GD incident on 2023-10-06 — NM

Operator
New Mexico Gas Company
Cause
Pipe, Weld, Or Joint Failure
Commodity
Natural Gas
Program
GD
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$0
Incident datetime
2023-10-06 00:00 UTC
Report number
Location
NM, BERNALILLO
Narrative
On september 7, 2023, an explosion occurred at 14:18 at 4100 ridgeley ave ne in albuquerque, nm 87108. At 14:37, nmgc was notified by albuquerque fire and rescue of a house explosion. Nmgc arrived at the property at 14:52. Gas was escaping from the riser when the nmgc technician arrived. Gas was under control at 15:33 at the riser. Nmgc began probing for gas at 15:33. The nmgc responding crew discovered gas concentration readings of 100% gas in the street directly in front of 4100 ridgeley ave ne. Nmgc exposed the 2-inch pe pipe, where the section of main was offset with a dogleg that was installed in 2017. A 2x3-inch leak clamp was installed as a temporary repair. The section of main was squeezed off at 21:30 and capped as a permanent repair. There were two residents of 4100 ridgeley avenue who were treated for non-life threatening injuries and released. At 17:15, gas odorant testing with a heath odorometer was conducted revealing sufficient odorant at 0.50% gas-in-air (12.5% lel). Additional gas odorant testing with a heath odorometer was performed showing appropriate odorant levels. Laboratory tests were conducted on october 25, 2023 which revealed a lack of complete fusion on butt weld. Regarding questions part a #7 and part a #21c, the form does not allow an entry of "unknown" because a calculation cannot be performed due to limited or unknown information needed to perform the calculation.
Detailed record list
Report Received Date
2023-10-06 00:00:00
Iyear
2023.0
Report Number
20230057.0
Supplemental Number
39364.0
Report Type
Supplemental Final
Operator Id
Name
New Mexico Gas Company
Operator Street Address
7120 Wyoming Blvd N.e. Suite 20
Operator City Name
Albuquerque
Operator State Abbreviation
NM
Operator Postal Code
87109.0
Time Zone
Mountain
Daylight Savings Ind
Yes
Location Street Address
4100 Ridgeley Dr Ne
Location City Name
Albuquerque
Location County Name
Bernalillo
Location State Abbreviation
NM
Location Postal Code
87108.0
Location Latitude
Location Longitude
Flow Cont Squeeze Off Ind
Yes
Flow Cont Other Ind
Yes
Flow Cont Other Detail
2x3 Leak Clamp On Main And Plugged Off Riser
Nrc Rpt Num
Additional Nrc Report Numbers
1378626.0
Commodity Released Type
Natural Gas
Unintentional Release
1.0
Intentional Release
0.083
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Ignite Ind
Yes
How Extinguished
Other
How Extinguished Other Detail
No Residual Fire After Initial Ignition Event.
Gas Consumed By Fire In Mcf
1
Explode Ind
Yes
Num Pub Evacuated
19.0
Federal
No
Location Type
Public Property
Incident Area Type
Underground
Incident Area Subtype
Under Pavement
Depth Of Cover
45.0
Other Underground Facilities
Yes
Crossing
No
Pipe Facility Type
Investor Owned
System Part Involved
Main
Installation Year
2017.0
Manufactured Year
2017.0
Pipe Diameter
2.0
Pipe Specification
Astm D2513
Pipe Manufacturer
Performance Pipe
Material Involved
Plastic
Plastic Type
Polyethylene (Pe)
Plastic Sdr
11
Material Pe Pipe Code
4710
Release Type
Leak
Leak Type
Other
Leak Type Other
Lack Of Complete Fusion
Class Location Type
Class 3 Location
Est Cost Oper Paid
500000.0
Est Cost Prop Damage
0.0
Est Cost Emergency
11250.0
Est Cost Other
0.0
Gas Cost In Mcf
4.99
Est Cost Unintentional Release
5.0
Est Cost Intentional Release
0.0
Prpty
511255.0
Commercial Affected
0.0
Industrial Affected
0.0
Residences Affected
10.0
Num Persons Hosp Not Ovnght
2.0
Num Injured Treated By Emt
0.0
Num Resident Building Affctd
10.0
Num Business Building Affctd
0.0
Accident Psig
56.0
Normal Psig
56.0
Mop Psig
60.0
Mop Cfr Section
192.619(A)(3)
Maop Established Date
2015-11-19 00:00:00
Accident Pressure
Pressure Did Not Exceed Maop
Gas Odorized System Type
Injection Pump
Gas Odorized Level
12.5
Scada In Place Ind
No
Accident Identifier
Notification From Emergency Responder
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Existing scada equipment would have given no indication of an issue at this location.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Pipe, Weld, Or Joint Failure
Cause Details
Fusion Joint
Pwjf Failure Type
Fusion Joint
Plastic Joint Subtype
Butt, Heat Fusion
Fpw Installed Year
2017
Fpw First Plastic Type
Polyethylene (Pe)
Fpw Second Plastic Type
Polyethylene (Pe)
Additional Lack Fusion Ind
Yes
Result Construction Ind
Yes
Result Construction Subtype
Poor Workmanship
Hydrotest Conducted Ind
No
Preparer Name
R***** R S****
Preparer Title
Manager Psms Technical Training
Preparer Email
R***********@n****.com
Preparer Telephone
5056973169
Authorizer Name
A***** M*******
Authorizer Title
Director Safety Pipeline Safety Tech Training
Authorizer Telephone
5056973518
Authorizer Email
A**************@n****.com
Narrative
On september 7, 2023, an explosion occurred at 14:18 at 4100 ridgeley ave ne in albuquerque, nm 87108. At 14:37, nmgc was notified by albuquerque fire and rescue of a house explosion. Nmgc arrived at the property at 14:52. Gas was escaping from the riser when the nmgc technician arrived. Gas was under control at 15:33 at the riser. Nmgc began probing for gas at 15:33. The nmgc responding crew discovered gas concentration readings of 100% gas in the street directly in front of 4100 ridgeley ave ne. Nmgc exposed the 2-inch pe pipe, where the section of main was offset with a dogleg that was installed in 2017. A 2x3-inch leak clamp was installed as a temporary repair. The section of main was squeezed off at 21:30 and capped as a permanent repair. There were two residents of 4100 ridgeley avenue who were treated for non-life threatening injuries and released. At 17:15, gas odorant testing with a heath odorometer was conducted revealing sufficient odorant at 0.50% gas-in-air (12.5% lel). Additional gas odorant testing with a heath odorometer was performed showing appropriate odorant levels. Laboratory tests were conducted on october 25, 2023 which revealed a lack of complete fusion on butt weld. Regarding questions part a #7 and part a #21c, the form does not allow an entry of "unknown" because a calculation cannot be performed due to limited or unknown information needed to perform the calculation.
Report Received Date 2023-10-06 00:00:00
Iyear 2023.0
Report Number 20230057.0
Supplemental Number 39364.0
Report Type Supplemental Final
Operator Id 6141 PHMSA Enforcement
Name New Mexico Gas Company
Operator Street Address 7120 Wyoming Blvd N.e. Suite 20
Operator City Name Albuquerque
Operator State Abbreviation NM
Operator Postal Code 87109.0
Time Zone Mountain
Daylight Savings Ind Yes
Location Street Address 4100 Ridgeley Dr Ne
Location City Name Albuquerque
Location County Name Bernalillo
Location State Abbreviation NM
Location Postal Code 87108.0
Location Latitude 35.08043 Google Maps OpenStreetMap
Location Longitude -106.598806 Google Maps OpenStreetMap
Flow Cont Squeeze Off Ind Yes
Flow Cont Other Ind Yes
Flow Cont Other Detail 2x3 Leak Clamp On Main And Plugged Off Riser
Nrc Rpt Num 1378470.0 NRC Report How to search
Additional Nrc Report Numbers 1378626.0
Commodity Released Type Natural Gas
Unintentional Release 1.0
Intentional Release 0.083
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Ignite Ind Yes
How Extinguished Other
How Extinguished Other Detail No Residual Fire After Initial Ignition Event.
