Incident details
Operator, cause, commodity and consequences with raw source fields.
GTG incident on 2023-10-04 — TX
Operator
Enterprise Products Operating Llc
Cause
Corrosion Failure
Commodity
Natural Gas
Program
GTG
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$68,000
Incident datetime
2023-10-04 00:00 UTC
Report number
Location
TX
Narrative
On 9-9-2023 at 13:36 ct, the controller observed a scada pressure drop and at 13:40 pm, enterprise was notified of a potential pipeline release and fire in eddy county, nm. The controller notified operations to investigate. At 14:00 ct, enterprise personnel arrived onsite to confirm the leak location and proceeded to isolate the ruptured segment. Local first responders (eddy county sheriff department, eddy county fire department and carlsbad police department) were also present to assist. At 20:09 ct, all connecting pipelines to line a-18 were isolated. On 9-9-2023, the pipeline fire self-extinguished. On 9-15-2023, line a-18 was repaired and returned into service. The pipe was transported to the laboratory for metallurgical analysis. Laboratory analysis determined that the pipeline rupture occurred at approximately the 7:00 o'clock orientation due to internal corrosion at erw long seam.
Detailed record list
Report Received Date
2023-10-04 00:00:00
Iyear
2023
Report Number
20230093
Supplemental Number
39067
Report Type
Supplemental Final
Operator Id
31618
Name
Enterprise Products Operating Llc
Operator Street Address
1100 Louisiana Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
32.46677
Location Longitude
-104.302272
Nrc Rpt Num
1378634
Additional Nrc Report Numbers
1378716, 1378748
Commodity Released Type
Natural Gas
Unintentional Release
17000
Intentional Release
0
Accompanying Liquid
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Status When Identified
Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind
Yes
Communication State Fed Ind
Yes
Party Initiated Communication
Local/state/federal Emergency Responder
Ignite Ind
Yes
How Extinguished
Allowed To Burn Out
Gas Consumed By Fire In Mcf
17000
Explode Ind
No
Upstream Action Taken
Valve Closure
Downstream Action Taken
Valve Closure
Num Pub Evacuated
0
On Off Shore
Onshore
Onshore State Abbreviation
Nm
Onshore Postal Code
88220
Onshore City Name
Not Within A Municipality
Onshore County Name
Eddy
Designated Location
Not Applicable
Pipe Fac Name
A-18 Lateral
Segment Name
A-18
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
48
Other Underground Facilities
No
Crossing
No
Pipe Facility Type
Intrastate
System Part Involved
Onshore Pipeline, Including Valve Sites
Item Involved
Pipe
Pipe Type
Pipe Seam
Pipe Diameter
12
Pipe Wall Thickness
0.25
Pipe Smys
42000
Pipe Specification
Api 5lx
Pipe Seam Type
Other
Pipe Seam Details
Long Seam Electric Resistance Weld (Erw)
Pipe Manufacturer
Unknown
Pipe Coating Type
Coal Tar
Coating Applied Ind
No
Installation Year
Unknown
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Rupture
Rupture Orient
Longitudinal
Rupture Length
10
Rupture Width
40
Class Location Type
Class 1 Location
Could Be Hca
No
Pir Radius
248
Heat Damage Ind
No
Non Heat Damage Ind
No
Did Occur In Mca Ind
No
Est Cost Oper Paid
0
Est Cost Unintentional Release
61880
Est Cost Intentional Release
0
Est Cost Prop Damage
68000
Est Cost Emergency
5000
Est Cost Other
24000
Est Cost Other Details
Laboratory
Gas Cost In Mcf
3.64
Prpty
158880
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Wildlife Impact Ind
No
Accident Psig
853
Gas Flow In Pipe In Mcf
50
Mop Psig
900
Mop Cfr Section
Other
Mop Cfr Section Details
No Maop Established Due To 12 Inch Diameter, Type C Gathering Pipeline
Maop Established Date
1900-01-01 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Maop
Pressure Restriction Ind
No
Gas Required Odorized Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Length Segment Isolated
81312
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
Type C Gathering
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
