Incident details
Operator, cause, commodity and consequences with raw source fields.
GD incident on 2023-12-01 — NY
Operator
Central Hudson Gas & Electric Corp
Cause
Locating Issue
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities
9 injuries
Property damage (nominal)
$53,220
Incident datetime
2023-12-01 00:00 UTC
Report number
Location
NY, DUTCHESS
Narrative
A contractor was performing work for central hudson that included a main and service replacements on brick row in wappingers falls. The scope of work consisted of replacing approximately 200 ft. Of 2-inch steel main and 6 services. The maop of the main is 30 psig. The gas services on the street were either steel or plastic. On thursday, november 2, 2023, at approximately 12:15 pm, central hudson was notified from a central hudson employee at 7 brick row, wappingers falls, of a gas line that was hit where the company contractor was excavating, which resulted in an explosion and structure fire. Multiple reports of a possible gas explosion were received after this call by our dispatch center. The responding fire departments performed evacuations and then a search and rescue effort for the public and workers on site was completed. A total of 15 people were treated for medical evaluation by emergency medical services and transported if necessary. In part a22 of this report, the general public evacuated is estimated at 25 people and cannot be confirmed due to the fire department response and central hudson crews arriving after the residents have been evacuated already. A central hudson gas foreman was on site at the time of damage and during the ignition. The first central hudson responder arrived on site at 12:19 pm and the building was on fire. Additional central hudson personnel including commercial representatives, gas construction crews, and supervisors were contacted and arrived to the site. At 12:30, the gas crew shut gas off to brick row by closing a distribution line valve. At 12:43 pm, the electricity was shut off that services brick row and the adjacent area. The natural gas main and services were retired and abandoned on brick row following this incident. Once the fire was contained, central hudson and contractor crews performed leak surveys of the immediate and surrounding areas to ensure there were no additional risks. Gas odorant readings were taken in the surrounding areas to verify appropriate odorization of gas and was confirmed.
Detailed record list
Report Received Date
2023-12-01 00:00:00
Iyear
2023.0
Report Number
20230071.0
Supplemental Number
40903.0
Report Type
Supplemental Final
Operator Id
2196
Name
Central Hudson Gas & Electric Corp
Operator Street Address
284 South Avenue
Operator City Name
Poughkeepsie
Operator State Abbreviation
NY
Operator Postal Code
12601.0
Time Zone
Eastern
Daylight Savings Ind
No
Location Street Address
7 Brick Row
Location City Name
Wappingers Falls
Location County Name
Dutchess
Location State Abbreviation
NY
Location Postal Code
12590.0
Location Latitude
41.60136
Location Longitude
-73.918048
Flow Cont Main Valve Ind
Yes
Nrc Rpt Num
1383286.0
Commodity Released Type
Natural Gas
Unintentional Release
13.1
Intentional Release
0.0
Fatality Ind
No
Fatal
0
Injury Ind
Yes
Num Emp Injuries
0
Num Contr Injuries
5
Num Er Injuries
0
Num Worker Injuries
0
Num Gp Injuries
4
Injure
9
Ignite Ind
Yes
How Extinguished
Local/state/federal Emergency Responder
Gas Consumed By Fire In Mcf
13.1
Explode Ind
Yes
Num Pub Evacuated
25.0
Communication State Fed Ind
Yes
Party Initiated Communication
Local/state/federal Emergency Responder
Federal
No
Location Type
Private Property
Incident Area Type
Underground
Incident Area Subtype
Exposed Due To Excavation
Depth Of Cover
24.0
Other Underground Facilities
No
Crossing
No
Pipe Facility Type
Investor Owned
System Part Involved
Service
Installation Year
1952.0
Customer Type
Multi-Family Residential
Was Efv Installed Before Ind
No
Curb Valve Inst Before Inc Ind
Yes
Pipe Diameter
0.75
Pipe Specification
Unknown
Pipe Manufacturer
Unknown
Material Involved
Steel
Steel Seam Type
Other
Steel Seam Type Details
Unknown
Release Type
Mechanical Puncture
Puncture Axial
2.0
Puncture Circum
1.0
Class Location Type
Class 3 Location
Est Cost Oper Paid
1899000.0
Est Cost Prop Damage
53220.0
Est Cost Emergency
25867.0
Est Cost Other
2250.0
Est Cost Other Details
Contractor Charges For Leak Survey.
Gas Cost In Mcf
3.7871
Est Cost Unintentional Release
50.0
Est Cost Intentional Release
0.0
Prpty
1980387.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
6.0
Num Persons Hosp Not Ovnght
1.0
Num Injured Treated By Emt
5.0
Num Resident Building Affctd
9.0
Num Business Building Affctd
0.0
Accident Psig
24.0
Normal Psig
24.0
Mop Psig
30.0
Mop Cfr Section
192.619(C)
Maop Established Date
1952-05-28 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
Injection Pump
Gas Odorized Level
2.5
Scada In Place Ind
No
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
Yes
Num Employees Tested
1
Num Employees Failed
0
Contractor Drug Test Ind
Yes
Num Contractors Tested
3
Num Contractors Failed
0
Cause
Excavation Damage
Cause Details
Excavation Damage By Operator's Contractor (Second Party)
Ex Party Type
Excavation Damage By Operator's Contractor (Second Party)
Prior Notification Ind
Yes
One Call System Ind
Yes
State Law Exempt Ind
No
Notify Cga Dirt
No
Private Row Ind
Yes
Private Subtype
Private Landowner
Joint Trench Ind
No
Cross Bore Ind
No
Depth Of Grade
18� � 36�
Excavator Type
Contractor
Excavator Equipment
Backhoe/trackhoe
Work Performed
Natural Gas
One Call Notified Ind
Yes
One Call Ticket Num
918300000000.0
One Call Center Name
Udig Ny
White Lined Ind
Unknown
Locator Type
Contract Locator
Visible Marks
Yes
Service Interruption
Yes
Service Interruption Hours
9.0
Root Cause Category
Locating Issue
Root Cause Type
Facility Not Marked Due To Incomplete Marks At Damage Location
Preparer Name
J**** A****
Preparer Title
Manager Of Gas Compliance
Preparer Email
J*****@c*****.com
Preparer Telephone
845-416-3887
Local Contact Name
J**** A****
Local Contact Email
J*****@c*****.com
Local Contact Telephone
845-416-3887
Authorizer Name
E*** K*******
Authorizer Title
Vice President Of Operations And Safety
Authorizer Telephone
845-486-5472
Authorizer Email
E********@c*****.com
Narrative
A contractor was performing work for central hudson that included a main and service replacements on brick row in wappingers falls. The scope of work consisted of replacing approximately 200 ft. Of 2-inch steel main and 6 services. The maop of the main is 30 psig. The gas services on the street were either steel or plastic. On thursday, november 2, 2023, at approximately 12:15 pm, central hudson was notified from a central hudson employee at 7 brick row, wappingers falls, of a gas line that was hit where the company contractor was excavating, which resulted in an explosion and structure fire. Multiple reports of a possible gas explosion were received after this call by our dispatch center. The responding fire departments performed evacuations and then a search and rescue effort for the public and workers on site was completed. A total of 15 people were treated for medical evaluation by emergency medical services and transported if necessary. In part a22 of this report, the general public evacuated is estimated at 25 people and cannot be confirmed due to the fire department response and central hudson crews arriving after the residents have been evacuated already. A central hudson gas foreman was on site at the time of damage and during the ignition. The first central hudson responder arrived on site at 12:19 pm and the building was on fire. Additional central hudson personnel including commercial representatives, gas construction crews, and supervisors were contacted and arrived to the site. At 12:30, the gas crew shut gas off to brick row by closing a distribution line valve. At 12:43 pm, the electricity was shut off that services brick row and the adjacent area. The natural gas main and services were retired and abandoned on brick row following this incident. Once the fire was contained, central hudson and contractor crews performed leak surveys of the immediate and surrounding areas to ensure there were no additional risks. Gas odorant readings were taken in the surrounding areas to verify appropriate odorization of gas and was confirmed.
