Incident details
Operator, cause, commodity and consequences with raw source fields.
GTG incident on 2023-09-01 — TX
Operator
Cheniere Corpus Christi Pipeline
Cause
Equipment Failure
Commodity
Natural Gas
Program
GTG
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$0
Incident datetime
2023-09-01 00:00 UTC
Report number
Location
TX
Narrative
At 04:14 on 08/19/23 the control center received a critical alarm indicating the station esd was activated. All compressors were shutdown and isolation valves were closed in the station. Upon activation of the esd the compressor station began an entire blowdown of natural gas. The onsite operator went to the compressor building to determine if there was a fire or any gas detected within the building. Once confirmed there was no immediate danger, the operator began closing off the manual block valves to reduce the venting of gas emissions to the atmosphere. Additional operators were called out to assist the onsite operator and arrived at 05:00. The operators reviewed all alarms and found esd 9832u was activated. During the troubleshooting of the esd switch, it was determined the esd rio fuse was blown which caused the esd to activate. The fuse was replaced and all circuits were verified and the esd cleared. At 05:39 the compressor units and station piping were pressured up to normal operating pressure. The first compressor unit was started and put back into service at 07:00 and the second compressor unit was back in service at 07:30. All other compressor units are pressured up and are on standby. All required notifications were submitted and the compressor station was returned to normal operations at 09:45. Final report
Detailed record list
Report Received Date
2023-09-01 00:00:00
Iyear
2023
Report Number
20230082
Supplemental Number
39054
Report Type
Supplemental Final
Operator Id
39429
Name
Cheniere Corpus Christi Pipeline
Operator Street Address
845 Texas St. Suite 1250
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
28.0922
Location Longitude
-93.49317
Nrc Rpt Num
1376645
Commodity Released Type
Natural Gas
Unintentional Release
3984
Intentional Release
0
Accompanying Liquid
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Status When Identified
Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind
Yes
Communication State Fed Ind
No
Ignite Ind
No
Num Pub Evacuated
0
On Off Shore
Onshore
Onshore State Abbreviation
Tx
Onshore Postal Code
78387
Onshore City Name
Not Within A Municipality
Onshore County Name
San Patricio
Designated Location
Survey Station No.
Designated Name
1145+69
Pipe Fac Name
Cheniere Corpus Christi Pipeline
Segment Name
Sinton Compressor Station
Federal
No
Location Type
Operator-Controlled Property
Incident Area Type
Aboveground
Incident Area Subtype
Other
Incident Area Details
Compressor Station Esd Shutdown
Crossing
No
Pipe Facility Type
Interstate
System Part Involved
Onshore Compressor Station Equipment And Piping
Item Involved
Compressor
Installation Year
2017
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Other
Release Type Details
Compressor Station Esd Activation, Blowdown Of Natural Gas From Facility.
Class Location Type
Class 1 Location
Could Be Hca
No
Pir Radius
1330
Heat Damage Ind
No
Non Heat Damage Ind
No
Did Occur In Mca Ind
No
Est Cost Oper Paid
0
Est Cost Unintentional Release
10677
Est Cost Intentional Release
0
Est Cost Prop Damage
0
Est Cost Emergency
0
Est Cost Other
0
Gas Cost In Mcf
2.68
Prpty
10677
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Wildlife Impact Ind
No
Accident Psig
1220
Gas Flow In Pipe In Mcf
2230000
Mop Psig
1440
Mop Cfr Section
192.619(A)(1)
Maop Established Date
2018-03-09 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Maop
Pressure Restriction Ind
No
Gas Required Odorized Ind
No
Pipeline Function
Transmission System
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
Yes
Scada Conf Ind
Yes
Accident Identifier
Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations)
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
No control room or controller action was required.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Malfunction Of Control/relief Equipment
Eq Failure Type
Malfunction Of Control/relief Equipment
Esd System Failure Ind
Yes
Eq Additional Other Ind
Yes
Eq Additional Other Details
Faulty Fuse
Eqf Control Releaf Ind
Yes
Preparer Name
P*** F******
Preparer Title
Manager Pipeline Regulatory Compliance
Preparer Email
P***********@c*******.com
Preparer Telephone
713-375-5855
Preparer Fax
713-375-6000
Local Contact Name
J** C****
Local Contact Email
J********@c*******.com
Local Contact Telephone
361-977-1885
Authorizer Name
C**** W*******
Authorizer Title
Vice President Pipeline Operations
Authorizer Telephone
713-375-5662
Authorizer Email
C*************@c*******.com
Narrative
At 04:14 on 08/19/23 the control center received a critical alarm indicating the station esd was activated. All compressors were shutdown and isolation valves were closed in the station. Upon activation of the esd the compressor station began an entire blowdown of natural gas. The onsite operator went to the compressor building to determine if there was a fire or any gas detected within the building. Once confirmed there was no immediate danger, the operator began closing off the manual block valves to reduce the venting of gas emissions to the atmosphere. Additional operators were called out to assist the onsite operator and arrived at 05:00. The operators reviewed all alarms and found esd 9832u was activated. During the troubleshooting of the esd switch, it was determined the esd rio fuse was blown which caused the esd to activate. The fuse was replaced and all circuits were verified and the esd cleared. At 05:39 the compressor units and station piping were pressured up to normal operating pressure. The first compressor unit was started and put back into service at 07:00 and the second compressor unit was back in service at 07:30. All other compressor units are pressured up and are on standby. All required notifications were submitted and the compressor station was returned to normal operations at 09:45. Final report
Report Received Date | 2023-09-01 00:00:00 |
---|---|
Iyear | 2023 |
Report Number | 20230082 |
Supplemental Number | 39054 |
Report Type | Supplemental Final |
Operator Id | 39429 PHMSA Enforcement |
Name | Cheniere Corpus Christi Pipeline |
Operator Street Address | 845 Texas St. Suite 1250 |
Operator City Name | Houston |
Operator State Abbreviation | TX |
Operator Postal Code | 77002 |
Time Zone | Central |
Daylight Savings Ind | Yes |
Location Latitude | 28.0922 Google Maps OpenStreetMap |
Location Longitude | -93.49317 Google Maps OpenStreetMap |
Nrc Rpt Num | 1376645 NRC Report How to search |
Commodity Released Type | Natural Gas |
Unintentional Release | 3984 |
Intentional Release | 0 |
Accompanying Liquid | 0 |
Fatality Ind | No |
Fatal | 0 |
Injury Ind | No |
Injure | 0 |
Status When Identified | Normal Operation, Includes Pauses During Maintenance |
Shutdown Due Accident Ind | Yes |
Communication State Fed Ind | No |
Ignite Ind | No |
Num Pub Evacuated | 0 |
On Off Shore | Onshore |
Onshore State Abbreviation | Tx |
Onshore Postal Code | 78387 |
Onshore City Name | Not Within A Municipality |
Onshore County Name | San Patricio |
Designated Location | Survey Station No. |
Designated Name | 1145+69 |
Pipe Fac Name | Cheniere Corpus Christi Pipeline |
Segment Name | Sinton Compressor Station |
Federal | No |
Location Type | Operator-Controlled Property |
Incident Area Type | Aboveground |
Incident Area Subtype | Other |
Incident Area Details | Compressor Station Esd Shutdown |
Crossing | No |
Pipe Facility Type | Interstate |
System Part Involved | Onshore Compressor Station Equipment And Piping |
Item Involved | Compressor |
Installation Year | 2017 |
Manufactured Year | Unknown |
Material Involved | Carbon Steel |
Release Type | Other |
Release Type Details | Compressor Station Esd Activation, Blowdown Of Natural Gas From Facility. |
Class Location Type | Class 1 Location |
Could Be Hca | No |
Pir Radius | 1330 |
Heat Damage Ind | No |
Non Heat Damage Ind | No |
Did Occur In Mca Ind | No |
Est Cost Oper Paid | 0 |
Est Cost Unintentional Release | 10677 |
Est Cost Intentional Release | 0 |
Est Cost Prop Damage | 0 |
Est Cost Emergency | 0 |
Est Cost Other | 0 |
Gas Cost In Mcf | 2.68 |
Prpty | 10677 |
Num Persons Hosp Not Ovnght | 0 |
Num Injured Treated By Emt | 0 |
Num Resident Building Affctd | 0 |
Num Business Building Affctd | 0 |
Wildlife Impact Ind | No |
Accident Psig | 1220 |
Gas Flow In Pipe In Mcf | 2230000 |
Mop Psig | 1440 |
Mop Cfr Section | 192.619(A)(1) View CFR 49 §192 |
Maop Established Date | 2018-03-09 00:00:00 |
Maop Reversal Flow Ind | No |
Accident Pressure | Pressure Did Not Exceed Maop |
Pressure Restriction Ind | No |
Gas Required Odorized Ind | No |
Pipeline Function | Transmission System |
Scada In Place Ind | Yes |
Scada Operating Ind | Yes |
Scada Functional Ind | Yes |
Scada Detection Ind | Yes |
Scada Conf Ind | Yes |
Accident Identifier | Scada-Based Information (Such As Alarm(S), Alert(S), Event(S), And/or Volume Or Pack Calculations) |
Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
Investigation Status Details | No control room or controller action was required. |
Employee Drug Test Ind | No |
Contractor Drug Test Ind | No |
Cause | Equipment Failure |
Cause Details | Malfunction Of Control/relief Equipment |
Eq Failure Type | Malfunction Of Control/relief Equipment |
Esd System Failure Ind | Yes |
Eq Additional Other Ind | Yes |
Eq Additional Other Details | Faulty Fuse |
Eqf Control Releaf Ind | Yes |
Preparer Name | P*** F****** |
Preparer Title | Manager Pipeline Regulatory Compliance |
Preparer Email | P***********@c*******.com |
Preparer Telephone | 713-375-5855 |
Preparer Fax | 713-375-6000 |
Local Contact Name | J** C**** |
Local Contact Email | J********@c*******.com |
Local Contact Telephone | 361-977-1885 |
Authorizer Name | C**** W******* |
Authorizer Title | Vice President Pipeline Operations |
Authorizer Telephone | 713-375-5662 |
Authorizer Email | C*************@c*******.com |
Narrative | At 04:14 on 08/19/23 the control center received a critical alarm indicating the station esd was activated. All compressors were shutdown and isolation valves were closed in the station. Upon activation of the esd the compressor station began an entire blowdown of natural gas. The onsite operator went to the compressor building to determine if there was a fire or any gas detected within the building. Once confirmed there was no immediate danger, the operator began closing off the manual block valves to reduce the venting of gas emissions to the atmosphere. Additional operators were called out to assist the onsite operator and arrived at 05:00. The operators reviewed all alarms and found esd 9832u was activated. During the troubleshooting of the esd switch, it was determined the esd rio fuse was blown which caused the esd to activate. The fuse was replaced and all circuits were verified and the esd cleared. At 05:39 the compressor units and station piping were pressured up to normal operating pressure. The first compressor unit was started and put back into service at 07:00 and the second compressor unit was back in service at 07:30. All other compressor units are pressured up and are on standby. All required notifications were submitted and the compressor station was returned to normal operations at 09:45. Final report |