GTG incident on 2023-04-06 — TX

Operator
Texas Eastern Transmission, Lp (Spectra Energy Partners, Lp)
Cause
Corrosion Failure
Commodity
Natural Gas
Program
GTG
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$241,835
Incident datetime
2023-04-06 00:00 UTC
Report number
Location
TX
Narrative
On march 9, 2023, texas eastern transmission, l.P. (tetlp) was conducting an anomaly dig on line 14 clin-kosc vs-4, m.P. 356.89, when the crew identified indications of a leak (I.E., bubbling). A pin hole leak was confirmed with a soap solution at approximately 12:07 ct. At approximately 14:20 ct it was confirmed that repairs would likely exceed the PHMSA damage/repair threshold, and the event was subsequently called into the nrc at 14:47 ct. At approximately 16:50 ct the upstream valve was closed, and the downstream compressor station (clinton) was used to pull the pressure in the line down. At 18:10 ct the downstream valve was closed, and the line was then completely blown down to make the repair. The leaking pipe was cut out and replaced and the line was returned to service on march 12, 2023, 17:20 ct. The removed section was sent to a lab for further metallurgical analysis. Tetlp had assessed the line with an mfl-a tool in early 2021. The anomaly in question was reported as having a 66% depth and was issued a due date of april 30, 2023. Excavation began march 8, 2023, and during the dig process the anomaly was found to be leaking. Further excavation verified that a negative lead to the rectifier had come loose resulting an increased corrosion growth rate under the connection. 06/19/2023 there were no clear indications of a problem in either the rectifier readings or the test lead readings at the rectifier, and there was no additional corrosion damage in the area. The corrosion was concentrated under the loose negative ground bed lead where current was leaving the pipe and returning to the ground bed.
Detailed record list
Report Received Date
2023-04-06 00:00:00
Iyear
2023
Report Number
20230031
Supplemental Number
38186
Report Type
Supplemental Final
Operator Id
Name
Texas Eastern Transmission, Lp (Spectra Energy Partners, Lp)
Operator Street Address
915 North Eldridge Parkway
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77079
Time Zone
Central
Daylight Savings Ind
No
Location Latitude
Location Longitude
-89.78411587
Nrc Rpt Num
Additional Nrc Report Numbers
1362124
Commodity Released Type
Natural Gas
Unintentional Release
4.101
Intentional Release
13546.07
Accompanying Liquid
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Status When Identified
Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind
Yes
Communication State Fed Ind
Yes
Party Initiated Communication
Local/state/federal Emergency Responder
Ignite Ind
No
Upstream Action Taken
Valve Closure
Downstream Action Taken
Valve Closure
Num Pub Evacuated
0
On Off Shore
Onshore
Onshore State Abbreviation
Ms
Onshore Postal Code
39045
Onshore City Name
Not Within A Municipality
Onshore County Name
Madison
Designated Location
Milepost
Designated Name
356.89
Pipe Fac Name
Texas Eastern Transmission , Lp
Segment Name
Line 14/vs04 Clin-Kosc
Federal
Yes
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Exposed Due To Excavation
Depth Of Cover
24
Other Underground Facilities
No
Crossing
No
Pipe Facility Type
Interstate
System Part Involved
Onshore Pipeline, Including Valve Sites
Item Involved
Pipe
Pipe Type
Pipe Body
Pipe Diameter
30
Puddle Weld Ind
No
Pipe Wall Thickness
0.375
Pipe Smys
52000
Pipe Specification
Api-5l
Pipe Seam Type
Dsaw
Pipe Manufacturer
National Tube Works
Pipe Coating Type
Coal Tar
Coating Applied Ind
Unknown
Installation Year
1955
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Class Location Type
Class 1 Location
Could Be Hca
No
Pir Radius
633
Heat Damage Ind
No
Non Heat Damage Ind
No
Did Occur In Mca Ind
No
Est Cost Oper Paid
0
Est Cost Unintentional Release
10
Est Cost Intentional Release
34407
Est Cost Prop Damage
241835
Est Cost Emergency
500
Est Cost Other
0
Gas Cost In Mcf
2.54
Prpty
276752
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Wildlife Impact Ind
No
Accident Psig
836
Gas Flow In Pipe In Mcf
463330
Mop Psig
936
Mop Cfr Section
192.619(A)(1)
Maop Established Date
2013-02-04 00:00:00
Maop Reversal Flow Ind
Bi-Directional
Accident Pressure
Pressure Did Not Exceed Maop
Pressure Restriction Ind
No
Gas Required Odorized Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Length Segment Isolated
63624
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
Transmission System
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Contractor Working For The Operator
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The leak was not of a size large enough to be identified through scada.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Other Corrosion Ind
Yes
Corrosion Type Details
Negative Rectifier Header Lead Came Loose Resulting In Localized Corrosion Beneath The Connection.
Field Exam Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
1955
Shielding Evident
No
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Close Interval Survey Ind
Yes
Cp Annual Survey Year
2022
Close Interval Survey Year
2015
Prior Damage
No
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Cir Trn Wave Mgn Flx Lkg Ind
Yes
Geometry Deformation Ind
Yes
Emat Ind
Yes
Other Tool Tech Ind
Yes
Axial Recent Year
2021
Axial Rcnt Propul Method
Free Swimming
Axial Rcnt Attuned Detect
Metal Loss
Axial Rcnt Atnd Dtct Metal
High Resolution
Axial Previous Year
2014
Axial Prev Propul Method
Free Swimming
Axial Prev Attuned Detect
Metal Loss
Axial Prev Atnd Dtct Metal
High Resolution
Circ Wave Recent Year
2020
Circ Wv Rcnt Propul Method
Free Swimming
Circ Wv Rcnt Resolution
High Resolution
Geometry Recent Year
2022
Geometry Rcnt Propul Method
Free Swimming
Geometry Rcnt Resolution
High Resolution
Geometrt Rcnt Measur Cups
No Cups
Geometry Previous Year
2021
Geometry Prev Propul Method
Free Swimming
Geometry Prev Resolution
High Resolution
Geometrt Prev Measur Cups
No Cups
Emat Recent Year
2020
Emat Rcnt Propul Method
Free Swimming
Other Tool
Imu
Other Recent Year
2022
Other Rcnt Propul Method
Free Swimming
Other Previous Year
2021
Other Prev Propul Method
Free Swimming
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
1955
Hydrtst Most Rcnt Pressure
1266
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
M****** M******
Preparer Email
M**************@e*******.com
Preparer Telephone
6128056542
Authorizer Name
G***** W*****
Authorizer Title
Director Operational Excellence
Authorizer Telephone
7136275008
Authorizer Email
G*************@e*******.com
Narrative
On march 9, 2023, texas eastern transmission, l.P. (tetlp) was conducting an anomaly dig on line 14 clin-kosc vs-4, m.P. 356.89, when the crew identified indications of a leak (I.E., bubbling). A pin hole leak was confirmed with a soap solution at approximately 12:07 ct. At approximately 14:20 ct it was confirmed that repairs would likely exceed the PHMSA damage/repair threshold, and the event was subsequently called into the nrc at 14:47 ct. At approximately 16:50 ct the upstream valve was closed, and the downstream compressor station (clinton) was used to pull the pressure in the line down. At 18:10 ct the downstream valve was closed, and the line was then completely blown down to make the repair. The leaking pipe was cut out and replaced and the line was returned to service on march 12, 2023, 17:20 ct. The removed section was sent to a lab for further metallurgical analysis. Tetlp had assessed the line with an mfl-a tool in early 2021. The anomaly in question was reported as having a 66% depth and was issued a due date of april 30, 2023. Excavation began march 8, 2023, and during the dig process the anomaly was found to be leaking. Further excavation verified that a negative lead to the rectifier had come loose resulting an increased corrosion growth rate under the connection. 06/19/2023 there were no clear indications of a problem in either the rectifier readings or the test lead readings at the rectifier, and there was no additional corrosion damage in the area. The corrosion was concentrated under the loose negative ground bed lead where current was leaving the pipe and returning to the ground bed.
Report Received Date 2023-04-06 00:00:00
Iyear 2023
Report Number 20230031
Supplemental Number 38186
Report Type Supplemental Final
Operator Id 19235 PHMSA Enforcement
Name Texas Eastern Transmission, Lp (Spectra Energy Partners, Lp)
Operator Street Address 915 North Eldridge Parkway
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77079
Time Zone Central
Daylight Savings Ind No
Location Latitude 32.78925848 Google Maps OpenStreetMap
Location Longitude -89.78411587 Google Maps OpenStreetMap
Nrc Rpt Num 1361895 NRC Report How to search
Additional Nrc Report Numbers 1362124
Commodity Released Type Natural Gas
Unintentional Release 4.101
Intentional Release 13546.07
Accompanying Liquid 0
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Status When Identified Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind Yes
Communication State Fed Ind Yes
Party Initiated Communication Local/state/federal Emergency Responder
Ignite Ind No
Upstream Action Taken Valve Closure
Downstream Action Taken Valve Closure
Num Pub Evacuated 0
On Off Shore Onshore
Onshore State Abbreviation Ms
Onshore Postal Code 39045
Onshore City Name Not Within A Municipality
Onshore County Name Madison
Designated Location Milepost
Designated Name 356.89
Pipe Fac Name Texas Eastern Transmission , Lp
Segment Name Line 14/vs04 Clin-Kosc
Federal Yes
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Exposed Due To Excavation
Depth Of Cover 24
Other Underground Facilities No
Crossing No
Pipe Facility Type Interstate
System Part Involved Onshore Pipeline, Including Valve Sites
Item Involved Pipe
Pipe Type Pipe Body
Pipe Diameter 30
Puddle Weld Ind No
Pipe Wall Thickness 0.375
Pipe Smys 52000
Pipe Specification Api-5l
Pipe Seam Type Dsaw
Pipe Manufacturer National Tube Works
Pipe Coating Type Coal Tar
Coating Applied Ind Unknown
Installation Year 1955
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Class Location Type Class 1 Location
Could Be Hca No
Pir Radius 633
Heat Damage Ind No
Non Heat Damage Ind No
Did Occur In Mca Ind No
Est Cost Oper Paid 0
Est Cost Unintentional Release 10
Est Cost Intentional Release 34407
Est Cost Prop Damage 241835
Est Cost Emergency 500
Est Cost Other 0
Gas Cost In Mcf 2.54
Prpty 276752
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Wildlife Impact Ind No
Accident Psig 836
Gas Flow In Pipe In Mcf 463330
Mop Psig 936
Mop Cfr Section 192.619(A)(1) View CFR 49 §192
Maop Established Date 2013-02-04 00:00:00
Maop Reversal Flow Ind Bi-Directional
Accident Pressure Pressure Did Not Exceed Maop
Pressure Restriction Ind No
Gas Required Odorized Ind No
Upstream Valve Type Ind Manual
Downstream Valve Type Ind Manual
Length Segment Isolated 63624
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function Transmission System
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Contractor Working For The Operator
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details The leak was not of a size large enough to be identified through scada.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details External Corrosion
Internal External External Corrosion
Visual Exam Results Localized Pitting
Other Corrosion Ind Yes
Corrosion Type Details Negative Rectifier Header Lead Came Loose Resulting In Localized Corrosion Beneath The Connection.
Field Exam Basis Ind Yes
Underground Location Yes
Under Cathodic Protection Ind Yes
Cathodic Pro Start Year 1955
Shielding Evident No
Cathodic Survey Type Yes
Cp Annual Survey Ind Yes
Close Interval Survey Ind Yes
Cp Annual Survey Year 2022
Close Interval Survey Year 2015
Prior Damage No
Collected Data Ind Yes
Axial Magnetic Flx Lkg Ind Yes
Cir Trn Wave Mgn Flx Lkg Ind Yes
Geometry Deformation Ind Yes
Emat Ind Yes
Other Tool Tech Ind Yes
Axial Recent Year 2021
Axial Rcnt Propul Method Free Swimming
Axial Rcnt Attuned Detect Metal Loss
Axial Rcnt Atnd Dtct Metal High Resolution
Axial Previous Year 2014
Axial Prev Propul Method Free Swimming
Axial Prev Attuned Detect Metal Loss
Axial Prev Atnd Dtct Metal High Resolution
Circ Wave Recent Year 2020
Circ Wv Rcnt Propul Method Free Swimming
Circ Wv Rcnt Resolution High Resolution
Geometry Recent Year 2022
Geometry Rcnt Propul Method Free Swimming
Geometry Rcnt Resolution High Resolution
Geometrt Rcnt Measur Cups No Cups
Geometry Previous Year 2021
Geometry Prev Propul Method Free Swimming
Geometry Prev Resolution High Resolution
Geometrt Prev Measur Cups No Cups
Emat Recent Year 2020
Emat Rcnt Propul Method Free Swimming
Other Tool Imu
Other Recent Year 2022
Other Rcnt Propul Method Free Swimming
Other Previous Year 2021
Other Prev Propul Method Free Swimming
Has Hydrtst Conduc Before Ind Yes
Hydrtst Most Rcnt Year 1955
Hydrtst Most Rcnt Pressure 1266
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name M****** M******
Preparer Email M**************@e*******.com
Preparer Telephone 6128056542
Authorizer Name G***** W*****
Authorizer Title Director Operational Excellence
Authorizer Telephone 7136275008
Authorizer Email G*************@e*******.com
Narrative On march 9, 2023, texas eastern transmission, l.P. (tetlp) was conducting an anomaly dig on line 14 clin-kosc vs-4, m.P. 356.89, when the crew identified indications of a leak (I.E., bubbling). A pin hole leak was confirmed with a soap solution at approximately 12:07 ct. At approximately 14:20 ct it was confirmed that repairs would likely exceed the PHMSA damage/repair threshold, and the event was subsequently called into the nrc at 14:47 ct. At approximately 16:50 ct the upstream valve was closed, and the downstream compressor station (clinton) was used to pull the pressure in the line down. At 18:10 ct the downstream valve was closed, and the line was then completely blown down to make the repair. The leaking pipe was cut out and replaced and the line was returned to service on march 12, 2023, 17:20 ct. The removed section was sent to a lab for further metallurgical analysis. Tetlp had assessed the line with an mfl-a tool in early 2021. The anomaly in question was reported as having a 66% depth and was issued a due date of april 30, 2023. Excavation began march 8, 2023, and during the dig process the anomaly was found to be leaking. Further excavation verified that a negative lead to the rectifier had come loose resulting an increased corrosion growth rate under the connection. 06/19/2023 there were no clear indications of a problem in either the rectifier readings or the test lead readings at the rectifier, and there was no additional corrosion damage in the area. The corrosion was concentrated under the loose negative ground bed lead where current was leaving the pipe and returning to the ground bed.