Report Received Date | 2023-12-01 00:00:00 |
---|---|
Iyear | 2023.0 |
Report Number | 20230071.0 |
Supplemental Number | 40903.0 |
Report Type | Supplemental Final |
Operator Id | 2196 PHMSA Enforcement |
Name | Central Hudson Gas & Electric Corp |
Operator Street Address | 284 South Avenue |
Operator City Name | Poughkeepsie |
Operator State Abbreviation | NY |
Operator Postal Code | 12601.0 |
Time Zone | Eastern |
Daylight Savings Ind | No |
Location Street Address | 7 Brick Row |
Location City Name | Wappingers Falls |
Location County Name | Dutchess |
Location State Abbreviation | NY |
Location Postal Code | 12590.0 |
Location Latitude | 41.60136 Google Maps OpenStreetMap |
Location Longitude | -73.918048 Google Maps OpenStreetMap |
Flow Cont Main Valve Ind | Yes |
Nrc Rpt Num | 1383286.0 NRC Report How to search |
Commodity Released Type | Natural Gas |
Unintentional Release | 13.1 |
Intentional Release | 0.0 |
Fatality Ind | No |
Fatal | 0 |
Injury Ind | Yes |
Num Emp Injuries | 0 |
Num Contr Injuries | 5 |
Num Er Injuries | 0 |
Num Worker Injuries | 0 |
Num Gp Injuries | 4 |
Injure | 9 |
Ignite Ind | Yes |
How Extinguished | Local/state/federal Emergency Responder |
Gas Consumed By Fire In Mcf | 13.1 |
Explode Ind | Yes |
Num Pub Evacuated | 25.0 |
Communication State Fed Ind | Yes |
Party Initiated Communication | Local/state/federal Emergency Responder |
Federal | No |
Location Type | Private Property |
Incident Area Type | Underground |
Incident Area Subtype | Exposed Due To Excavation |
Depth Of Cover | 24.0 |
Other Underground Facilities | No |
Crossing | No |
Pipe Facility Type | Investor Owned |
System Part Involved | Service |
Installation Year | 1952.0 |
Customer Type | Multi-Family Residential |
Was Efv Installed Before Ind | No |
Curb Valve Inst Before Inc Ind | Yes |
Pipe Diameter | 0.75 |
Pipe Specification | Unknown |
Pipe Manufacturer | Unknown |
Material Involved | Steel |
Steel Seam Type | Other |
Steel Seam Type Details | Unknown |
Release Type | Mechanical Puncture |
Puncture Axial | 2.0 |
Puncture Circum | 1.0 |
Class Location Type | Class 3 Location |
Est Cost Oper Paid | 1899000.0 |
Est Cost Prop Damage | 53220.0 |
Est Cost Emergency | 25867.0 |
Est Cost Other | 2250.0 |
Est Cost Other Details | Contractor Charges For Leak Survey. |
Gas Cost In Mcf | 3.7871 |
Est Cost Unintentional Release | 50.0 |
Est Cost Intentional Release | 0.0 |
Prpty | 1980387.0 |
Commercial Affected | 0.0 |
Industrial Affected | 0.0 |
Residences Affected | 6.0 |
Num Persons Hosp Not Ovnght | 1.0 |
Num Injured Treated By Emt | 5.0 |
Num Resident Building Affctd | 9.0 |
Num Business Building Affctd | 0.0 |
Accident Psig | 24.0 |
Normal Psig | 24.0 |
Mop Psig | 30.0 |
Mop Cfr Section | 192.619(C) View CFR 49 §192 |
Maop Established Date | 1952-05-28 00:00:00 |
Accident Pressure | Pressure Did Not Exceed Maop |
Gas Odorized System Type | Injection Pump |
Gas Odorized Level | 2.5 |
Scada In Place Ind | No |
Accident Identifier | Local Operating Personnel, Including Contractors |
Operator Type | Operator Employee |
Investigation Status | No, the facility was not monitored by a controller(s) at the time of the incident |
Employee Drug Test Ind | Yes |
Num Employees Tested | 1 |
Num Employees Failed | 0 |
Contractor Drug Test Ind | Yes |
Num Contractors Tested | 3 |
Num Contractors Failed | 0 |
Cause | Excavation Damage |
