HL incident on 2022-10-10 — TX

Operator
Sunoco Pipeline L.p.
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities 0 injuries
Property damage (nominal)
$0
Incident datetime
2022-10-10 18:30
Report number
Location
TX
Narrative
On 10/10/2022 at 18:00, a farmer called in an approximate 20'x20' stain on the surface of the row. The control center shutdown the pipeline and operations local operations team was dispatched to the area and conducted a row inspection. The crew discovered a leak on the 12-inch corsicana to tyler line. Approximately 400 barrels of crude oil was released. The segment was isolated by closing manual block valves. The area was excavated and the leak source identified and examined it was determined the failure was caused from an external corrosion pinhole. A mechanical plidco clamp was installed at 21:35. On 10/13, the torque on clamp was re-verified and the line was restarted at 20:30. Cathodic protection potentials in the area were above required criteria. The most recent in line assessment identified external metal loss at the failure point below actionable levels. Updated information was supplied to the tool vendor and the run was regraded and is currently being revalidated. The pipeline is currently on a shortened integrity assessment frequency in order to more closely monitor corrosion growth rates. The failed section of pipe has been cut out and replaced.
Detailed record list
Report Received Date
2022-11-09 00:00:00
Iyear
2022
Report Number
20220250
Supplemental Number
37716
Report Type
Supplemental Final
Operator Id
Name
Sunoco Pipeline L.p.
Operator Street Address
1300 Main Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2022-10-10 18:00:00
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
Location Longitude
Commodity Released Type
Crude Oil
Unintentional Release Bbls
400
Recovered Bbls
400
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Public
Incident Identified Datetime
2022-10-10 18:30:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2022-10-10 18:00:00
Restart Datetime
2022-10-13 20:30:00
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2022-10-10 19:35:00
On Site Datetime
2022-10-10 18:30:00
Confirmed Discovery Datetime
2022-10-10 18:30:00
Nrc Rpt Datetime
2022-10-10 19:11:00
Nrc Rpt Num
Additional Nrc Report Numbers
1349728
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2022-10-10 18:45:00
Upstream Valve Type Ind
Manual
Downstream Action Taken
Valve Closure
Downstream Vlv Close Datetime
2022-10-10 18:55:00
Downstream Valve Type Ind
Manual
Notify Qualified Indiv Ind
Yes
Qualified Indiv Notif Datetime
2022-10-10 18:05:00
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Corsicana To Tyler
Segment Name
26007 - 12-Inch Corsicana To Tyler Junction
Onshore State Abbreviation
Tx
Onshore Postal Code
75110
Onshore City Name
Not Within A Municipality
Onshore County Name
Navarro
Designated Location
Milepost
Designated Name
84.5
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
10
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Body
Puddle Weld Ind
No
Pipe Diameter
12.75
Pipe Wall Thickness
0.25
Pipe Smys
30000
Pipe Specification
Grade A
Pipe Seam Type
Single Saw
Pipe Manufacturer
Unknown
Pipe Coating Type
Coal Tar
Coating Applied Ind
No
Installation Year
1931
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
No
Est Cost Oper Paid
100000
Est Cost Gas Released
36800
Est Cost Prop Damage
0
Est Cost Emergency
21800
Est Cost Environmental
250000
Est Cost Other
0
Prpty
408600
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
350
Mop Psig
784
Mop Cfr Section
Subpart E Pressure Test �195.406(A)(3)
Maop Established Date
2013-03-27 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
56216
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
Yes
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
Yes
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
A review of the accident determined that there were no control room actions that contributed to the event.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Galvanic Corrosion Ind
Yes
Field Exam Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
1952
Shielding Evident
No
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Close Interval Survey Ind
Yes
Cp Annual Survey Year
2022
Close Interval Survey Year
2019
Prior Damage
N/a Bare/ineffectively Coated Pipe
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Geometry Deformation Ind
Yes
Axial Recent Year
2022
Axial Rcnt Propul Method
Free Swimming
Axial Rcnt Attuned Detect
Metal Loss
Axial Rcnt Atnd Dtct Metal
Standard Resolution
Axial Previous Year
2020
Axial Prev Propul Method
Free Swimming
Axial Prev Attuned Detect
Metal Loss
Axial Prev Atnd Dtct Metal
Standard Resolution
Geometry Recent Year
2022
Geometry Rcnt Propul Method
Free Swimming
Geometry Rcnt Resolution
Standard Resolution
Geometrt Rcnt Measur Cups
Inside Ili Cups
Geometry Previous Year
2020
Geometry Prev Propul Method
Free Swimming
Geometry Prev Resolution
Standard Resolution
Geometrt Prev Measur Cups
Inside Ili Cups
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
2013
Hydrtst Most Rcnt Pressure
1054
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
T*** N*******
Preparer Title
Director - Regulatory Compliance
Preparer Email
T************@e*************.com
Preparer Telephone
713-989-7126
Prepared Date
2023-02-15 00:00:00
Authorizer Name
T*** N*******
Authorizer Telephone
713-989-7126
Authorizer Title
Director - Regulatory Compliance
Authorizer Email
T************@e*************.com
Narrative
On 10/10/2022 at 18:00, a farmer called in an approximate 20'x20' stain on the surface of the row. The control center shutdown the pipeline and operations local operations team was dispatched to the area and conducted a row inspection. The crew discovered a leak on the 12-inch corsicana to tyler line. Approximately 400 barrels of crude oil was released. The segment was isolated by closing manual block valves. The area was excavated and the leak source identified and examined it was determined the failure was caused from an external corrosion pinhole. A mechanical plidco clamp was installed at 21:35. On 10/13, the torque on clamp was re-verified and the line was restarted at 20:30. Cathodic protection potentials in the area were above required criteria. The most recent in line assessment identified external metal loss at the failure point below actionable levels. Updated information was supplied to the tool vendor and the run was regraded and is currently being revalidated. The pipeline is currently on a shortened integrity assessment frequency in order to more closely monitor corrosion growth rates. The failed section of pipe has been cut out and replaced.
Report Received Date 2022-11-09 00:00:00
Iyear 2022
Report Number 20220250
Supplemental Number 37716
Report Type Supplemental Final
Operator Id 18718 PHMSA Enforcement
Name Sunoco Pipeline L.p.
Operator Street Address 1300 Main Street
Operator City Name Houston
Operator State Abbreviation TX
Operator Postal Code 77002
Local Datetime 2022-10-10 18:00:00
Time Zone Central
Daylight Savings Ind Yes
Location Latitude 32.103628 Google Maps OpenStreetMap
Location Longitude -96.280635 Google Maps OpenStreetMap
Commodity Released Type Crude Oil
Unintentional Release Bbls 400
Recovered Bbls 400
Fatality Ind No
Fatal 0
Injury Ind No
Injure 0
Accident Identifier Notification From Public
Incident Identified Datetime 2022-10-10 18:30:00
System Part Involved Onshore Pipeline, Including Valve Sites
On Off Shore Onshore
Status When Identified Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind Yes
Shutdown Datetime 2022-10-10 18:00:00
Restart Datetime 2022-10-13 20:30:00
Communication State Fed Ind Yes
Party Initiated Communication Operator
Initial Responder Com Datetime 2022-10-10 19:35:00
On Site Datetime 2022-10-10 18:30:00
Confirmed Discovery Datetime 2022-10-10 18:30:00
Nrc Rpt Datetime 2022-10-10 19:11:00
Nrc Rpt Num 1349534 NRC Report How to search
Additional Nrc Report Numbers 1349728
Ignite Ind No
Upstream Action Taken Valve Closure
Upstream Valve Close Datetime 2022-10-10 18:45:00
Upstream Valve Type Ind Manual
Downstream Action Taken Valve Closure
Downstream Vlv Close Datetime 2022-10-10 18:55:00
Downstream Valve Type Ind Manual
Notify Qualified Indiv Ind Yes
Qualified Indiv Notif Datetime 2022-10-10 18:05:00
Oil Spill Removal Org Ind No
Num Pub Evacuated 0
Pipe Fac Name Corsicana To Tyler
Segment Name 26007 - 12-Inch Corsicana To Tyler Junction
Onshore State Abbreviation Tx
Onshore Postal Code 75110
Onshore City Name Not Within A Municipality
Onshore County Name Navarro
Designated Location Milepost
Designated Name 84.5
Federal No
Location Type Pipeline Right-Of-Way
Incident Area Type Underground
Incident Area Subtype Under Soil
Depth Of Cover 10
Crossing No
Pipe Facility Type Intrastate
Item Involved Pipe
Pipe Type Pipe Body
Puddle Weld Ind No
Pipe Diameter 12.75
Pipe Wall Thickness 0.25
Pipe Smys 30000
Pipe Specification Grade A
Pipe Seam Type Single Saw
Pipe Manufacturer Unknown
Pipe Coating Type Coal Tar
Coating Applied Ind No
Installation Year 1931
Manufactured Year Unknown
Material Involved Carbon Steel
Release Type Leak
Leak Type Pinhole
Wildlife Impact Ind No
Soil Contamination Yes
Long Term Assessment No
Remediation Ind Yes
Soil Remed Ind Yes
Water Contam Ind No
Could Be Hca Yes
Commodity Reached Hca No
Est Cost Oper Paid 100000
Est Cost Gas Released 36800
Est Cost Prop Damage 0
Est Cost Emergency 21800
Est Cost Environmental 250000
Est Cost Other 0
Prpty 408600
Num Persons Hosp Not Ovnght 0
Num Injured Treated By Emt 0
Num Resident Building Affctd 0
Num Business Building Affctd 0
Accident Psig 350
Mop Psig 784
Mop Cfr Section Subpart E Pressure Test �195.406(A)(3) View CFR 49 §192
Maop Established Date 2013-03-27 00:00:00
Maop Reversal Flow Ind No
Accident Pressure Pressure Did Not Exceed Mop
Pressure Restriction Ind No
Length Segment Isolated 56216
Internal Inspection Ind Yes
Operation Complications Ind No
Pipeline Function > 20% Smys Regulated Transmission
Scada In Place Ind Yes
Scada Operating Ind Yes
Scada Functional Ind Yes
Scada Detection Ind No
Scada Conf Ind Yes
Cpm In Place Ind Yes
Cpm Operating Ind Yes
Cpm Functional Ind Yes
Cpm Detection Ind No
Cpm Conf Ind Yes
Investigation Status No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details A review of the accident determined that there were no control room actions that contributed to the event.
Employee Drug Test Ind No
Contractor Drug Test Ind No
Cause Corrosion Failure
Cause Details External Corrosion
Internal External External Corrosion
Visual Exam Results Localized Pitting
Galvanic Corrosion Ind Yes
Field Exam Basis Ind Yes
Underground Location Yes
Under Cathodic Protection Ind Yes
Cathodic Pro Start Year 1952
Shielding Evident No
Cathodic Survey Type Yes
Cp Annual Survey Ind Yes
Close Interval Survey Ind Yes
Cp Annual Survey Year 2022
Close Interval Survey Year 2019
Prior Damage N/a Bare/ineffectively Coated Pipe
Collected Data Ind Yes
Axial Magnetic Flx Lkg Ind Yes
Geometry Deformation Ind Yes
Axial Recent Year 2022
Axial Rcnt Propul Method Free Swimming
Axial Rcnt Attuned Detect Metal Loss
Axial Rcnt Atnd Dtct Metal Standard Resolution
Axial Previous Year 2020
Axial Prev Propul Method Free Swimming
Axial Prev Attuned Detect Metal Loss
Axial Prev Atnd Dtct Metal Standard Resolution
Geometry Recent Year 2022
Geometry Rcnt Propul Method Free Swimming
Geometry Rcnt Resolution Standard Resolution
Geometrt Rcnt Measur Cups Inside Ili Cups
Geometry Previous Year 2020
Geometry Prev Propul Method Free Swimming
Geometry Prev Resolution Standard Resolution
Geometrt Prev Measur Cups Inside Ili Cups
Has Hydrtst Conduc Before Ind Yes
Hydrtst Most Rcnt Year 2013
Hydrtst Most Rcnt Pressure 1054
Direct Asmnt Conducted No
Non Destructive Exam Ind No
Preparer Name T*** N*******
Preparer Title Director - Regulatory Compliance
Preparer Email T************@e*************.com
Preparer Telephone 713-989-7126
Prepared Date 2023-02-15 00:00:00
Authorizer Name T*** N*******
Authorizer Telephone 713-989-7126
Authorizer Title Director - Regulatory Compliance
Authorizer Email T************@e*************.com
Narrative On 10/10/2022 at 18:00, a farmer called in an approximate 20'x20' stain on the surface of the row. The control center shutdown the pipeline and operations local operations team was dispatched to the area and conducted a row inspection. The crew discovered a leak on the 12-inch corsicana to tyler line. Approximately 400 barrels of crude oil was released. The segment was isolated by closing manual block valves. The area was excavated and the leak source identified and examined it was determined the failure was caused from an external corrosion pinhole. A mechanical plidco clamp was installed at 21:35. On 10/13, the torque on clamp was re-verified and the line was restarted at 20:30. Cathodic protection potentials in the area were above required criteria. The most recent in line assessment identified external metal loss at the failure point below actionable levels. Updated information was supplied to the tool vendor and the run was regraded and is currently being revalidated. The pipeline is currently on a shortened integrity assessment frequency in order to more closely monitor corrosion growth rates. The failed section of pipe has been cut out and replaced.