg South Permian Midstream Llc |
Operator Street Address | 303 Veterans Airpark Lane 5000 |
Operator City Name | Midland |
Operator State Abbreviation | TX |
Operator Postal Code | 79705 |
Time Zone | Central |
Daylight Savings Ind | No |
Location Latitude | 31.105645 Google Maps OpenStreetMap |
Location Longitude | -101.291835 Google Maps OpenStreetMap |
Nrc Rpt Num | 1379374 NRC Report How to search |
Additional Nrc Report Numbers | 1379592 |
Commodity Released Type | Natural Gas |
Unintentional Release | 25460 |
Intentional Release | 0 |
Accompanying Liquid | 0 |
Fatality Ind | No |
Fatal | 0 |
Injury Ind | No |
Injure | 0 |
Status When Identified | Normal Operation, Includes Pauses During Maintenance |
Shutdown Due Accident Ind | No |
Shutdown Explain | Pipeline Was Not Active Due To Maintenance |
Communication State Fed Ind | No |
Ignite Ind | No |
Upstream Action Taken | Valve Closure |
Downstream Action Taken | Valve Closure |
Num Pub Evacuated | 0 |
On Off Shore | Onshore |
Onshore State Abbreviation | Tx |
Onshore Postal Code | 76932 |
Onshore City Name | Not Within A Municipality |
Onshore County Name | Reagan County |
Designated Location | Not Applicable |
Pipe Fac Name | Benedum |
Segment Name | Sonora 20 Inch |
Federal | No |
Location Type | Pipeline Right-Of-Way |
Incident Area Type | Underground |
Incident Area Subtype | Under Soil |
Depth Of Cover | 48 |
Other Underground Facilities | No |
Crossing | No |
Pipe Facility Type | Intrastate |
System Part Involved | Onshore Pipeline, Including Valve Sites |
Item Involved | Pipe |
Pipe Type | Pipe Seam |
Pipe Diameter | 20 |
Pipe Wall Thickness | 0.25 |
Pipe Smys | 46000 |
Pipe Specification | X-46 |
Pipe Seam Type | Longitudinal Erw - Unknown Frequency |
Pipe Manufacturer | Unknown |
Pipe Coating Type | Coal Tar |
Coating Applied Ind | Yes |
Installation Year | Unknown |
Manufactured Year | Unknown |
Material Involved | Carbon Steel |
Release Type | Rupture |
Rupture Orient | Longitudinal |
Rupture Length | 240 |
Rupture Width | 20 |
Class Location Type | Class 1 Location |
Could Be Hca | No |
Pir Radius | 422 |
Heat Damage Ind | No |
Non Heat Damage Ind | No |
Did Occur In Mca Ind | No |
Est Cost Oper Paid | 0 |
Est Cost Unintentional Release | 89110 |
Est Cost Intentional Release | 0 |
Est Cost Prop Damage | 150000 |
Est Cost Emergency | 0 |
Est Cost Other | 225000 |
Est Cost Other Details | Lab Analysis (35k) And New Ili Tool (190k) |
Gas Cost In Mcf | 3.5 |
Prpty | 464110 |
Num Persons Hosp Not Ovnght | 0 |
Num Injured Treated By Emt | 0 |
Num Resident Building Affctd | 0 |
Num Business Building Affctd | 0 |
Wildlife Impact Ind | No |
Accident Psig | 752 |
Gas Flow In Pipe In Mcf | 0 |
Mop Psig | 936 |
Mop Cfr Section | 192.619(A)(1) View CFR 49 §192 |
Maop Established Date | 2015-06-16 00:00:00 |
Maop Reversal Flow Ind | No |
Accident Pressure | Pressure Did Not Exceed Maop |
Pressure Restriction Ind | No |
Gas Required Odorized Ind | No |
Upstream Valve Type Ind | Manual |
Downstream Valve Type Ind | Manual |
Length Segment Isolated | 99935 |
Internal Inspection Ind | Yes |
Operation Complications Ind | No |
Pipeline Function | Type C Gathering |
Scada In Place Ind | Yes |
Scada Operating Ind | Yes |
Scada Functional Ind | Yes |
Scada Detection Ind | Yes |
Scada Conf Ind | Yes |
Accident Identifier | Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations) |
Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
Investigation Status Details | Line was shut-in for service at nearby station. Investigation shows controller could not have caused this event. |
Employee Drug Test Ind | No |
Contractor Drug Test Ind | No |
Cause | Corrosion Failure |
Cause Details | External Corrosion |
Internal External | External Corrosion |
Visual Exam Results | Other |
Visual Exam Details | None Visible |
Other Corrosion Ind | Yes |
Corrosion Type Details | High Ph Stress Corrosion Cracking |
Metallurgical Basis Ind | Yes |
Underground Location | Yes |
Under Cathodic Protection Ind | Yes |
Shielding Evident | Yes |
Cathodic Survey Type | Yes |
Cp Annual Survey Ind | Yes |
Cp Annual Survey Year | 2022 |
Prior Damage | No |
Collected Data Ind | No |
Has Hydrtst Conduc Before Ind | No |
Direct Asmnt Conducted | No |
Non Destructive Exam Ind | No |
Pwf Env Stress Corrosion Ind | Yes |
Preparer Name | J**** B****** |
Preparer Title | Dot Compliance Specialist |
Preparer Email | J*******@w***********.com |
Preparer Telephone | 4329553703 |
Authorizer Name | J**** B****** |
Authorizer Title | Dot Compliance Specialist |
Authorizer Telephone | 4329553703 |
Authorizer Email | J*******@w***********.com |
Narrative | On 9/17/2023, at about 20:13, occ observed a pressure drop on the sonora 20' pipeline. Occ operator notified field operations of a possible leak. Field operations began to isolate block valve 2 at 21:00 and block valve 3 at 22:00. Location of the event was not found until 01:30 on 9/18/2023. Due to the release of natural gas a safety perimeter was established until 08:00 when the area was deemed safe to enter. At 08:30, it was discovered that event would trigger an nrc reporting for a release of more than 3mmscf. At 09:23, nrc was notified. Pipe debris was collected, preserved and sent to adv integrity in houston for analysis. To prevent further events, multiple ili runs are taking place to identify any other possible issues and repairs will be made as needed. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA