HL incident on 2022-11-18 — KS

Operator
Flint Hills Resources, Lc
Cause
Material Failure Of Pipe Or Weld
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$11,800
Incident datetime
2022-11-18 14:45
Report number
Location
KS
Narrative
On 3/7/2023 flint hills resources changed the following: - part c question 6 - changed the leak type from "other" to "pinhole." - part d question 8 - estimated costs were updated to reflect actual costs to-date. The prior report included costs estimated at the time of the submittal. On 11/18/2022 flint hills resources was on site performing a scheduled maintenance dig. At approximately 14:45 the dig crew observed contaminated soil and notified the pipeline control center. At 15:01 the pipeline was shut down and the segment was isolated. A small through-wall defect was discovered at the location of the scheduled maintenance. The planned repair was completed utilizing a type-b sleeve, and the line was restarted at 16:53 on 11/18/2022.
Detailed record list
Report Received Date
2022-12-14 00:00:00
Iyear
2022
Report Number
20220283
Supplemental Number
37798
Report Type
Supplemental Final
Operator Id
Name
Flint Hills Resources, Lc
Operator Street Address
4111 East 37th Street North
Operator City Name
Wichita
Operator State Abbreviation
KS
Operator Postal Code
67220
Local Datetime
2022-11-18 14:45:00
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
0.5
Recovered Bbls
0.5
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Local Operating Personnel, Including Contractors
Operator Type
Operator Employee
Incident Identified Datetime
2022-11-18 14:45:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2022-11-18 15:01:00
Restart Datetime
2022-11-18 16:53:00
Communication State Fed Ind
No
On Site Datetime
2022-11-18 14:45:00
Confirmed Discovery Datetime
2022-11-18 14:45:00
Nrc Rpt Num
Nrc Notification Not Required
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2022-11-18 14:48:00
Upstream Valve Type Ind
Remotely Controlled
Downstream Action Taken
Valve Closure
Downstream Vlv Close Datetime
2022-11-18 15:01:00
Downstream Valve Type Ind
Remotely Controlled
Notify Qualified Indiv Ind
No
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Minnesota Pipeline Line / Line 1
Segment Name
Foley To Zimmerman / 5606
Onshore State Abbreviation
Mn
Onshore Postal Code
56329
Onshore City Name
Glendorado
Onshore County Name
Benton
Designated Location
Milepost
Designated Name
175
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Exposed Due To Excavation
Depth Of Cover
40
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Pipe
Pipe Type
Pipe Seam
Pipe Diameter
16
Pipe Wall Thickness
0.25
Pipe Smys
52000
Pipe Specification
Api 5lx
Pipe Seam Type
Erw - Low Frequency
Pipe Manufacturer
Youngstown Sheet And Tube
Pipe Coating Type
Coal Tar
Coating Applied Ind
No
Installation Year
1954
Manufactured Year
1954
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
Yes
Usa Drinking Ind
Yes
Usa Drinking Yes No
Yes
Est Cost Oper Paid
24821
Est Cost Gas Released
36
Est Cost Prop Damage
11800
Est Cost Emergency
0
Est Cost Environmental
0
Est Cost Other
0
Prpty
36657
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
475
Mop Psig
1170
Mop Cfr Section
Internal Design Pressure �195.406(A)(1)
Maop Established Date
2014-05-16 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
173977
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
It was determined that neither controller actions nor control room issues contributed to the accident.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Material Failure Of Pipe Or Weld
Cause Details
Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Field Exam Ind
Yes
Failure Type
Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Other Factor
Yes
Other Factor Details
Lack Of Fusion Of The Erw Seam
Additional Lack Fusion Ind
Yes
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Ultrasonic Ind
Yes
Geometry Deformation Ind
Yes
Other Tool Tech Ind
Yes
Axial Recent Year
2021
Axial Rcnt Propul Method
Free Swimming
Axial Rcnt Attuned Detect
Metal Loss
Axial Rcnt Atnd Dtct Metal
High Resolution
Axial Previous Year
2016
Axial Prev Propul Method
Free Swimming
Axial Prev Attuned Detect
Metal Loss
Axial Prev Atnd Dtct Metal
High Resolution
Ultrasonic Recent Year
2021
Ultrasonic Rcnt Propul Method
Free Swimming
Ultrasonic Rcnt Attuned
Crack
Ultr Previous Year
2020
Ultra Prev Propul Method
Free Swimming
Ultra Prev Attuned
Crack
Geometry Recent Year
2021
Geometry Rcnt Propul Method
Free Swimming
Geometry Rcnt Resolution
High Resolution
Geometrt Rcnt Measur Cups
No Cups
Geometry Previous Year
2016
Geometry Prev Propul Method
Free Swimming
Geometry Prev Resolution
High Resolution
Geometrt Prev Measur Cups
No Cups
Other Tool
Helical Mfl
Other Recent Year
2021
Other Rcnt Propul Method
Free Swimming
Other Previous Year
2016
Other Prev Propul Method
Free Swimming
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
2014
Hydrtst Most Rcnt Pressure
1541
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
M***** P****
Preparer Title
Compliance Managment Systems Specialist
Preparer Email
M***********@f**.com
Preparer Telephone
361-242-8781
Prepared Date
2023-03-07 00:00:00
Local Contact Name
K**** L*****
Local Contact Email
K***********@f**.com
Local Contact Telephone
316-708-0732
Authorizer Name
K**** L*****
Authorizer Telephone
316-708-0732
Authorizer Title
Compliance Specialist
Authorizer Email
K***********@f**.com
Narrative
On 3/7/2023 flint hills resources changed the following: - part c question 6 - changed the leak type from "other" to "pinhole." - part d question 8 - estimated costs were updated to reflect actual costs to-date. The prior report included costs estimated at the time of the submittal. On 11/18/2022 flint hills resources was on site performing a scheduled maintenance dig. At approximately 14:45 the dig crew observed contaminated soil and notified the pipeline control center. At 15:01 the pipeline was shut down and the segment was isolated. A small through-wall defect was discovered at the location of the scheduled maintenance. The planned repair was completed utilizing a type-b sleeve, and the line was restarted at 16:53 on 11/18/2022.
Report Received Date 2022-12-14 00:00:00
Iyear 2022
Report Number 20220283
Supplemental Number 37798
Report Type Supplemental Final
Operator Id 22855 PHMSA Enforcement
Name Flint Hills Resources, Lc
Operator Street Address 4111 East 37th Street North
Operator City Name Wichita
Operator State Abbreviation KS
Operator Postal Code 67220
Local Datetime 2022-11-18 14:45:00
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 45.57813909 Google Maps OpenStreetMap
Location Longitude -93.7924912 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 0.5
Recovered Bbls 0.5
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Local Operating Personnel, Including Contractors
Operator Type Operator Employee
Incident Identified Datetime 2022-11-18 14:45:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind Yes
Shutdown Datetime 2022-11-18 15:01:00
Restart Datetime 2022-11-18 16:53:00
Communication State Fed Ind No
On Site Datetime 2022-11-18 14:45:00
Confirmed Discovery Datetime 2022-11-18 14:45:00
Nrc Rpt Num Nrc Notification Not Required NRC Report How to search
Ignite Ind No
Upstream Action Taken Valve Closure
Upstream Valve Close Datetime 2022-11-18 14:48:00
Upstream Valve Type Ind Remotely Controlled
Downstream Action Taken Valve Closure
Downstream Vlv Close Datetime 2022-11-18 15:01:00
Downstream Valve Type Ind Remotely Controlled
Notify Qualified Indiv Ind No
Oil Spill Removal Org Ind No
Num Pub Evacuated 0
Pipe Fac Name Minnesota Pipeline Line / Line 1
Segment Name Foley To Zimmerman / 5606
Onshore State Abbreviation Mn
Onshore Postal Code 56329
Onshore City Name Glendorado
Onshore County Name Benton
Designated Location Milepost
Designated Name 175
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Exposed Due To Excavation
Depth Of Cover 40
Crossing No
Pipe Facility Type Interstate
Item Involved Pipe
Pipe Type Pipe Seam
Pipe Diameter 16
Pipe Wall Thickness 0.25
Pipe Smys 52000
Pipe Specification Api 5lx
Pipe Seam Type Erw - Low Frequency
Pipe Manufacturer Youngstown Sheet And Tube
Pipe Coating Type Coal Tar
Coating Applied Ind No
Installation Year 1954
Manufactured Year 1954
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind No
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca Yes
Usa Drinking Ind Yes
Usa Drinking Yes No Yes
Est Cost Oper Paid 24821
Est Cost Gas Released 36
Est Cost Prop Damage 11800
Est Cost Emergency 0
Est Cost Environmental 0
Est Cost Other 0
Prpty 36657
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 475
Mop Psig 1170
Mop Cfr Section Internal Design Pressure �195.406(A)(1) View CFR 49 §192
Maop Established Date 2014-05-16 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 173977
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind No
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind No
Cpm Conf Ind No
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details It was determined that neither controller actions nor control room issues contributed to the accident.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Material Failure Of Pipe Or Weld
Cause Details Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Field Exam Ind Yes
Failure Type Original Manufacturing-Related (Not Girth Weld Or Other Welds Formed In The Field)
Other Factor Yes
Other Factor Details Lack Of Fusion Of The Erw Seam
Additional Lack Fusion Ind Yes
Collected Data Ind Yes
Axial Magnetic Flx Lkg Ind Yes
Ultrasonic Ind Yes
Geometry Deformation Ind Yes
Other Tool Tech Ind Yes
Axial Recent Year 2021
Axial Rcnt Propul Method Free Swimming
Axial Rcnt Attuned Detect Metal Loss
Axial Rcnt Atnd Dtct Metal High Resolution
Axial Previous Year 2016
Axial Prev Propul Method Free Swimming
Axial Prev Attuned Detect Metal Loss
Axial Prev Atnd Dtct Metal High Resolution
Ultrasonic Recent Year 2021
Ultrasonic Rcnt Propul Method Free Swimming
Ultrasonic Rcnt Attuned Crack
Ultr Previous Year 2020
Ultra Prev Propul Method Free Swimming
Ultra Prev Attuned Crack
Geometry Recent Year 2021
Geometry Rcnt Propul Method Free Swimming
Geometry Rcnt Resolution High Resolution
Geometrt Rcnt Measur Cups No Cups
Geometry Previous Year 2016
Geometry Prev Propul Method Free Swimming
Geometry Prev Resolution High Resolution
Geometrt Prev Measur Cups No Cups
Other Tool Helical Mfl
Other Recent Year 2021
Other Rcnt Propul Method Free Swimming
Other Previous Year 2016
Other Prev Propul Method Free Swimming
Has Hydrtst Conduc Before Ind Yes
Hydrtst Most Rcnt Year 2014
Hydrtst Most Rcnt Pressure 1541
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name M***** P****
Preparer Title Compliance Managment Systems Specialist
Preparer Email M***********@f**.com
Preparer Telephone 361-242-8781
Prepared Date 2023-03-07 00:00:00
Local Contact Name K**** L*****
Local Contact Email K***********@f**.com
Local Contact Telephone 316-708-0732
Authorizer Name K**** L*****
Authorizer Telephone 316-708-0732
Authorizer Title Compliance Specialist
Authorizer Email K***********@f**.com
Narrative On 3/7/2023 flint hills resources changed the following: - part c question 6 - changed the leak type from "other" to "pinhole." - part d question 8 - estimated costs were updated to reflect actual costs to-date. The prior report included costs estimated at the time of the submittal. On 11/18/2022 flint hills resources was on site performing a scheduled maintenance dig. At approximately 14:45 the dig crew observed contaminated soil and notified the pipeline control center. At 15:01 the pipeline was shut down and the segment was isolated. A small through-wall defect was discovered at the location of the scheduled maintenance. The planned repair was completed utilizing a type-b sleeve, and the line was restarted at 16:53 on 11/18/2022.

All rights reserved. Copyright © by ClearPHMSA