HL incident on 2022-10-10 — TX
Operator
Sunoco Pipeline L.p.
Cause
Corrosion Failure
Commodity
Crude Oil
Program
HL
Damage and Injuries
0 fatalities
0 injuries
Property damage (nominal)
$0
Incident datetime
2022-10-10 18:30
Report number
Location
TX
Narrative
On 10/10/2022 at 18:00, a farmer called in an approximate 20'x20' stain on the surface of the row. The control center shutdown the pipeline and operations local operations team was dispatched to the area and conducted a row inspection. The crew discovered a leak on the 12-inch corsicana to tyler line. Approximately 400 barrels of crude oil was released. The segment was isolated by closing manual block valves. The area was excavated and the leak source identified and examined it was determined the failure was caused from an external corrosion pinhole. A mechanical plidco clamp was installed at 21:35. On 10/13, the torque on clamp was re-verified and the line was restarted at 20:30. Cathodic protection potentials in the area were above required criteria. The most recent in line assessment identified external metal loss at the failure point below actionable levels. Updated information was supplied to the tool vendor and the run was regraded and is currently being revalidated. The pipeline is currently on a shortened integrity assessment frequency in order to more closely monitor corrosion growth rates. The failed section of pipe has been cut out and replaced.
Detailed record list
Report Received Date
2022-11-09 00:00:00
Iyear
2022
Report Number
20220250
Supplemental Number
37716
Report Type
Supplemental Final
Operator Id
18718
Name
Sunoco Pipeline L.p.
Operator Street Address
1300 Main Street
Operator City Name
Houston
Operator State Abbreviation
TX
Operator Postal Code
77002
Local Datetime
2022-10-10 18:00:00
Time Zone
Central
Daylight Savings Ind
Yes
Location Latitude
32.103628
Location Longitude
-96.280635
Commodity Released Type
Crude Oil
Unintentional Release Bbls
400
Recovered Bbls
400
Fatality Ind
No
Fatal
0
Injury Ind
No
Injure
0
Accident Identifier
Notification From Public
Incident Identified Datetime
2022-10-10 18:30:00
System Part Involved
Onshore Pipeline, Including Valve Sites
On Off Shore
Onshore
Status When Identified
Normal Operation, Includes Pauses Between Batches And During Maintenance
Shutdown Due Accident Ind
Yes
Shutdown Datetime
2022-10-10 18:00:00
Restart Datetime
2022-10-13 20:30:00
Communication State Fed Ind
Yes
Party Initiated Communication
Operator
Initial Responder Com Datetime
2022-10-10 19:35:00
On Site Datetime
2022-10-10 18:30:00
Confirmed Discovery Datetime
2022-10-10 18:30:00
Nrc Rpt Datetime
2022-10-10 19:11:00
Nrc Rpt Num
1349534
Additional Nrc Report Numbers
1349728
Ignite Ind
No
Upstream Action Taken
Valve Closure
Upstream Valve Close Datetime
2022-10-10 18:45:00
Upstream Valve Type Ind
Manual
Downstream Action Taken
Valve Closure
Downstream Vlv Close Datetime
2022-10-10 18:55:00
Downstream Valve Type Ind
Manual
Notify Qualified Indiv Ind
Yes
Qualified Indiv Notif Datetime
2022-10-10 18:05:00
Oil Spill Removal Org Ind
No
Num Pub Evacuated
0
Pipe Fac Name
Corsicana To Tyler
Segment Name
26007 - 12-Inch Corsicana To Tyler Junction
Onshore State Abbreviation
Tx
Onshore Postal Code
75110
Onshore City Name
Not Within A Municipality
Onshore County Name
Navarro
Designated Location
Milepost
Designated Name
84.5
Federal
No
Location Type
Pipeline Right-Of-Way
Incident Area Type
Underground
Incident Area Subtype
Under Soil
Depth Of Cover
10
Crossing
No
Pipe Facility Type
Intrastate
Item Involved
Pipe
Pipe Type
Pipe Body
Puddle Weld Ind
No
Pipe Diameter
12.75
Pipe Wall Thickness
0.25
Pipe Smys
30000
Pipe Specification
Grade A
Pipe Seam Type
Single Saw
Pipe Manufacturer
Unknown
Pipe Coating Type
Coal Tar
Coating Applied Ind
No
Installation Year
1931
Manufactured Year
Unknown
Material Involved
Carbon Steel
Release Type
Leak
Leak Type
Pinhole
Wildlife Impact Ind
No
Soil Contamination
Yes
Long Term Assessment
No
Remediation Ind
Yes
Soil Remed Ind
Yes
Water Contam Ind
No
Could Be Hca
Yes
Commodity Reached Hca
No
Est Cost Oper Paid
100000
Est Cost Gas Released
36800
Est Cost Prop Damage
0
Est Cost Emergency
21800
Est Cost Environmental
250000
Est Cost Other
0
Prpty
408600
Num Persons Hosp Not Ovnght
0
Num Injured Treated By Emt
0
Num Resident Building Affctd
0
Num Business Building Affctd
0
Accident Psig
350
Mop Psig
784
Mop Cfr Section
Subpart E Pressure Test �195.406(A)(3)
Maop Established Date
2013-03-27 00:00:00
Maop Reversal Flow Ind
No
Accident Pressure
Pressure Did Not Exceed Mop
Pressure Restriction Ind
No
Length Segment Isolated
56216
Internal Inspection Ind
Yes
Operation Complications Ind
No
Pipeline Function
> 20% Smys Regulated Transmission
Scada In Place Ind
Yes
Scada Operating Ind
Yes
Scada Functional Ind
Yes
Scada Detection Ind
No
Scada Conf Ind
Yes
Cpm In Place Ind
Yes
Cpm Operating Ind
Yes
Cpm Functional Ind
Yes
Cpm Detection Ind
No
Cpm Conf Ind
Yes
Investigation Status
No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate)
Investigation Status Details
A review of the accident determined that there were no control room actions that contributed to the event.
Employee Drug Test Ind
No
Contractor Drug Test Ind
No
Cause
Corrosion Failure
Cause Details
External Corrosion
Internal External
External Corrosion
Visual Exam Results
Localized Pitting
Galvanic Corrosion Ind
Yes
Field Exam Basis Ind
Yes
Underground Location
Yes
Under Cathodic Protection Ind
Yes
Cathodic Pro Start Year
1952
Shielding Evident
No
Cathodic Survey Type
Yes
Cp Annual Survey Ind
Yes
Close Interval Survey Ind
Yes
Cp Annual Survey Year
2022
Close Interval Survey Year
2019
Prior Damage
N/a Bare/ineffectively Coated Pipe
Collected Data Ind
Yes
Axial Magnetic Flx Lkg Ind
Yes
Geometry Deformation Ind
Yes
Axial Recent Year
2022
Axial Rcnt Propul Method
Free Swimming
Axial Rcnt Attuned Detect
Metal Loss
Axial Rcnt Atnd Dtct Metal
Standard Resolution
Axial Previous Year
2020
Axial Prev Propul Method
Free Swimming
Axial Prev Attuned Detect
Metal Loss
Axial Prev Atnd Dtct Metal
Standard Resolution
Geometry Recent Year
2022
Geometry Rcnt Propul Method
Free Swimming
Geometry Rcnt Resolution
Standard Resolution
Geometrt Rcnt Measur Cups
Inside Ili Cups
Geometry Previous Year
2020
Geometry Prev Propul Method
Free Swimming
Geometry Prev Resolution
Standard Resolution
Geometrt Prev Measur Cups
Inside Ili Cups
Has Hydrtst Conduc Before Ind
Yes
Hydrtst Most Rcnt Year
2013
Hydrtst Most Rcnt Pressure
1054
Direct Asmnt Conducted
No
Non Destructive Exam Ind
No
Preparer Name
T*** N*******
Preparer Title
Director - Regulatory Compliance
Preparer Email
T************@e*************.com
Preparer Telephone
713-989-7126
Prepared Date
2023-02-15 00:00:00
Authorizer Name
T*** N*******
Authorizer Telephone
713-989-7126
Authorizer Title
Director - Regulatory Compliance
Authorizer Email
T************@e*************.com
Narrative
On 10/10/2022 at 18:00, a farmer called in an approximate 20'x20' stain on the surface of the row. The control center shutdown the pipeline and operations local operations team was dispatched to the area and conducted a row inspection. The crew discovered a leak on the 12-inch corsicana to tyler line. Approximately 400 barrels of crude oil was released. The segment was isolated by closing manual block valves. The area was excavated and the leak source identified and examined it was determined the failure was caused from an external corrosion pinhole. A mechanical plidco clamp was installed at 21:35. On 10/13, the torque on clamp was re-verified and the line was restarted at 20:30. Cathodic protection potentials in the area were above required criteria. The most recent in line assessment identified external metal loss at the failure point below actionable levels. Updated information was supplied to the tool vendor and the run was regraded and is currently being revalidated. The pipeline is currently on a shortened integrity assessment frequency in order to more closely monitor corrosion growth rates. The failed section of pipe has been cut out and replaced.