Yes
Accident Identifier
Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations)
Investigation Status
Yes, specify investigation result(s): (select all that apply)
Invest No Control Room Ind
Yes
Employee Drug Test Ind
Yes
Contractor Drug Test Ind
No
Num Employees Tested
1
Num Employees Failed
0
Cause
Corrosion Failure
Cause Details
Internal Corrosion
Internal External
Internal Corrosion
Int Visual Exam Results
General Corrosion
Int Water Acid Ind
Yes
Int Metallurgical Basis Ind
Yes
Int Low Point Pipe Loc Ind
Yes
Corrosion Inhibitors
Yes
Corrosion Lining
No
Cleaning Dewatering
No
Corrosion Coupons
No
Collected Data Ind
No
Has Hydrtst Conduc Before Ind
No
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
G***** W*******
Preparer Title
Senior Engineer - Compliance
Preparer Email
G*********@e****.com
Preparer Telephone
832-252-7446
Local Contact Name
G***** W*******
Local Contact Email
G*********@e****.com
Local Contact Telephone
832-252-7446
Authorizer Name
G***** W*******
Authorizer Title
Senior Engineer - Compliance
Authorizer Telephone
832-252-7446
Authorizer Email
G*********@e****.com
Narrative
On 9-9-2023 at 13:36 ct, the controller observed a scada pressure drop and at 13:40 pm, enterprise was notified of a potential pipeline release and fire in eddy county, nm. The controller notified operations to investigate. At 14:00 ct, enterprise personnel arrived onsite to confirm the leak location and proceeded to isolate the ruptured segment. Local first responders (eddy county sheriff department, eddy county fire department and carlsbad police department) were also present to assist. At 20:09 ct, all connecting pipelines to line a-18 were isolated. On 9-9-2023, the pipeline fire self-extinguished. On 9-15-2023, line a-18 was repaired and returned into service. The pipe was transported to the laboratory for metallurgical analysis. Laboratory analysis determined that the pipeline rupture occurred at approximately the 7:00 o'clock orientation due to internal corrosion at erw long seam.
Report Received Date | 2023-10-04 00:00:00 |
---|---|
Iyear | 2023 |
Report Number | 20230093 |
Supplemental Number | 39067 |
Report Type | Supplemental Final |
Operator Id | 31618 PHMSA Enforcement |
Name | Enterprise Products Operating Llc |
Operator Street Address | 1100 Louisiana Street |
Operator City Name | Houston |
Operator State Abbreviation | TX |
Operator Postal Code | 77002 |
Time Zone | Central |
Daylight Savings Ind | Yes |
Location Latitude | 32.46677 Google Maps OpenStreetMap |
Location Longitude | -104.302272 Google Maps OpenStreetMap |
Nrc Rpt Num | 1378634 NRC Report How to search |
Additional Nrc Report Numbers | 1378716, 1378748 |
Commodity Released Type | Natural Gas |
Unintentional Release | 17000 |
Intentional Release | 0 |
Accompanying Liquid | 0 |
Fatality Ind | No |
Fatal | 0 |
Injury Ind | No |
Injure | 0 |
Status When Identified | Normal Operation, Includes Pauses During Maintenance |
Shutdown Due Accident Ind | Yes |
Communication State Fed Ind | Yes |
Party Initiated Communication | Local/state/federal Emergency Responder |
Ignite Ind | Yes |
How Extinguished | Allowed To Burn Out |
Gas Consumed By Fire In Mcf | 17000 |
Explode Ind | No |
Upstream Action Taken | Valve Closure |
Downstream Action Taken | Valve Closure |
Num Pub Evacuated | 0 |
On Off Shore | Onshore |
Onshore State Abbreviation | Nm |
Onshore Postal Code | 88220 |
Onshore City Name | Not Within A Municipality |
Onshore County Name | Eddy |
Designated Location | Not Applicable |
Pipe Fac Name | A-18 Lateral |
Segment Name | A-18 |
Federal | No |
Location Type | Pipeline Right-Of-Way |
Incident Area Type | Underground |
Incident Area Subtype | Under Soil |
Depth Of Cover | 48 |
Other Underground Facilities | No |
Crossing | No |
Pipe Facility Type | Intrastate |
System Part Involved | Onshore Pipeline, Including Valve Sites |
Item Involved | Pipe |
Pipe Type | Pipe Seam |
Pipe Diameter | 12 |
Pipe Wall Thickness | 0.25 |
Pipe Smys | 42000 |
Pipe Specification | Api 5lx |
Pipe Seam Type | Other |
Pipe Seam Details | Long Seam Electric Resistance Weld (Erw) |
Pipe Manufacturer | Unknown |
Pipe Coating Type | Coal Tar |
Coating Applied Ind | No |
Installation Year | Unknown |
Manufactured Year | Unknown |
Material Involved | Carbon Steel |
Release Type | Rupture |
Rupture Orient | Longitudinal |
Rupture Length | 10 |
Rupture Width | 40 |
Class Location Type | Class 1 Location |
Could Be Hca | No |
Pir Radius | 248 |
Heat Damage Ind | No |
Non Heat Damage Ind | No |
Did Occur In Mca Ind | No |
Est Cost Oper Paid | 0 |
Est Cost Unintentional Release | 61880 |
Est Cost Intentional Release | 0 |
Est Cost Prop Damage | 68000 |
Est Cost Emergency | 5000 |
Est Cost Other | 24000 |
Est Cost Other Details | Laboratory |
Gas Cost In Mcf | 3.64 |
Prpty | 158880 |
Num Persons Hosp Not Ovnght | 0 |
Num Injured Treated By Emt | 0 |
Num Resident Building Affctd | 0 |
Num Business Building Affctd | 0 |
Wildlife Impact Ind | No |
Accident Psig | 853 |
Gas Flow In Pipe In Mcf | 50 |
Mop Psig | 900 |
Mop Cfr Section | Other View CFR 49 §192 |
Mop Cfr Section Details | No Maop Established Due To 12 Inch Diameter, Type C Gathering Pipeline |
Maop Established Date | 1900-01-01 00:00:00 |
Maop Reversal Flow Ind | No |
Accident Pressure | Pressure Did Not Exceed Maop |
Pressure Restriction Ind | No |
Gas Required Odorized Ind | No |
Upstream Valve Type Ind | Manual |
Downstream Valve Type Ind | Manual |
Length Segment Isolated | 81312 |
Internal Inspection Ind | Yes |
Operation Complications Ind | No |
Pipeline Function | Type C Gathering |
Scada In Place Ind | Yes |
Scada Operating Ind | Yes |
Scada Functional Ind | Yes |
Scada Detection Ind | Yes |
Scada Conf Ind | Yes |
Accident Identifier | Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations) |
Investigation Status | Yes, specify investigation result(s): (select all that apply) |
Invest No Control Room Ind | Yes |
Employee Drug Test Ind | Yes |
Contractor Drug Test Ind | No |
Num Employees Tested | 1 |
Num Employees Failed | 0 |
Cause | Corrosion Failure |
Cause Details | Internal Corrosion |
Internal External | Internal Corrosion |
Int Visual Exam Results | General Corrosion |
Int Water Acid Ind | Yes |
Int Metallurgical Basis Ind | Yes |
Int Low Point Pipe Loc Ind | Yes |
Corrosion Inhibitors | Yes |
Corrosion Lining | No |
Cleaning Dewatering | No |
Corrosion Coupons | No |
Collected Data Ind | No |
Has Hydrtst Conduc Before Ind | No |
Direct Asmnt Conducted | No |
Non Destructive Exam Ind | No |
Preparer Name | G***** W******* |
Preparer Title | Senior Engineer - Compliance |
Preparer Email | G*********@e****.com |
Preparer Telephone | 832-252-7446 |
Local Contact Name | G***** W******* |
Local Contact Email | G*********@e****.com |
Local Contact Telephone | 832-252-7446 |
Authorizer Name | G***** W******* |
Authorizer Title | Senior Engineer - Compliance |
Authorizer Telephone | 832-252-7446 |
Authorizer Email | G*********@e****.com |
Narrative | On 9-9-2023 at 13:36 ct, the controller observed a scada pressure drop and at 13:40 pm, enterprise was notified of a potential pipeline release and fire in eddy county, nm. The controller notified operations to investigate. At 14:00 ct, enterprise personnel arrived onsite to confirm the leak location and proceeded to isolate the ruptured segment. Local first responders (eddy county sheriff department, eddy county fire department and carlsbad police department) were also present to assist. At 20:09 ct, all connecting pipelines to line a-18 were isolated. On 9-9-2023, the pipeline fire self-extinguished. On 9-15-2023, line a-18 was repaired and returned into service. The pipe was transported to the laboratory for metallurgical analysis. Laboratory analysis determined that the pipeline rupture occurred at approximately the 7:00 o'clock orientation due to internal corrosion at erw long seam. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA