Incident details
Operator, cause, commodity and consequences with raw source fields.
GTG incident on 2023-02-22 — TX
Operator
Acadian Gas Pipeline System
Cause
Equipment Failure
Commodity
Natural Gas
Program
GTG
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$325,000
Incident datetime
2023-02-22 00:00 UTC
Report number
Location
TX
Narrative
On january 26, 2023 at 11:00 central time (ct), enterprise operations received a call from a local fisherman of bubbles in little tensas bayou near our chico b pipeline in the atchafalaya basin. At 11:45 ct, operations personnel confirmed the bubbles in the water were near the chico b pipeline. On january 27, 2023 at 10:55 ct divers confirmed the leak from the chico b pipeline. The upstream and downstream manual valves were closed at 15:00 ct to isolate the leak area. Enterprise determined the event to be reportable to the nrc due to exceedance of repair cost on february 8, 2023 at 17:41 ct. An existing pipeline clamp was determined to be leaking. The clamp was removed and replaced with a new clamp. Revisions to part g6 equipment failure - sub-cause have been made changing from non-threaded connection to other equipment failure. Revisions to part h narrative have been made clarifying waterway with little tensas bayou.
Detailed record list
Report Received Date
2023-02-22 00:00:00
Iyear
2023
Report Number
20230020
Supplemental Number
37889
Report Type
Supplemental Final
Operator Id
Name
Acadian Gas Pipeline System
Operator Street Address
1100 Louisiana St.
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Time Zone
Central
Daylight Savings Ind
No
Location Latitude
29.896266
Location Longitude
-91.322753
Nrc Rpt Num
1359602
Additional Nrc Report Numbers
1359742
Commodity Released Type
Natural Gas
Unintentional Release
67
Intentional Release
21000
Accompanying Liquid
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Status When Identified
Normal Operation, Includes Pauses During Maintenance
Shutdown Due Accident Ind
Yes
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Ignite Ind
No
Upstream Action Taken
Valve Closure
Downstream Action Taken
Valve Closure
Num Pub Evacuated
0
On Off Shore
Onshore
Onshore State Abbreviation
La
Onshore Postal Code
70538
Onshore City Name
Belle River
Onshore County Name
St. Martin
Designated Location
Survey Station No.
Designated Name
1619+81
Pipe Fac Name
Chico B
Segment Name
307-0100
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
12
Other Underground Facilities
No
Crossing
No
Pipe Facility Type
Intrastate
System Part Involved
Onshore Pipeline, Including Valve Sites
Item Involved
Repair Sleeve Or Clamp
Installation Year
2013
Manufactured Year
2013
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Seal Or Packing
Class Location Type
Class 1 Location
Could Be Hca
No
Pir Radius
430
Heat Damage Ind
No
Non Heat Damage Ind
No
Did Occur In Mca Ind
No
Est Cost Oper Paid
0
Est Cost Unintentional Release
206
Est Cost Intentional Release
64680
Est Cost Prop Damage
325000
Est Cost Emergency
2000
Est Cost Other
0
Gas Cost In Mcf
3.08
Prpty
391886
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Wildlife Impact Ind
No
Accident Psig
840
Gas Flow In Pipe In Mcf
70
Mop Psig
970
Mop Cfr Section
192.619(A)(2)
Maop Established Date
1966-08-17 00:00:00
Maop Reversal Flow Ind
Bi-Directional
Accident Pressure
Pressure Did Not Exceed Maop
Pressure Restriction Ind
No
Gas Required Odorized Ind
No
Upstream Valve Type Ind
Manual
Downstream Valve Type Ind
Manual
Length Segment Isolated
89760
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
Transmission System
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Accident Identifier
Notification From Public
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
The controller(s) or control room were not contributing factors in this incident, this was a leaking clamp on the pipeline.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Other Equipment Failure
Eq Failure Type
Other Equipment Failure
Eq Failure Details
Plidco Clamp End Seal Failure.
Eq Additional Other Ind
Yes
Eq Additional Other Details
Plidco Clamp End Seal Failure
Preparer Name
N***** G***
Preparer Title
Senior Pipeline Compliance Specialist
Preparer Email
N****@e****.com
Preparer Telephone
985-493-4629
Local Contact Name
N***** G***
Local Contact Email
N****@e****.com
Local Contact Telephone
985-493-4629
Authorizer Name
N*** T*****
Authorizer Title
Senior Compliance Manager
Authorizer Telephone
713-381-2493
Authorizer Email
N*******@e****.com
Narrative
On january 26, 2023 at 11:00 central time (ct), enterprise operations received a call from a local fisherman of bubbles in little tensas bayou near our chico b pipeline in the atchafalaya basin. At 11:45 ct, operations personnel confirmed the bubbles in the water were near the chico b pipeline. On january 27, 2023 at 10:55 ct divers confirmed the leak from the chico b pipeline. The upstream and downstream manual valves were closed at 15:00 ct to isolate the leak area. Enterprise determined the event to be reportable to the nrc due to exceedance of repair cost on february 8, 2023 at 17:41 ct. An existing pipeline clamp was determined to be leaking. The clamp was removed and replaced with a new clamp. Revisions to part g6 equipment failure - sub-cause have been made changing from non-threaded connection to other equipment failure. Revisions to part h narrative have been made clarifying waterway with little tensas bayou.
Report Received Date | 2023-02-22 00:00:00 |
---|---|
Iyear | 2023 |
Report Number | 20230020 |
Supplemental Number | 37889 |
Report Type | Supplemental Final |
Operator Id | 3 PHMSA Enforcement |
Name | Acadian Gas Pipeline System |
Operator Street Address | 1100 Louisiana St. |
Operator City Name | Houston |
Operator State Abbreviation | TX |
Operator Postal Code | 77002 |
Time Zone | Central |
Daylight Savings Ind | No |
Location Latitude | 29.896266 Google Maps OpenStreetMap |
Location Longitude | -91.322753 Google Maps OpenStreetMap |
Nrc Rpt Num | 1359602 NRC Report How to search |
Additional Nrc Report Numbers | 1359742 |
Commodity Released Type | Natural Gas |
Unintentional Release | 67 |
Intentional Release | 21000 |
Accompanying Liquid | 0 |
Fatality Ind | No |
Fatal | 0 |
Injury Ind | No |
Injure | 0 |
Status When Identified | Normal Operation, Includes Pauses During Maintenance |
Shutdown Due Accident Ind | Yes |
Communication State Fed Ind | Yes |
Party Initiated Communication | Operator |
Ignite Ind | No |
Upstream Action Taken | Valve Closure |
Downstream Action Taken | Valve Closure |
Num Pub Evacuated | 0 |
On Off Shore | Onshore |
Onshore State Abbreviation | La |
Onshore Postal Code | 70538 |
Onshore City Name | Belle River |
Onshore County Name | St. Martin |
Designated Location | Survey Station No. |
Designated Name | 1619+81 |
Pipe Fac Name | Chico B |
Segment Name | 307-0100 |
Federal | No |
Location Type | Pipeline Right-Of-Way |
Incident Area Type | Underground |
Incident Area Subtype | Under Soil |
Depth Of Cover | 12 |
Other Underground Facilities | No |
Crossing | No |
Pipe Facility Type | Intrastate |
System Part Involved | Onshore Pipeline, Including Valve Sites |
Item Involved | Repair Sleeve Or Clamp |
Installation Year | 2013 |
Manufactured Year | 2013 |
Material Involved | Carbon Steel |
Release Type | Leak |
Leak Type | Seal Or Packing |
Class Location Type | Class 1 Location |
Could Be Hca | No |
Pir Radius | 430 |
Heat Damage Ind | No |
Non Heat Damage Ind | No |
Did Occur In Mca Ind | No |
Est Cost Oper Paid | 0 |
Est Cost Unintentional Release | 206 |
Est Cost Intentional Release | 64680 |
Est Cost Prop Damage | 325000 |
Est Cost Emergency | 2000 |
Est Cost Other | 0 |
Gas Cost In Mcf | 3.08 |
Prpty | 391886 |
Num Persons Hosp Not Ovnght | 0 |
Num Injured Treated By Emt | 0 |
Num Resident Building Affctd | 0 |
Num Business Building Affctd | 0 |
Wildlife Impact Ind | No |
Accident Psig | 840 |
Gas Flow In Pipe In Mcf | 70 |
Mop Psig | 970 |
Mop Cfr Section | 192.619(A)(2) View CFR 49 §192 |
Maop Established Date | 1966-08-17 00:00:00 |
Maop Reversal Flow Ind | Bi-Directional |
Accident Pressure | Pressure Did Not Exceed Maop |
Pressure Restriction Ind | No |
Gas Required Odorized Ind | No |
Upstream Valve Type Ind | Manual |
Downstream Valve Type Ind | Manual |
Length Segment Isolated | 89760 |
Internal Inspection Ind | Yes |
Operation Complications Ind | No |
Pipeline Function | Transmission System |
Scada In Place Ind | Yes |
Scada Operating Ind | Yes |
Scada Functional Ind | Yes |
Scada Detection Ind | No |
Scada Conf Ind | No |
Accident Identifier | Notification From Public |
Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
Investigation Status Details | The controller(s) or control room were not contributing factors in this incident, this was a leaking clamp on the pipeline. |
Employee Drug Test Ind | No |
Contractor Drug Test Ind | No |
Cause | Equipment Failure |
Cause Details | Other Equipment Failure |
Eq Failure Type | Other Equipment Failure |
Eq Failure Details | Plidco Clamp End Seal Failure. |
Eq Additional Other Ind | Yes |
Eq Additional Other Details | Plidco Clamp End Seal Failure |
Preparer Name | N***** G*** |
Preparer Title | Senior Pipeline Compliance Specialist |
Preparer Email | N****@e****.com |
Preparer Telephone | 985-493-4629 |
Local Contact Name | N***** G*** |
Local Contact Email | N****@e****.com |
Local Contact Telephone | 985-493-4629 |
Authorizer Name | N*** T***** |
Authorizer Title | Senior Compliance Manager |
Authorizer Telephone | 713-381-2493 |
Authorizer Email | N*******@e****.com |
Narrative | On january 26, 2023 at 11:00 central time (ct), enterprise operations received a call from a local fisherman of bubbles in little tensas bayou near our chico b pipeline in the atchafalaya basin. At 11:45 ct, operations personnel confirmed the bubbles in the water were near the chico b pipeline. On january 27, 2023 at 10:55 ct divers confirmed the leak from the chico b pipeline. The upstream and downstream manual valves were closed at 15:00 ct to isolate the leak area. Enterprise determined the event to be reportable to the nrc due to exceedance of repair cost on february 8, 2023 at 17:41 ct. An existing pipeline clamp was determined to be leaking. The clamp was removed and replaced with a new clamp. Revisions to part g6 equipment failure - sub-cause have been made changing from non-threaded connection to other equipment failure. Revisions to part h narrative have been made clarifying waterway with little tensas bayou. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA