Incident details
Operator, cause, commodity and consequences with raw source fields.
HL incident on 2022-11-14 — TX
Operator
Enterprise Products Operating Llc
Cause
Equipment Failure
Commodity
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$167,000
Incident datetime
2022-11-14 10:15
Report number
Location
TX
Narrative
On 11/14/2022 at 10:15 am cst, during station rounds, a pipeline technician found approximately 5 barrels of natural gasoline on the ground by lid220 scraper trap at tulia pump station. The pipeline segment was shutdown and isolated. On 11/15/2022 once the pipeline was excavated, a buried stopple fitting was found leaking. A laboratory failure analysis study of the stopple concluded that a crack had initiated at the weld root of the stopple fitting long seam weld, and the failure was due to fatigue growth in lack of penetration and lack of fusion defects. The pipeline was repaired and returned to service on 11/18/2022. This is an nrc reportable event due to the cost of repair exceeding $50,000. Initial call to nrc was made on 12/15/2022 at 12:35 ct (nrc# 1352631). The call was made based on repair cost estimates exceeding $50,000. 48hr update call to nrc was made on 12/17/2022 at 12:25 ct (nrc# 1352793). The update provided a product release amount of 200 barrels of natural gasoline.
Detailed record list
Report Received Date
2022-12-12 00:00:00
Iyear
2022
Report Number
20220280
Supplemental Number
37625
Report Type
Supplemental Final
Operator Id
31618
Name
Enterprise Products Operating Llc
Operator Street Address
1100 Louisiana Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2022-11-15 12:15:00
Time Zone
Central
Daylight Savings Ind
No
Location Latitude
34.64684
Location Longitude
-101.75889
Commodity Released Type
Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions
Commodity Subtype
Other Hvl
Commodity Details
Natural Gasoline
Unintentional Release Bbls
204.76
Intentional Release Bbls
0
Recovered Bbls
0
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Ground Patrol By Operator Or Its Contractor
Operator Type
Operator Employee
Incident Identified Datetime
2022-11-14 10:15:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2022-11-14 10:39:00
Restart Datetime
2022-11-18 10:56:00
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2022-11-14 11:30:00
On Site Datetime
2022-11-14 10:15:00
Confirmed Discovery Datetime
2022-11-14 10:15:00
Nrc Rpt Datetime
2022-11-15 12:35:00
Nrc Rpt Num
1352631
Additional Nrc Report Numbers
1352793
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2022-11-14 10:34:00
Upstream Valve Type Ind
Remotely Controlled
Downstream Action Taken
Valve Closure
Downstream Vlv Close Datetime
2022-11-14 11:06:00
Downstream Valve Type Ind
Manual
Num Pub Evacuated
0
Pipe Fac Name
Tulia Pump Station
Segment Name
Lid220
Onshore State Abbreviation
Tx
Onshore Postal Code
79088
Onshore City Name
Not Within A Municipality
Onshore County Name
Swisher
Designated Location
Milepost
Designated Name
152.2
Federal
No
Location Type
Totally Contained On Operator-Controlled Property
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
48
Crossing
No
Pipe Facility Type
Interstate
Item Involved
Tap Fitting(Stopple, Thread-O-Ring, Weld-O-Let, Etc.)
Installation Year
1971
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Crack
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
No
Water Contam Ind
No
Could Be Hca
No
Commodity Reached Hca
No
Est Cost Oper Paid
800
Est Cost Gas Released
12000
Est Cost Prop Damage
167000
Est Cost Emergency
15000
Est Cost Environmental
8500
Est Cost Other
15900
Est Cost Other Details
Failure Analysis Study And Report
Prpty
219200
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
691
Mop Psig
1309
Mop Cfr Section
Internal Design Pressure �195.406(A)(1)
Maop Established Date
1972-05-01 00:00:00
Maop Reversal Flow Ind
Bi-Directional
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
81840
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
No
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
No
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
Pipeline control operator did not contribute to the leak.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Equipment Failure
Cause Details
Malfunction Of Control/relief Equipment
Eq Failure Type
Malfunction Of Control/relief Equipment
Stopple Control Fitting Ind
Yes
Eq Additional Other Ind
Yes
Eq Additional Other Details
Fatigue Growth Of Lack Of Penetration And Lack Of Fusion Defects At Stopple Weld
Preparer Name
H*** D***
Preparer Title
Sr. Transportation Compliance Engineer
Preparer Email
H****@e****.com
Preparer Telephone
713-381-4277
Prepared Date
2023-01-25 00:00:00
Local Contact Name
H*** D***
Local Contact Email
H****@e****.com
Local Contact Telephone
713-381-4277
Authorizer Name
H*** D***
Authorizer Telephone
713-381-4277
Authorizer Title
Sr. Transportation Compliance Engineer
Authorizer Email
H****@e****.com
Narrative
On 11/14/2022 at 10:15 am cst, during station rounds, a pipeline technician found approximately 5 barrels of natural gasoline on the ground by lid220 scraper trap at tulia pump station. The pipeline segment was shutdown and isolated. On 11/15/2022 once the pipeline was excavated, a buried stopple fitting was found leaking. A laboratory failure analysis study of the stopple concluded that a crack had initiated at the weld root of the stopple fitting long seam weld, and the failure was due to fatigue growth in lack of penetration and lack of fusion defects. The pipeline was repaired and returned to service on 11/18/2022. This is an nrc reportable event due to the cost of repair exceeding $50,000. Initial call to nrc was made on 12/15/2022 at 12:35 ct (nrc# 1352631). The call was made based on repair cost estimates exceeding $50,000. 48hr update call to nrc was made on 12/17/2022 at 12:25 ct (nrc# 1352793). The update provided a product release amount of 200 barrels of natural gasoline.
| Report Received Date | 2022-12-12 00:00:00 |
|---|---|
| Iyear | 2022 |
| Report Number | 20220280 |
| Supplemental Number | 37625 |
| Report Type | Supplemental Final |
| Operator Id | 31618 PHMSA Enforcement |
| Name | Enterprise Products Operating Llc |
| Operator Street Address | 1100 Louisiana Street |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2022-11-15 12:15:00 |
| Time Zone | Central |
| Daylight Savings Ind | No |
| Location Latitude | 34.64684 Google Maps OpenStreetMap |
| Location Longitude | -101.75889 Google Maps OpenStreetMap |
| Commodity Released Type | Hvl Or Other Flammable Or Toxic Fluid Which Is A Gas At Ambient Conditions |
| Commodity Subtype | Other Hvl |
| Commodity Details | Natural Gasoline |
| Unintentional Release Bbls | 204.76 |
| Intentional Release Bbls | 0 |
| Recovered Bbls | 0 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Ground Patrol By Operator Or Its Contractor |
| Operator Type | Operator Employee |
| Incident Identified Datetime | 2022-11-14 10:15:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Status When Identified | Normal Operation, Includes Pauses Between Batches And During Maintenance |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2022-11-14 10:39:00 |
| Restart Datetime | 2022-11-18 10:56:00 |
| Communication State Fed Ind | Yes |
| Party Initiated Communication | Operator |
| Initial Responder Com Datetime | 2022-11-14 11:30:00 |
| On Site Datetime | 2022-11-14 10:15:00 |
| Confirmed Discovery Datetime | 2022-11-14 10:15:00 |
| Nrc Rpt Datetime | 2022-11-15 12:35:00 |
| Nrc Rpt Num | 1352631 NRC Report How to search |
| Additional Nrc Report Numbers | 1352793 |
| Ignite Ind | No |
| Upstream Action Taken | Valve Closure |
| Upstream Valve Close Datetime | 2022-11-14 10:34:00 |
| Upstream Valve Type Ind | Remotely Controlled |
| Downstream Action Taken | Valve Closure |
| Downstream Vlv Close Datetime | 2022-11-14 11:06:00 |
| Downstream Valve Type Ind | Manual |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Tulia Pump Station |
| Segment Name | Lid220 |
| Onshore State Abbreviation | Tx |
| Onshore Postal Code | 79088 |
| Onshore City Name | Not Within A Municipality |
| Onshore County Name | Swisher |
| Designated Location | Milepost |
| Designated Name | 152.2 |
| Federal | No |
| Location Type | Totally Contained On Operator-Controlled Property |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 48 |
| Crossing | No |
| Pipe Facility Type | Interstate |
| Item Involved | Tap Fitting(Stopple, Thread-O-Ring, Weld-O-Let, Etc.) |
| Installation Year | 1971 |
| Manufactured Year | Unknown |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Crack |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | No |
| Water Contam Ind | No |
| Could Be Hca | No |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 800 |
| Est Cost Gas Released | 12000 |
| Est Cost Prop Damage | 167000 |
| Est Cost Emergency | 15000 |
| Est Cost Environmental | 8500 |
| Est Cost Other | 15900 |
| Est Cost Other Details | Failure Analysis Study And Report |
| Prpty | 219200 |
| Num Persons Hosp Not Ovnght | 0 |
| Num Injured Treated By Emt | 0 |
| Num Resident Building Affctd | 0 |
| Num Business Building Affctd | 0 |
| Accident Psig | 691 |
| Mop Psig | 1309 |
| Mop Cfr Section | Internal Design Pressure �195.406(A)(1) View CFR 49 §192 |
| Maop Established Date | 1972-05-01 00:00:00 |
| Maop Reversal Flow Ind | Bi-Directional |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | 81840 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | No |
| Cpm In Place Ind | Yes |
| Cpm Operating Ind | Yes |
| Cpm Functional Ind | Yes |
| Cpm Detection Ind | No |
| Cpm Conf Ind | No |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | Pipeline control operator did not contribute to the leak. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Equipment Failure |
| Cause Details | Malfunction Of Control/relief Equipment |
| Eq Failure Type | Malfunction Of Control/relief Equipment |
| Stopple Control Fitting Ind | Yes |
| Eq Additional Other Ind | Yes |
| Eq Additional Other Details | Fatigue Growth Of Lack Of Penetration And Lack Of Fusion Defects At Stopple Weld |
| Preparer Name | H*** D*** |
| Preparer Title | Sr. Transportation Compliance Engineer |
| Preparer Email | H****@e****.com |
| Preparer Telephone | 713-381-4277 |
| Prepared Date | 2023-01-25 00:00:00 |
| Local Contact Name | H*** D*** |
| Local Contact Email | H****@e****.com |
| Local Contact Telephone | 713-381-4277 |
| Authorizer Name | H*** D*** |
| Authorizer Telephone | 713-381-4277 |
| Authorizer Title | Sr. Transportation Compliance Engineer |
| Authorizer Email | H****@e****.com |
| Narrative | On 11/14/2022 at 10:15 am cst, during station rounds, a pipeline technician found approximately 5 barrels of natural gasoline on the ground by lid220 scraper trap at tulia pump station. The pipeline segment was shutdown and isolated. On 11/15/2022 once the pipeline was excavated, a buried stopple fitting was found leaking. A laboratory failure analysis study of the stopple concluded that a crack had initiated at the weld root of the stopple fitting long seam weld, and the failure was due to fatigue growth in lack of penetration and lack of fusion defects. The pipeline was repaired and returned to service on 11/18/2022. This is an nrc reportable event due to the cost of repair exceeding $50,000. Initial call to nrc was made on 12/15/2022 at 12:35 ct (nrc# 1352631). The call was made based on repair cost estimates exceeding $50,000. 48hr update call to nrc was made on 12/17/2022 at 12:25 ct (nrc# 1352793). The update provided a product release amount of 200 barrels of natural gasoline. |