| Report Received Date | 2022-11-09 00:00:00 |
|---|---|
| Iyear | 2022 |
| Report Number | 20220250 |
| Supplemental Number | 37716 |
| Report Type | Supplemental Final |
| Operator Id | 18718 PHMSA Enforcement |
| Name | Sunoco Pipeline L.p. |
| Operator Street Address | 1300 Main Street |
| Operator City Name | Houston |
| Operator State Abbreviation | TX |
| Operator Postal Code | 77002 |
| Local Datetime | 2022-10-10 18:00:00 |
| Time Zone | Central |
| Daylight Savings Ind | Yes |
| Location Latitude | 32.103628 Google Maps OpenStreetMap |
| Location Longitude | -96.280635 Google Maps OpenStreetMap |
| Commodity Released Type | Crude Oil |
| Unintentional Release Bbls | 400 |
| Recovered Bbls | 400 |
| Fatality Ind | No |
| Fatal | 0 |
| Injury Ind | No |
| Injure | 0 |
| Accident Identifier | Notification From Public |
| Incident Identified Datetime | 2022-10-10 18:30:00 |
| System Part Involved | Onshore Pipeline, Including Valve Sites |
| On Off Shore | Onshore |
| Status When Identified | Normal Operation, Includes Pauses Between Batches And During Maintenance |
| Shutdown Due Accident Ind | Yes |
| Shutdown Datetime | 2022-10-10 18:00:00 |
| Restart Datetime | 2022-10-13 20:30:00 |
| Communication State Fed Ind | Yes |
| Party Initiated Communication | Operator |
| Initial Responder Com Datetime | 2022-10-10 19:35:00 |
| On Site Datetime | 2022-10-10 18:30:00 |
| Confirmed Discovery Datetime | 2022-10-10 18:30:00 |
| Nrc Rpt Datetime | 2022-10-10 19:11:00 |
| Nrc Rpt Num | 1349534 NRC Report How to search |
| Additional Nrc Report Numbers | 1349728 |
| Ignite Ind | No |
| Upstream Action Taken | Valve Closure |
| Upstream Valve Close Datetime | 2022-10-10 18:45:00 |
| Upstream Valve Type Ind | Manual |
| Downstream Action Taken | Valve Closure |
| Downstream Vlv Close Datetime | 2022-10-10 18:55:00 |
| Downstream Valve Type Ind | Manual |
| Notify Qualified Indiv Ind | Yes |
| Qualified Indiv Notif Datetime | 2022-10-10 18:05:00 |
| Oil Spill Removal Org Ind | No |
| Num Pub Evacuated | 0 |
| Pipe Fac Name | Corsicana To Tyler |
| Segment Name | 26007 - 12-Inch Corsicana To Tyler Junction |
| Onshore State Abbreviation | Tx |
| Onshore Postal Code | 75110 |
| Onshore City Name | Not Within A Municipality |
| Onshore County Name | Navarro |
| Designated Location | Milepost |
| Designated Name | 84.5 |
| Federal | No |
| Location Type | Pipeline Right-Of-Way |
| Incident Area Type | Underground |
| Incident Area Subtype | Under Soil |
| Depth Of Cover | 10 |
| Crossing | No |
| Pipe Facility Type | Intrastate |
| Item Involved | Pipe |
| Pipe Type | Pipe Body |
| Puddle Weld Ind | No |
| Pipe Diameter | 12.75 |
| Pipe Wall Thickness | 0.25 |
| Pipe Smys | 30000 |
| Pipe Specification | Grade A |
| Pipe Seam Type | Single Saw |
| Pipe Manufacturer | Unknown |
| Pipe Coating Type | Coal Tar |
| Coating Applied Ind | No |
| Installation Year | 1931 |
| Manufactured Year | Unknown |
| Material Involved | Carbon Steel |
| Release Type | Leak |
| Leak Type | Pinhole |
| Wildlife Impact Ind | No |
| Soil Contamination | Yes |
| Long Term Assessment | No |
| Remediation Ind | Yes |
| Soil Remed Ind | Yes |
| Water Contam Ind | No |
| Could Be Hca | Yes |
| Commodity Reached Hca | No |
| Est Cost Oper Paid | 100000 |
| Est Cost Gas Released | 36800 |
| Est Cost Prop Damage | 0 |
| Est Cost Emergency | 21800 |
| Est Cost Environmental | 250000 |
| Est Cost Other | 0 |
| Prpty | 408600 |
| Num Persons Hosp Not Ovnght | 0 |
| Num Injured Treated By Emt | 0 |
| Num Resident Building Affctd | 0 |
| Num Business Building Affctd | 0 |
| Accident Psig | 350 |
| Mop Psig | 784 |
| Mop Cfr Section | Subpart E Pressure Test �195.406(A)(3) View CFR 49 §192 |
| Maop Established Date | 2013-03-27 00:00:00 |
| Maop Reversal Flow Ind | No |
| Accident Pressure | Pressure Did Not Exceed Mop |
| Pressure Restriction Ind | No |
| Length Segment Isolated | 56216 |
| Internal Inspection Ind | Yes |
| Operation Complications Ind | No |
