GD incident on 2023-12-04 — MA

Operator
Nstar Gas Company
Cause
Excavation Issue
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$2,771
Incident datetime
2023-12-04 00:00 UTC
Report number
Location
MA, NORFOLK
Narrative
During a planned service line replacement, a second party contractor struck a service line causing an ignition and house fire. The residents were not home at that time. A contractor employee sustained a minor injury. The service line was cut off at the main when the situation was deemed safe. The building was demolished the day of the incident. G3.7: mini excavator was being utilized. G3.12: on november 4, the original marks in the public way showing the service line from the service tee to the property line at the left side of the property were visible and accurate. There were no visible markings or flags on the private property. Private property markings were either not applied or not maintained. G3.14 the crew was mechanically excavating the trench for the new service on the private property when they struck the active 1" steel service.
Detailed record list
Report Received Date
2023-12-04 00:00:00
Iyear
2023.0
Report Number
20230072.0
Supplemental Number
40634.0
Report Type
Supplemental Final
Operator Id
Name
Nstar Gas Company
Operator Street Address
157 Cordaville Road
Operator City Name
Southborough
Operator State Abbreviation
MA
Operator Postal Code
1772.0
Time Zone
Eastern
Daylight Savings Ind
Yes
Location Street Address
126 Prince St
Location City Name
Needham
Location County Name
Norfolk
Location State Abbreviation
MA
Location Postal Code
2492.0
Location Latitude
Location Longitude
Flow Cont Service Valve Ind
Yes
Nrc Rpt Num
Additional Nrc Report Numbers
1383554.0
Commodity Released Type
Natural Gas
Unintentional Release
72.0
Intentional Release
0.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
Yes
How Extinguished
Local/state/federal Emergency Responder
Gas Consumed By Fire In Mcf
72
Explode Ind
Yes
Num Pub Evacuated
0.0
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Federal
No
Location Type
Private Property
Incident Area Type
Underground
Incident Area Subtype
Exposed Due To Excavation
Depth Of Cover
19.0
Other Underground Facilities
No
Crossing
No
Pipe Facility Type
Investor Owned
System Part Involved
Service
Installation Year
1963.0
Customer Type
Single Family Residential
Was Efv Installed Before Ind
No
Curb Valve Inst Before Inc Ind
Yes
Pipe Diameter
1.0
Pipe Specification
Unknown
Pipe Manufacturer
Unknown
Material Involved
Steel
Steel Seam Type
Seamless
Wt Steel
0.133
Release Type
Other
Release Type Details
Excavation Damage From Contact With Small Excavator
Class Location Type
Class 3 Location
Est Cost Oper Paid
350900.0
Est Cost Prop Damage
2771.0
Est Cost Emergency
37907.0
Est Cost Other
0.0
Est Cost Other Details
2a: Based On Assessed Dwelling Value. Responsibility For Reimbursement Tbd.
Gas Cost In Mcf
7.68
Est Cost Unintentional Release
553.0
Est Cost Intentional Release
0.0
Prpty
392131.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
1.0
Num Persons Hosp Not Ovnght
1.0
Num Injured Treated By Emt
0.0
Num Resident Building Affctd
1.0
Num Business Building Affctd
0.0
Accident Psig
55.9
Normal Psig
55.9
Mop Psig
60.0
Mop Cfr Section
192.619(A)(2)
Maop Established Date
1963-06-10 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
Injection Pump
Gas Odorized Lvl Not Msrd Ind
Yes
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Contractor Working For The Operator
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
This was an excavator damage by 2nd party contractor.
Employee Drug Test Ind
No
Contractor Drug Test Ind
Yes
Num Contractors Tested
3
Num Contractors Failed
0
Cause
Excavation Damage
Cause Details
Excavation Damage By Operator's Contractor (Second Party)
Ex Party Type
Excavation Damage By Operator's Contractor (Second Party)
Prior Notification Ind
Yes
One Call System Ind
Yes
Excavator Ind
Yes
Contractor Ind
Yes
State Law Exempt Ind
No
Notify Cga Dirt
No
Private Row Ind
Yes
Private Subtype
Private Landowner
Joint Trench Ind
No
Cross Bore Ind
No
Depth Of Grade
18� � 36�
Excavator Type
Contractor
Excavator Equipment
Unknown/other
Work Performed
Natural Gas
One Call Notified Ind
Yes
One Call Ticket Num
2023431452.0
White Lined Ind
Unknown
Locator Type
Contract Locator
Visible Marks
No
Service Interruption
Unknown/other
Root Cause Category
Excavation Issue
Root Cause Type
Improper Backfilling Practices
Excvtn Dmg Op Contractor Ind
Yes
Preparer Name
K******** S*****
Preparer Title
Manager Compliance
Preparer Email
K***************@e*********.com
Preparer Telephone
5088641836
Local Contact Name
K******** S*****
Local Contact Email
K***************@e*********.com
Local Contact Telephone
5088641836
Authorizer Name
K******** S*****
Authorizer Title
Manager Compliance
Authorizer Telephone
5088641836
Authorizer Email
K***************@e*********.com
Narrative
During a planned service line replacement, a second party contractor struck a service line causing an ignition and house fire. The residents were not home at that time. A contractor employee sustained a minor injury. The service line was cut off at the main when the situation was deemed safe. The building was demolished the day of the incident. G3.7: mini excavator was being utilized. G3.12: on november 4, the original marks in the public way showing the service line from the service tee to the property line at the left side of the property were visible and accurate. There were no visible markings or flags on the private property. Private property markings were either not applied or not maintained. G3.14 the crew was mechanically excavating the trench for the new service on the private property when they struck the active 1" steel service.
Report Received Date 2023-12-04 00:00:00
Iyear 2023.0
Report Number 20230072.0
Supplemental Number 40634.0
Report Type Supplemental Final
Operator Id 2652 PHMSA Enforcement
Name Nstar Gas Company
Operator Street Address 157 Cordaville Road
Operator City Name Southborough
Operator State Abbreviation MA
Operator Postal Code 1772.0
Time Zone Eastern
Daylight Savings Ind Yes
Location Street Address 126 Prince St
Location City Name Needham
Location County Name Norfolk
Location State Abbreviation MA
Location Postal Code 2492.0
Location Latitude 42.27603 Google Maps OpenStreetMap
Location Longitude -71.22185 Google Maps OpenStreetMap
Flow Cont Service Valve Ind Yes
Nrc Rpt Num 1383441.0 NRC Report How to search
Additional Nrc Report Numbers 1383554.0
Commodity Released Type Natural Gas
Unintentional Release 72.0
Intentional Release 0.0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Ignite Ind Yes
How Extinguished Local/state/federal Emergency Responder
Gas Consumed By Fire In Mcf 72
Explode Ind Yes
Num Pub Evacuated 0.0
Communication State Fed Ind Yes
Party Initiated Communication Operator
Federal No
Location Type Private Property
Incident Area Type Underground
Incident Area Subtype Exposed Due To Excavation
Depth Of Cover 19.0
Other Underground Facilities No
Crossing No
Pipe Facility Type Investor Owned
System Part Involved Service
Installation Year 1963.0
Customer Type Single Family Residential
Was Efv Installed Before Ind No
Curb Valve Inst Before Inc Ind Yes
Pipe Diameter 1.0
Pipe Specification Unknown
Pipe Manufacturer Unknown
Material Involved Steel
Steel Seam Type Seamless
Wt Steel 0.133
Release Type Other
Release Type Details Excavation Damage From Contact With Small Excavator
Class Location Type Class 3 Location
Est Cost Oper Paid 350900.0
Est Cost Prop Damage 2771.0
Est Cost Emergency 37907.0
Est Cost Other 0.0
Est Cost Other Details 2a: Based On Assessed Dwelling Value. Responsibility For Reimbursement Tbd.
Gas Cost In Mcf 7.68
Est Cost Unintentional Release 553.0
Est Cost Intentional Release 0.0
Prpty 392131.0
Commercial Affected 0.0
Industrial Affected 0.0
Residences Affected 1.0
Num Persons Hosp Not Ovnght 1.0
Num Injured Treated By Emt 0.0
Num Resident Building Affctd 1.0
Num Business Building Affctd 0.0
Accident Psig 55.9
Normal Psig 55.9
Mop Psig 60.0
Mop Cfr Section 192.619(A)(2) View CFR 49 §192
Maop Established Date 1963-06-10 00:00:00
Accident Pressure Pressure Did Not Exceed Maop
Gas Odorized System Type Injection Pump
Gas Odorized Lvl Not Msrd Ind Yes
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Contractor Working For The Operator
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details This was an excavator damage by 2nd party contractor.
Employee Drug Test Ind No
Contractor Drug Test Ind Yes
Num Contractors Tested 3
Num Contractors Failed 0
Cause Excavation Damage
Cause Details Excavation Damage By Operator's Contractor (Second Party)
Ex Party Type Excavation Damage By Operator's Contractor (Second Party)
Prior Notification Ind Yes
One Call System Ind Yes
Excavator Ind Yes
Contractor Ind Yes
State Law Exempt Ind No
Notify Cga Dirt No
Private Row Ind Yes
Private Subtype Private Landowner
Joint Trench Ind No
Cross Bore Ind No
Depth Of Grade 18� � 36�
Excavator Type Contractor
Excavator Equipment Unknown/other
Work Performed Natural Gas
One Call Notified Ind Yes
One Call Ticket Num 2023431452.0
White Lined Ind Unknown
Locator Type Contract Locator
Visible Marks No
Service Interruption Unknown/other
Root Cause Category Excavation Issue
Root Cause Type Improper Backfilling Practices
Excvtn Dmg Op Contractor Ind Yes
Preparer Name K******** S*****
Preparer Title Manager Compliance
Preparer Email K***************@e*********.com
Preparer Telephone 5088641836
Local Contact Name K******** S*****
Local Contact Email K***************@e*********.com
Local Contact Telephone 5088641836
Authorizer Name K******** S*****
Authorizer Title Manager Compliance
Authorizer Telephone 5088641836
Authorizer Email K***************@e*********.com
Narrative During a planned service line replacement, a second party contractor struck a service line causing an ignition and house fire. The residents were not home at that time. A contractor employee sustained a minor injury. The service line was cut off at the main when the situation was deemed safe. The building was demolished the day of the incident. G3.7: mini excavator was being utilized. G3.12: on november 4, the original marks in the public way showing the service line from the service tee to the property line at the left side of the property were visible and accurate. There were no visible markings or flags on the private property. Private property markings were either not applied or not maintained. G3.14 the crew was mechanically excavating the trench for the new service on the private property when they struck the active 1" steel service.

All rights reserved. Copyright © by ClearPHMSA