Cause Details | Excavation Damage By Operator's Contractor (Second Party) |
Ex Party Type | Excavation Damage By Operator's Contractor (Second Party) |
Prior Notification Ind | Yes |
One Call System Ind | Yes |
State Law Exempt Ind | No |
Notify Cga Dirt | No |
Private Row Ind | Yes |
Private Subtype | Private Landowner |
Joint Trench Ind | No |
Cross Bore Ind | No |
Depth Of Grade | 18� � 36� |
Excavator Type | Contractor |
Excavator Equipment | Backhoe/trackhoe |
Work Performed | Natural Gas |
One Call Notified Ind | Yes |
One Call Ticket Num | 918300000000.0 |
One Call Center Name | Udig Ny |
White Lined Ind | Unknown |
Locator Type | Contract Locator |
Visible Marks | Yes |
Service Interruption | Yes |
Service Interruption Hours | 9.0 |
Root Cause Category | Locating Issue |
Root Cause Type | Facility Not Marked Due To Incomplete Marks At Damage Location |
Preparer Name | J**** A**** |
Preparer Title | Manager Of Gas Compliance |
Preparer Email | J*****@c*****.com |
Preparer Telephone | 845-416-3887 |
Local Contact Name | J**** A**** |
Local Contact Email | J*****@c*****.com |
Local Contact Telephone | 845-416-3887 |
Authorizer Name | E*** K******* |
Authorizer Title | Vice President Of Operations And Safety |
Authorizer Telephone | 845-486-5472 |
Authorizer Email | E********@c*****.com |
Narrative | A contractor was performing work for central hudson that included a main and service replacements on brick row in wappingers falls. The scope of work consisted of replacing approximately 200 ft. Of 2-inch steel main and 6 services. The maop of the main is 30 psig. The gas services on the street were either steel or plastic. On thursday, november 2, 2023, at approximately 12:15 pm, central hudson was notified from a central hudson employee at 7 brick row, wappingers falls, of a gas line that was hit where the company contractor was excavating, which resulted in an explosion and structure fire. Multiple reports of a possible gas explosion were received after this call by our dispatch center. The responding fire departments performed evacuations and then a search and rescue effort for the public and workers on site was completed. A total of 15 people were treated for medical evaluation by emergency medical services and transported if necessary. In part a22 of this report, the general public evacuated is estimated at 25 people and cannot be confirmed due to the fire department response and central hudson crews arriving after the residents have been evacuated already. A central hudson gas foreman was on site at the time of damage and during the ignition. The first central hudson responder arrived on site at 12:19 pm and the building was on fire. Additional central hudson personnel including commercial representatives, gas construction crews, and supervisors were contacted and arrived to the site. At 12:30, the gas crew shut gas off to brick row by closing a distribution line valve. At 12:43 pm, the electricity was shut off that services brick row and the adjacent area. The natural gas main and services were retired and abandoned on brick row following this incident. Once the fire was contained, central hudson and contractor crews performed leak surveys of the immediate and surrounding areas to ensure there were no additional risks. Gas odorant readings were taken in the surrounding areas to verify appropriate odorization of gas and was confirmed. |