| Pipeline Function | > 20% Smys Regulated Transmission |
| Scada In Place Ind | Yes |
| Scada Operating Ind | Yes |
| Scada Functional Ind | Yes |
| Scada Detection Ind | No |
| Scada Conf Ind | Yes |
| Cpm In Place Ind | Yes |
| Cpm Operating Ind | Yes |
| Cpm Functional Ind | Yes |
| Cpm Detection Ind | No |
| Cpm Conf Ind | Yes |
| Investigation Status | No, the operator did not find that an investigation of the controller(s) actions or control room issues was necessary due to: (provide an explanation for why the operator did not investigate) |
| Investigation Status Details | A review of the accident determined that there were no control room actions that contributed to the event. |
| Employee Drug Test Ind | No |
| Contractor Drug Test Ind | No |
| Cause | Corrosion Failure |
| Cause Details | External Corrosion |
| Internal External | External Corrosion |
| Visual Exam Results | Localized Pitting |
| Galvanic Corrosion Ind | Yes |
| Field Exam Basis Ind | Yes |
| Underground Location | Yes |
| Under Cathodic Protection Ind | Yes |
| Cathodic Pro Start Year | 1952 |
| Shielding Evident | No |
| Cathodic Survey Type | Yes |
| Cp Annual Survey Ind | Yes |
| Close Interval Survey Ind | Yes |
| Cp Annual Survey Year | 2022 |
| Close Interval Survey Year | 2019 |
| Prior Damage | N/a Bare/ineffectively Coated Pipe |
| Collected Data Ind | Yes |
| Axial Magnetic Flx Lkg Ind | Yes |
| Geometry Deformation Ind | Yes |
| Axial Recent Year | 2022 |
| Axial Rcnt Propul Method | Free Swimming |
| Axial Rcnt Attuned Detect | Metal Loss |
| Axial Rcnt Atnd Dtct Metal | Standard Resolution |
| Axial Previous Year | 2020 |
| Axial Prev Propul Method | Free Swimming |
| Axial Prev Attuned Detect | Metal Loss |
| Axial Prev Atnd Dtct Metal | Standard Resolution |
| Geometry Recent Year | 2022 |
| Geometry Rcnt Propul Method | Free Swimming |
| Geometry Rcnt Resolution | Standard Resolution |
| Geometrt Rcnt Measur Cups | Inside Ili Cups |
| Geometry Previous Year | 2020 |
| Geometry Prev Propul Method | Free Swimming |
| Geometry Prev Resolution | Standard Resolution |
| Geometrt Prev Measur Cups | Inside Ili Cups |
| Has Hydrtst Conduc Before Ind | Yes |
| Hydrtst Most Rcnt Year | 2013 |
| Hydrtst Most Rcnt Pressure | 1054 |
| Direct Asmnt Conducted | No |
| Non Destructive Exam Ind | No |
| Preparer Name | T*** N******* |
| Preparer Title | Director - Regulatory Compliance |
| Preparer Email | T************@e*************.com |
| Preparer Telephone | 713-989-7126 |
| Prepared Date | 2023-02-15 00:00:00 |
| Authorizer Name | T*** N******* |
| Authorizer Telephone | 713-989-7126 |
| Authorizer Title | Director - Regulatory Compliance |
| Authorizer Email | T************@e*************.com |
| Narrative | On 10/10/2022 at 18:00, a farmer called in an approximate 20'x20' stain on the surface of the row. The control center shutdown the pipeline and operations local operations team was dispatched to the area and conducted a row inspection. The crew discovered a leak on the 12-inch corsicana to tyler line. Approximately 400 barrels of crude oil was released. The segment was isolated by closing manual block valves. The area was excavated and the leak source identified and examined it was determined the failure was caused from an external corrosion pinhole. A mechanical plidco clamp was installed at 21:35. On 10/13, the torque on clamp was re-verified and the line was restarted at 20:30. Cathodic protection potentials in the area were above required criteria. The most recent in line assessment identified external metal loss at the failure point below actionable levels. Updated information was supplied to the tool vendor and the run was regraded and is currently being revalidated. The pipeline is currently on a shortened integrity assessment frequency in order to more closely monitor corrosion growth rates. The failed section of pipe has been cut out and replaced. |
External Resources
PHMSA pipeline safety insights.
Product
Features
Company
All rights reserved. Copyright © by ClearPHMSA