Gas Consumed By Fire In Mcf 1
Explode Ind Yes
Num Pub Evacuated 19.0
Federal No
Location Type Public Property
Incident Area Type Underground
Incident Area Subtype Under Pavement
Depth Of Cover 45.0
Other Underground Facilities Yes
Crossing No
Pipe Facility Type Investor Owned
System Part Involved Main
Installation Year 2017.0
Manufactured Year 2017.0
Pipe Diameter 2.0
Pipe Specification Astm D2513
Pipe Manufacturer Performance Pipe
Material Involved Plastic
Plastic Type Polyethylene (Pe)
Plastic Sdr 11
Material Pe Pipe Code 4710
Release Type Leak
Leak Type Other
Leak Type Other Lack Of Complete Fusion
Class Location Type Class 3 Location
Est Cost Oper Paid 500000.0
Est Cost Prop Damage 0.0
Est Cost Emergency 11250.0
Est Cost Other 0.0
Gas Cost In Mcf 4.99
Est Cost Unintentional Release 5.0
Est Cost Intentional Release 0.0
Prpty 511255.0
Commercial Affected 0.0
Industrial Affected 0.0
Residences Affected 10.0
Num Persons Hosp Not Ovnght 2.0
Num Injured Treated By Emt 0.0
Num Resident Building Affctd 10.0
Num Business Building Affctd 0.0
Accident Psig 56.0
Normal Psig 56.0
Mop Psig 60.0
Mop Cfr Section 192.619(A)(3) View CFR 49 §192
Maop Established Date 2015-11-19 00:00:00
Accident Pressure Pressure Did Not Exceed Maop
Gas Odorized System Type Injection Pump
Gas Odorized Level 12.5
Scada In Place Ind No
Accident Identifier Notification From Emergency Responder
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details Existing scada equipment would have given no indication of an issue at this location.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Pipe, Weld, Or Joint Failure
Cause Details Fusion Joint
Pwjf Failure Type Fusion Joint
Plastic Joint Subtype Butt, Heat Fusion
Fpw Installed Year 2017
Fpw First Plastic Type Polyethylene (Pe)
Fpw Second Plastic Type Polyethylene (Pe)
Additional Lack Fusion Ind Yes
Result Construction Ind Yes
Result Construction Subtype Poor Workmanship
Hydrotest Conducted Ind No
Preparer Name R***** R S****
Preparer Title Manager Psms Technical Training
Preparer Email R***********@n****.com
Preparer Telephone 5056973169
Authorizer Name A***** M*******
Authorizer Title Director Safety Pipeline Safety Tech Training
Authorizer Telephone 5056973518
Authorizer Email A**************@n****.com
Narrative On september 7, 2023, an explosion occurred at 14:18 at 4100 ridgeley ave ne in albuquerque, nm 87108. At 14:37, nmgc was notified by albuquerque fire and rescue of a house explosion. Nmgc arrived at the property at 14:52. Gas was escaping from the riser when the nmgc technician arrived. Gas was under control at 15:33 at the riser. Nmgc began probing for gas at 15:33. The nmgc responding crew discovered gas concentration readings of 100% gas in the street directly in front of 4100 ridgeley ave ne. Nmgc exposed the 2-inch pe pipe, where the section of main was offset with a dogleg that was installed in 2017. A 2x3-inch leak clamp was installed as a temporary repair. The section of main was squeezed off at 21:30 and capped as a permanent repair. There were two residents of 4100 ridgeley avenue who were treated for non-life threatening injuries and released. At 17:15, gas odorant testing with a heath odorometer was conducted revealing sufficient odorant at 0.50% gas-in-air (12.5% lel). Additional gas odorant testing with a heath odorometer was performed showing appropriate odorant levels. Laboratory tests were conducted on october 25, 2023 which revealed a lack of complete fusion on butt weld. Regarding questions part a #7 and part a #21c, the form does not allow an entry of "unknown" because a calculation cannot be performed due to limited or unknown information needed to perform the calculation.