Incident details
Operator, cause, commodity and consequences with raw source fields.
GD incident on 2023-10-20 — FL
Operator
Central Florida Gas Corp
Cause
Locating Issue
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$160,000
Incident datetime
2023-10-20 00:00 UTC
Report number
Location
FL, HILLSBOROUGH
Narrative
A sub-contractor for a site contractor was driving steel sheet shoring in the ground on turkey creek rd. The sheet shoring stopped about 8' deep and would not drive any further. The site contractor used a track hoe to dig down to see what the obstruction was and struck a 6" steel gas main and poked a small hole in the pipe. Florida public utilities (central florida gas) technicians were dispatched and closed a key valve and a system valve on either side of the damage, stopping the escaping natural gas. Due to the depth of the pipe and extensive ground water, a new section of steel pipe will need to be installed by directional bore. The sub-contractor did not have a valid locate ticket, the site contractor who hit and punctured the line did have multiple valid locate tickets. A contract locator for fpu had previously marked multiple tickets but did not mark the last update ticket and put in the notes that it was an ongoing project. A contractor for central florida gas began replacing the damaged pipe by directional bore on 9/26/23. The new 6" main was installed, pigged, tested, tied in, purged and put back in service on 10/17/23. 12/29/2023 - final report. No significant changes to previously submitted information. 1/4/2024 - new supplemental and final to make changes to a (4) and c (3a) suggested by PHMSA senior investigator, accident investigation division.
Detailed record list
Report Received Date
2023-10-20 00:00:00
Iyear
2023.0
Report Number
20230060.0
Supplemental Number
39040.0
Report Type
Supplemental Final
Operator Id
2188
Name
Central Florida Gas Corp
Operator Street Address
208 Wildlight Ave
Operator City Name
Yulee
Operator State Abbreviation
FL
Operator Postal Code
32097.0
Time Zone
Eastern
Daylight Savings Ind
Yes
Location Street Address
Turkey Creek Rd.
Location City Name
Plant City
Location County Name
Hillsborough
Location State Abbreviation
FL
Location Postal Code
33566.0
Location Latitude
27.98884
Location Longitude
-82.17046
Flow Cont Key Crit Ind
Yes
Flow Cont Main Valve Ind
Yes
Nrc Rpt Num
1379739.0
Additional Nrc Report Numbers
1379888.0
Commodity Released Type
Natural Gas
Unintentional Release
98.0
Intentional Release
0.0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
No
Num Pub Evacuated
0.0
Communication State Fed Ind
Yes
Party Initiated Communication
Local/state/federal Emergency Responder
Federal
No
Location Type
Utility Right-Of-Way / Easement
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
96.0
Other Underground Facilities
No
Crossing
No
Pipe Facility Type
Investor Owned
System Part Involved
Main
Installation Year
2010.0
Manufactured Year
2010.0
Pipe Diameter
6.0
Pipe Specification
Api 5l
Pipe Manufacturer
Unknown
Material Involved
Steel
Steel Seam Type
Longitudinal Erw - High Frequency
Wt Steel
0.188
Release Type
Mechanical Puncture
Puncture Axial
0.5
Puncture Circum
0.5
Class Location Type
Class 2 Location
Est Cost Oper Paid
0.0
Est Cost Prop Damage
160000.0
Est Cost Emergency
1000.0
Est Cost Other
0.0
Gas Cost In Mcf
3.8
Est Cost Unintentional Release
372.0
Est Cost Intentional Release
0.0
Prpty
161372.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
0.0
Num Persons Hosp Not Ovnght
0.0
Num Injured Treated By Emt
0.0
Num Resident Building Affctd
0.0
Num Business Building Affctd
0.0
Accident Psig
160.0
Normal Psig
165.0
Mop Psig
175.0
Mop Cfr Section
192.619(A)(2)
Maop Established Date
2010-05-06 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
Injection Pump
Gas Odorized Lvl Not Msrd Ind
Yes
Scada In Place Ind
No
Accident Identifier
Notification From Third Party That Caused The Incident
Investigation Status
No, the facility was not monitored by a controller(s) at the time of the incident
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Excavation Damage
Cause Details
Excavation Damage By Third Party
Ex Party Type
Excavation Damage By Third Party
Prior Notification Ind
Yes
One Call System Ind
Yes
State Law Exempt Ind
No
Notify Cga Dirt
Yes
Public Row Ind
Yes
Public Subtype
City Street
Joint Trench Ind
No
Cross Bore Ind
No
Depth Of Grade
> 36�
Excavator Type
Contractor
Excavator Equipment
Backhoe/trackhoe
Work Performed
Drainage
One Call Notified Ind
Yes
One Call Ticket Num
251301840.0
White Lined Ind
No
Locator Type
Contract Locator
Visible Marks
No
Service Interruption
No
Root Cause Category
Locating Issue
Root Cause Type
Facility Not Marked Due To Incomplete Marks At Damage Location
Io Follow Procedure Ind
Yes
Preparer Name
M****** M******
Preparer Email
M*******@f***.com
Preparer Telephone
863 224 0417
Local Contact Name
M****** M******
Local Contact Email
M*******@f***.com
Local Contact Telephone
863 224-0417
Authorizer Name
M****** M******
Authorizer Telephone
863 224-0417
Authorizer Email
M*******@f***.com
Narrative
A sub-contractor for a site contractor was driving steel sheet shoring in the ground on turkey creek rd. The sheet shoring stopped about 8' deep and would not drive any further. The site contractor used a track hoe to dig down to see what the obstruction was and struck a 6" steel gas main and poked a small hole in the pipe. Florida public utilities (central florida gas) technicians were dispatched and closed a key valve and a system valve on either side of the damage, stopping the escaping natural gas. Due to the depth of the pipe and extensive ground water, a new section of steel pipe will need to be installed by directional bore. The sub-contractor did not have a valid locate ticket, the site contractor who hit and punctured the line did have multiple valid locate tickets. A contract locator for fpu had previously marked multiple tickets but did not mark the last update ticket and put in the notes that it was an ongoing project. A contractor for central florida gas began replacing the damaged pipe by directional bore on 9/26/23. The new 6" main was installed, pigged, tested, tied in, purged and put back in service on 10/17/23. 12/29/2023 - final report. No significant changes to previously submitted information. 1/4/2024 - new supplemental and final to make changes to a (4) and c (3a) suggested by PHMSA senior investigator, accident investigation division.
Report Received Date | 2023-10-20 00:00:00 |
---|---|
Iyear | 2023.0 |
Report Number | 20230060.0 |
Supplemental Number | 39040.0 |
Report Type | Supplemental Final |
Operator Id | 2188 PHMSA Enforcement |
Name | Central Florida Gas Corp |
Operator Street Address | 208 Wildlight Ave |
Operator City Name | Yulee |
Operator State Abbreviation | FL |
Operator Postal Code | 32097.0 |
Time Zone | Eastern |
Daylight Savings Ind | Yes |
Location Street Address | Turkey Creek Rd. |
Location City Name | Plant City |
Location County Name | Hillsborough |
Location State Abbreviation | FL |
Location Postal Code | 33566.0 |
Location Latitude | 27.98884 Google Maps OpenStreetMap |
Location Longitude | -82.17046 Google Maps OpenStreetMap |
Flow Cont Key Crit Ind | Yes |
Flow Cont Main Valve Ind | Yes |
Nrc Rpt Num | 1379739.0 NRC Report How to search |
Additional Nrc Report Numbers | 1379888.0 |
Commodity Released Type | Natural Gas |
Unintentional Release | 98.0 |
Intentional Release | 0.0 |
Fatality Ind | No |
Fatal | 0 |
Injury Ind | No |
Injure | 0 |
Ignite Ind | No |
Num Pub Evacuated | 0.0 |
Communication State Fed Ind | Yes |
Party Initiated Communication | Local/state/federal Emergency Responder |
Federal | No |
Location Type | Utility Right-Of-Way / Easement |
Incident Area Type | Underground |
Incident Area Subtype | Under Soil |
Depth Of Cover | 96.0 |
Other Underground Facilities | No |
Crossing | No |
Pipe Facility Type | Investor Owned |
System Part Involved | Main |
Installation Year | 2010.0 |
Manufactured Year | 2010.0 |
Pipe Diameter | 6.0 |
Pipe Specification | Api 5l |
Pipe Manufacturer | Unknown |
Material Involved | Steel |
Steel Seam Type | Longitudinal Erw - High Frequency |
Wt Steel | 0.188 |
Release Type | Mechanical Puncture |
Puncture Axial | 0.5 |
Puncture Circum | 0.5 |
Class Location Type | Class 2 Location |
Est Cost Oper Paid | 0.0 |
Est Cost Prop Damage | 160000.0 |
Est Cost Emergency | 1000.0 |
Est Cost Other | 0.0 |
Gas Cost In Mcf | 3.8 |
Est Cost Unintentional Release | 372.0 |
Est Cost Intentional Release | 0.0 |
Prpty | 161372.0 |
Commercial Affected | 0.0 |
Industrial Affected | 0.0 |
Residences Affected | 0.0 |
Num Persons Hosp Not Ovnght | 0.0 |
Num Injured Treated By Emt | 0.0 |
Num Resident Building Affctd | 0.0 |
Num Business Building Affctd | 0.0 |
Accident Psig | 160.0 |
Normal Psig | 165.0 |
Mop Psig | 175.0 |
Mop Cfr Section | 192.619(A)(2) View CFR 49 §192 |
Maop Established Date | 2010-05-06 00:00:00 |
Accident Pressure | Pressure Did Not Exceed Maop |
Gas Odorized System Type | Injection Pump |
Gas Odorized Lvl Not Msrd Ind | Yes |
Scada In Place Ind | No |
Accident Identifier | Notification From Third Party That Caused The Incident |
Investigation Status | No, the facility was not monitored by a controller(s) at the time of the incident |
Employee Drug Test Ind | No |
Contractor Drug Test Ind | No |
Cause | Excavation Damage |
Cause Details | Excavation Damage By Third Party |
Ex Party Type | Excavation Damage By Third Party |
Prior Notification Ind | Yes |
One Call System Ind | Yes |
State Law Exempt Ind | No |
Notify Cga Dirt | Yes |
Public Row Ind | Yes |
Public Subtype | City Street |
Joint Trench Ind | No |
Cross Bore Ind | No |
Depth Of Grade | > 36� |
Excavator Type | Contractor |
Excavator Equipment | Backhoe/trackhoe |
Work Performed | Drainage |
One Call Notified Ind | Yes |
One Call Ticket Num | 251301840.0 |
White Lined Ind | No |
Locator Type | Contract Locator |
Visible Marks | No |
Service Interruption | No |
Root Cause Category | Locating Issue |
Root Cause Type | Facility Not Marked Due To Incomplete Marks At Damage Location |
Io Follow Procedure Ind | Yes |
Preparer Name | M****** M****** |
Preparer Email | M*******@f***.com |
Preparer Telephone | 863 224 0417 |
Local Contact Name | M****** M****** |
Local Contact Email | M*******@f***.com |
Local Contact Telephone | 863 224-0417 |
Authorizer Name | M****** M****** |
Authorizer Telephone | 863 224-0417 |
Authorizer Email | M*******@f***.com |
Narrative | A sub-contractor for a site contractor was driving steel sheet shoring in the ground on turkey creek rd. The sheet shoring stopped about 8' deep and would not drive any further. The site contractor used a track hoe to dig down to see what the obstruction was and struck a 6" steel gas main and poked a small hole in the pipe. Florida public utilities (central florida gas) technicians were dispatched and closed a key valve and a system valve on either side of the damage, stopping the escaping natural gas. Due to the depth of the pipe and extensive ground water, a new section of steel pipe will need to be installed by directional bore. The sub-contractor did not have a valid locate ticket, the site contractor who hit and punctured the line did have multiple valid locate tickets. A contract locator for fpu had previously marked multiple tickets but did not mark the last update ticket and put in the notes that it was an ongoing project. A contractor for central florida gas began replacing the damaged pipe by directional bore on 9/26/23. The new 6" main was installed, pigged, tested, tied in, purged and put back in service on 10/17/23. 12/29/2023 - final report. No significant changes to previously submitted information. 1/4/2024 - new supplemental and final to make changes to a (4) and c (3a) suggested by PHMSA senior investigator, accident investigation division. |